Search published articles


Showing 8 results for Sakineh

Masoomeh Hasani Tabatabaie, Ayob Pahlavan, Esmaiel Yasini, Mansore Mirzaie, Sakineh Arami, Hamid Kermanshah, Hamidreza Sadeghipour Roudsari, Seyed Hossein Bassir, Taher Akbari Saeed, Hamed Hasani,
Volume 25, Issue 3 (1 2012)
Abstract

Background and Aims: There is concern that leached components from dental composites may cause adverse changes in the reproductive health. This study aimed to assess the effects of leached components from a hybrid resin composite on the reproductive system of male mice.
Materials and Methods: In the present animal study, twenty adult Syrian male mice were divided into two groups of 10 mice each. In the test group, components which leached from samples made from Filtek Z250 resin composite into 75% ethanol were daily administered to the mice for 28 days. In the control group, the procedure was repeated in the same way as the test group but without placing composite samples in the solution. Then, the body weight, weights of paired testes, Gonado Somatic Index, sperm viability, sperm motility, epididymal sperm reserve and daily sperm production were recorded. Four male mice in each group were mated with untreated female mice for 10 days. After that, the number of pregnant females and number of infants were recorded. The data were analyzed using repeated measures ANOVA, Chi-square test and t-test.
Results: There was a significant reduction in the sperm viability and sperm motility of male mice in the test group compared to the control group (P=0.001). There was no any significant differences in other parameters between two groups (P>0.05).
Conclusion: This study showed that the leached components from resin composites cannot cause infertility but they could potentially cause some adverse effects on the reproductive system of male mice.


Ayob Pahlavan, Masumeh Hasani Tabatabaei, Sakineh Arami, Mohammad Ataie, Sara Valizadeh,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: Polymerization shrinkage in Methacrylate-based composite is one of the most important factors in composite restorations failure. Silorane-based composite is introduced to compensate this drawback and claimed to have low shrinkage. The aim of this study was to evaluate the polymerization shrinkage of these two composites.

Materials and Methods: In this experimental study, 5 disk shape samples for each resin composites were placed in the centre of metallic ring bonded to microscopic glass slab. Top surface of ring was covered by a glass cover slip. Glass slab and sample were placed on a special LVDT holder in order to light cure from bottom surface and to measure the polymerization shrinkage. In this study, Deflecting Disk method and LVDT (linear variable differential transducer) was used for dimensional change measurement of resin composites. In this study, two LED curing units were used for composite polymerization.

Results: The mean of polymerization shrinkage in Z250 cured with LED and High Power LED was 11.15±0.08µm and 11.51±0.17µm, respectively (P=0.094), and in P90 cured with LED and High Power LED was 1.08±0.06µm and 1.16±0.12µm, respectively (P=0.019).

Conclusion: Silorane-based composite (P90) showed significantly less polymerization shrinkage than that of methacrylate-based composite (Z250). For the two types of composite, there was no significant difference between the two curing units in polymerization shrinkage.


Sakineh Nikzad, Abbas Azari, Mani Arashrad, Ghazal Arashrad,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: The marginal integrity of fixed restorations always is a major matter of concern for dental clinicians. Any cause of distortion, including veneering processes, in the marginal integrity is supposed to be detrimental for long-term success of fixed dental prostheses. The aim of this in vitro study was to compare the marginal adaptation of two different full ceramic restoration systems (Zirkouzahu&Cercon) and possible changes in marginal integrity following the multiple veneering process.

Materials and Methods: Twelve all-ceramic crowns in the form of coping were fabricated on a pre-made standard metal die with finish line of shoulder preparation from two commercial systems: Cercon® and Zirkonzahn®. The specimens were not cemented. The Crown/Die discrepancy were measured by means of a precise stereo microscope (accuracy±0.1 μm), at various points (n=12) selected along circumferential margin of the restorations. Same procedure was accomplished after applying the veneering porcelain. The mean gap dimensions were calculated and data were analyzed by multivariate (b) test.

Results: Mean marginal gap dimensions before and after veneering porcelain firing cycles, for Cercon® were (59.67±13.46 µm) and (63.75±14.16 µm) and for Zirkonzahn® were (65.81±24.37 µm) and (64.74±21.94 µm), respectively. Hotelling trace Multivariate(b) test method showed that the rate of mismatching marginal integrity in two groups (Cercon® and Zirkonzahn®) had no significant difference before and after porcelain firing (P>0.05).

Conclusion: Within the limitation of this study, the marginal integrity of both systems were seems to be within the clinically acceptable standard dimension, i.e. 120μm.The marginal gap of both all-ceramic systems were not affected by veneering porcelain firing cycles.


Sakineh Nikzad, Abbas Azari, Somayeh Niakan, Zeynab Bahrani,
Volume 27, Issue 3 (9-2014)
Abstract

  Background and Aims: The aim of this review article was to present the information have been published, regarding the functional properties of Zirconia until today.

  Materials and Methods: A review of the literature was carried out in MEDLINE database using key words (Dental ceramic, Zirconia, 3Y-TZP, Clinical performance, Machining and Transformation toughening). These searches were limited to the articles published after the year 2000.

  Conclusion: Despite excellent clinical results in short-term studies, there is still a major need to have more clinical and laboratory long-term information about zirconia restorations.


Arami Sakineh , Aghasadeghi Mohamadreza , Tabatabaie Masome Hasani , Darvishpour Hojat , Sheikhzadeh Sedigheh ,
Volume 27, Issue 4 (1-2015)
Abstract

  Background and Aims: Hepatitis B is an important infection route in dentistry requiring different disinfectants to prevent its transmission. The aim of this study was to compare the effects of chemical disinfectants (FD366, ISORAPID and 5% sodium hypochlorite 2/100) to remove Hepatitis B infections from the dental surfaces.

  Materials and Methods: In this experimental laboratory trial, serum of 10 HBV patients was poured into microtubes, FD366, ISORAPID and hypochlorite disinfectants were added to them. PCR experiments with viral diagnostic kits were used to diagnose the virus genome. Real time PCR was used to evaluate after incubation with the disinfectants. The reductions occurred in the viral load of Hepatitis B were statistically analyzed using Kruskal-wallis and Mann-Whitney U tests .

  Results: No significant antiviral efficacy was noted following the application of FD366 and ISORAPID disinfectants (P=0/07). However, hypochlorite showed the most efficacy to disinfect Hepatitis B and a significant difference was found among them (P<0.0001).

  Conclusion: Under the study limitations, FD366 and ISORAPID disinfectants did not show adequate efficacy to remove Hepatitis B virus. Hypochlorite was the most effective disinfectant.


Masumeh Hasani Tabatabaei, Sakineh Arami, Fatemeh Khajavi, Zohreh Moradi,
Volume 29, Issue 4 (1-2017)
Abstract

Background and Aims: Despite the reduction of incidence of dental caries in recent years, this disease is common and many efforts were conducted to decrease the prevalence of dental caries. On the other hand secondary caries lesions are the main reason for replacement of direct restorations. Therefore, the aim of the current study was to evaluate suitable methods of preparation and restorative materials to reduce caries recurrence.

Materials and Methods: In this experimental study, eighty human teeth were collected and stored in normal saline. The teeth were soft-tissue debrided and cleaned with water/pumice slurry and rubber cups in a low-speed handpiece. Speciments were randomly divided in two main groups. Cavities were prepared with diamond burs or Er:YAG laser (10 Hz, 300 mJ, 3W). Each group was divided into 4 sub-groups, and restored with a glass-ionomer cement (Fuji IX), resin modified glass-ionomer (Fuji II LC), total etch bonding + composite resin or self-etch bonding + composite resin. The specimens were submitted to pH cycling. Speciments were then sectioned, polished and Vickers microhardness measurements were performed on each specimen. Differences among the medians were analyzed using two way ANOVA test at a 95% confidence level and Tukey test.

Results: Statistical analysis showed significant difference in the type of substrate (enamel, dentin) in both main groups (P<0.0001) but no differences in the caries lesion development between the cavities restored with the same material and prepared with diamond burs or Er:YAG laser.

Conclusion: The Er:YAG laser used for cavity preparation and different types of restorative materials used did not show the ability to guarantee significantly more acid-resistance tooth structure against demineralization.


Sakineh Arami, Sakineh Arami, Masoumeh Hasani Tabatabaei, Seyed Reza Najafzadeh, Ahmadreza Shamshiri, Zohreh Moradi,
Volume 30, Issue 4 (1-2018)
Abstract

Background and Aims: According to many uses of MTA in different treatments, studying about its properties like the setting time, is of great importance. The aim of this study was to compare the initial and final setting time of an Iranian MTA and a foreign MTA.
Materials and Methods: Seven samples were in each group; for measurement of initial and final setting time of MTAs, a mold with dimension of 2×10 mm was prepared. The cements after mixation were put into an incubator with temperature of 37C and humidity of 90%. After mixing of cements, a Gilmore needle with a weight of 100 gr and active tip of 2 mm was used vertically on the surface of MTA for measurement of the initial setting time. Setting was measured by the start of cement mixation to the time the tip of the needle didn’t penetrate to the surface of MTA. For measurement of the final setting time a Gilmore needle with a weight of 456 gr and active tip of 1mm was used vertically on the surface of MTA. The ANOVA test followed by Tukey test was used for comparison of the mean setting time between an Iranian and foreign MTA. The statistical difference was considered significant at the level of 0.05.
Resultes: The mean initial setting time Angelus and Root MTAs were 13.57±0.91 and 11.14±0.92 min, the mean final setting of Angelus and Root MTA, were 48.93±1.54 and 37.86±1.5 min while the initial setting time of Angelus MTA lasted for 0.53±43.2 more min than Root MTA (P=0.001). The final setting time of Angelus MTA took longer for 110.7±0.82 min than Root MTA (P=0.001).
Conclusion: The initial and final setting time of the Iranian MTA was shorter than the foreign one and thus it could a more alternative option in this respect.

Shiva Shirazian, Sakineh Nikzad Jamnani, Maryam Memarian, Homa Shaghi,
Volume 33, Issue 1 (7-2020)
Abstract

Background and Aims: Due to the very high importance of assessing the clinical performance of students, choosing the best assessment tool and method is one of the most important goals and tasks in medical education. The objective of this study was the development of a checklist for the assessment of dental students’ clinical skills of Tehran University of Medical Sciences, in the clinical complete denture course. The second aim was to determine the validity and reliability of the checklist, and The third aim was the evaluation of raters’ and students’ satisfaction.
Materials and Methods: The checklist was developed in expert panel sessions, and the validity and reliability of the checklist were assessed with CVI (content validity index) test-retest and inter-rater reliability methods, respectively. Students (n=15) were evaluated with a developed checklist. At the end of the session, the satisfaction level of staff and students were assessed. The obtained information was reported descriptively with the expression of mean and standard deviation and in the form of relative and absolute frequencies.
Results: The content validity index (CVI) of the checklist was 0.96. The reliability of the checklist confirmed with a high Intraclass Correlation Coefficient (>0.8) (between 0.82-0.97) (P<0.05). The coefficient of agreement in inter-rater reliability was 0.99 (between 0.991-0.998). Raters’ and students’ satisfaction earned a high percentage of satisfaction.
Conclusion: The designed checklist has the optimal features of a good students’ clinical performance assessment tool; it seems that using this checklist can be an excellent alternative method to a global rating scale to assess the clinical skills of dental students in the complete denture courses.


Page 1 from 1     

© 2026 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb