Search published articles


Showing 5 results for Zeighami

Naser Golshah, Habib Hajimiragha, Saeed Nokar, Somayeh Zeighami,
Volume 25, Issue 1 (7 2012)
Abstract

Background and Aims: Since a large marginal opening allows more plaque accumulation, gingival sulcular fluid flow and bone loss, microleakage, recurrent caries and periodontal disease, marginal fit is of great importance in fixed restorations. The aim of this study was to compare the marginal fit of zirconium-based all ceramic (Cercon) frameworks, made by two different approaches (Direct and Wax-up scanning).

Materials and Methods: An abutment analog, with 5.5 mm width and height, was selected as an experimental model. Twenty all ceramic cores were made for this model (10 specimens per each group). In the first group (Direct), experimental models were scanned directly using Computer Aided Design/Computer Aided Manufacturing (CAD/CAM). The core was then designed with the aid of a computer and machined. In the second group (Wax-up or CAM) a wax-up pattern was made on the experimental model and then scanned and milled from Cercon blocks. The marginal discrepancy of each specimen was recorded using a stereomicroscope (SZX9, Olympus, Japan) and digital camera (Mode TK, C1380E, JVC, Japan) and then measured by Adobe Photoshop CS software. The data were analyzed using T-test.

Results: Mean marginal discrepancy of Direct group (85.2±3.95 µm) was significantly less than that of Wax-up group (120.2±6.91 µm).

Conclusion: Improved marginal fit of zirconia ceramics was found with the direct model scanning compared with that of Wax-up scanning using CAD/CAM.


Somayeh Zeighami, Hakimeh Siadat, Marzieh Alikhasi, Zeinab Saeidi,
Volume 30, Issue 1 (6-2017)
Abstract

Background and Aims: Taking impression from angulated implants has always been a great challenge in clinic. In this regard, studies on sectional trays are very few. The aim of this study was to evaluate and compare the dimensional and angular accuracy of impressions using full arch and sectional trays.

Materials and Methods: Four implants (4.3 × 12 mm) (Implantium, Dentium) were placed in the first premolar and molar regions of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty open special trays (Full arch & Sectional) were made on the primary cast. The impressions were taken using vinyl polysiloxane (VPS) and were poured with type IV dental stone. The coordinate measuring machine (CMM) was used to measure the dimensional (Z, Y, X) and angular (θ) coordinates of implants. The data were analyzed using and t-test and SPSS 22. Software.

Results: The type of tray had no significant effect on the dimensional accuracy in X, Y and Z axes (P>0.05) and total linear displacement (r); However, it significantly affected the angular accuracy (∆q) (P<0.05).

Conclusion: Sectional tray yields less rotational displacement in impressions made of angulated implants.


Elham Zajkani, Habib Zeighami, Alireza Zaeefjou,
Volume 30, Issue 1 (6-2017)
Abstract

Background and Aims: Dental caries is an infectious disease transmitted by multiple factors in the mouth and one of the most common chronic diseases in the world that requires a lot of treatment expenses. The aim of this study was to evaluate the effect of fluoride 0.2% and Fuchs mouthwash (a combination of xylitol and fluoride 920 ppm) against two bacterial growths (Streptococcus mutans and Lactobacillus acidophilus).

Materials and Methods: In this in vitro study, first the well diffusion method and then MIC method (minimum inhibitory concentration) were used. Data were analyzed with Excell (2016).

Results: The results of the MIC method showed inhibitory effect of both mouthwashes in pure concentration (128 μg/ml). However, fluoride was effective in concentration higher than 32 μg/ml for Streptococcus mutans and higher than 2 μg/ml for lactobacillus acidophilus. Fuchs was effective for both bacteria at concentration higher than 64 μg/ml and in lower concentration it was ineffective. The results of the well diffusion test showed the inhibition of fluoride mouthwash in pure concentration on the Streptococcus mutans was (17 mm) and on the lactobacillus acidophilus 24 mm was obtained. In Fuchs mouthwash was zero and it represented effectiveness of fluoride on bacteria and ineffectiveness of Fuchs.

Conclusion: The fluoride mouthrinse in different concentrations, because of having a good inhibitory effect in both methods on Streptococcus mutans and Lactobacillus acidophilus was more effective compared with that of Fuchs mouthrinse.


Somayeh Zeighami, Marzieh Alikhasi, Maryam Memarian, Moeen Hosseini Shirazi,
Volume 30, Issue 4 (1-2018)
Abstract

Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutments after cyclic loading.
Materials and Methods: 10 castable abutments were cast in Co-Cr alloy with similar size and height. Each specimen was mounted vertically on a separated implant using a 30 Ncm tightening torque. The detorque values of the abutments were evaluated after 10 min. The same tightening torque was applied to the abutments on their corresponding implants and cyclic loading was applied for 500,000 cycles to the implant-abutment assembly. The torque values after cyclic loading were recorded for each specimen. T-test analysis was conducted on scores from the groups.
Resultes: The results of this study showed that the percentage of torque loss in castable abutments was significantly increased after cyclic loading (P<0.001).
Conclusion: Misfit between the castable implant components can cause torque loss before and after cyclic loading. However, it is more appropriate to relate the results of this study to the screw loosening of the above mentioned abutments than judging their clinical performance.

Pooya Jannati, Faranak Vakili, Saeid Nokar, Somayeh Zeighami,
Volume 36, Issue 0 (5-2023)
Abstract

Background and Aims: Endocrown is a type of monoblock restoration using the pulp chamber and remaining coronal tooth structure for retention. Advancements in adhesive techniques have breathed fresh spirit into endocrown. Nowadays, there are two approaches for endocrown: conventional approach and  biomimetic approach. This study aimed to review data on the steps and clinical and philosophical points of using these approaches to help dentists’ selection and performance.
Materials and Methods: The review was conducted by reviewing the articles available in PubMed, Scopus, and Google Scholar databases from 1995 to 2022. The keywords used were; Crown, Endodontically-treated teeth, Light-curing of dental adhesive, Onlay, and Post-Core.  
Results: After removing duplicates, titles/abstracts were reviewed. Animal studies, studies without available full text or non-English language studies were excluded from the study. Then, the full texts of the remaining 59 articles were evaluated and 49 articles were eligible for the present study. The articles included clinical trials, in vitro, systematic reviews, and case reports.
Conclusion: Endocrown is a successful alternative to crown, especially in molar teeth. Regardless of the conventional or biomimetic approach, this treatment has a more favorable fracture pattern while preserving the remaining tooth tissue as much as possible.


Page 1 from 1     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb