Search published articles


Showing 54 results for Resin

L. Ghahramani, S. Shahabi, A. Amirjan, A Fazel,
Volume 23, Issue 4 (1-2011)
Abstract

Background and Aims: Failure of bonding between artificial teeth and denture base material is a considerable problem for patients who wear dentures. Because of the cost of denture repair and the expensive price of foreign artificial teeth, this study was designed to compare the bond strength of composite and acrylic artificial teeth with heat-cured and auto-polymerized denture base resins.
Materials and Methods: In this experimental and in vitro study, two type of acrylic resin (heat-cured: Selectaplus H/ Trevalon, Dentsply and auto-polymerized: Rapid Repair, Dentsply) and four artificial teeth (acrylic Marjan New, composite Glamour teeth which both of them are Iranian) and Ivoclar acrylic and composite teeth were used. Therefore, 8 groups of 14 specimens each were evaluated. A shear bond strenghth test in a Universal Testing Machine was used. Data were analyzed using the 2-way ANOVA test.
Results: The bond strengths of acrylic teeth (Marjan New and Ivoclar) to heat-cured resin were similar (P=0.632) and statistically higher than those of composite teeth (Glamour and Ivoclar). Acrylic teeth (Marjan New and Ivoclar) and Glamour teeth had similar bond strength to auto-polymerized resin, which showed the highest bond strength values. Ivoclar composite teeth showed significantly the lowest bond strength (P<0.05). All acrylic teeth had the highest mean bond strengths to heat-cured resin which were significantly different from that of
auto-polymerized resin (P<0.05). However, the bond strengths of all composite teeth to both denture base resins were not significantly different (P>0.05).
Conclusion: Based on the results of this study, the type of denture base material and artificial tooth may influence the failure load.


Aa. Soleymani, Z. Bahrololoomi, S. Parkam,
Volume 24, Issue 1 (3-2011)
Abstract

Background and Aims: Dentin contamination with different materials used in pediatrics is effective on the bond strength of adhesives to primary teeth. Therefore, the purpose of this in vitro study was to evaluate the effect of zinc oxide-eugenol and formocresol on the shear bond strength (SBS) of resin composite to the dentin in primary teeth.

Materials and Methods: A total of 72 extracted second morals were selected and mounted in acrylic resin. Buccal and lingual dentin surface were prepared and randomly allocated into 4 groups of 18 specimens each. Groups were subjected to different treatments as follows: group A, the surfaces were received no pretreatment and served as control group B, the surfaces were covered with a paste of ZOE (Zoliran) group C, the surfaces were covered with a paste of ZOE (Kemdent) group D, specimens were placed on gauze soaked in formocresol. The specimens were covered with tinfoil and stored in distilled water at 37oC for 7 days. The temporary restorations were removed after one week. The dentin surfaces were treated with single bond adhesive resin 3M (ESPE/USA) according to manufacturer’s instructions and light cured for 20 seconds. Composite P60 columns (4 mm internal diameter and 3 mm height) were applied on the prepared surfaces and light cured for 40 seconds. Shear bond testing were carried out after 24 hours with a cross head speed of 0.5 mm/min. Statistical analysis was conducted using one- way ANOVA and Tukey Post-hoc test.

Results: The mean shear bond strengths were 17.52±3 MPa for group A, 15.41±3.3 MPa for group B, 15.63±3.2 MPa for group C, and 18.57±3.8 MPa for group D. There was no significant difference between the shear bond strength of group A compared with those of groups B, C, and D (P>0.05).

Conclusion: The bond strength of composite to dentin in primary teeth was not influenced by the zinc-oxide eugenol (Zoliran & Kemdent) or formocreosol.


E. Yasini, H. Kermanshah, M. Mirzaie, B. Ranjbar Omidi,
Volume 24, Issue 3 (6-2011)
Abstract

Background and Aims: Marginal seal in class V cavities and determining the best restorative material to decrease microleakage is of great importance in operative dentistry. The aim of this study was to evaluate the effect of polishing time on the microleakage of three types of tooth-colored restorative materials in class V cavity preparations and to assess the marginal integrity of these materials using scanning electron microscope (SEM).
Materials and Methods: In this in vitro study, class V cavity preparations were made on the buccal and lingual surfaces of 30 bovine incisors (60 cavities). The specimens were divided into three groups each containing 10 teeth (20 cavities): group 1, Filtek Z350 (nanocomposite) group 2, Fuji IX/G Coat Plus (CGIC) and group 3, Fuji II LC (RMGI). In each group, half of the specimens (n = 20) were finished/polished immediately and the rest of them were finished/polished after 24 hours. All the specimens were thermocycled for 2000 cycles (5-50 °C). Epoxy resin replicas of 12 specimens (2 restorations in each subgroup) were evaluated using SEM and the interfacial gaps were measured. Finally, the teeth were immersed in 0.5% basic fuchsin dye for 24 hours at room temperature, sectioned and observed under stereomicroscope. The data were analyzed using Kruskal-Wallis and Mann-Whitney U tests and the comparison between incisal and cervical microleakage was made with Wilcoxon test.
Results: Incisal and cervical microleakage were not affected by polishing time in none of the three restorative materials (P>0.05). Cervical microleakage only in Fuji IX with immediate polishing was significantly higher than incisal microleakage (P<0.05). Incisal and cervical microleakage with immediate or delayed polishing were not significantly different in Fuji IX, Fuji II LC, and Z350 (P>0.05).
Conclusion: Immediate polishing is recommended in tooth-colored class V restorations.


Alireza Heidari, Mehdi Shahrabi, Sara Ghadimi, Shahram Mosharafian, Hosein Ansari, Zohreh Rafiee,
Volume 25, Issue 2 (4-2012)
Abstract

Background and Aims: Using the conservative adhesive resin restoration (CAR) in uncooperative children lead to numerous problems because of being time consuming. The purpose of this study was to compare the microleakage of conservative adhesive resin restoration under separate curing and co-curing.

Materials and Methods: In this experimental study, 120 intact premolar teeth were collected and 120 vertical grooves were prepared on them. Then the teeth were divided into four groups: group 1, separated curing of bonding agent, flowable composite and sealant group 2, co-curing of all materials for 60 seconds group 3,
co-curing of all materials for 40 seconds and group 4, co-curing of all materials for 20 seconds. Then the specimens were thermocycled and immersed in basic fuchsin solution. The teeth were sectioned horizontally and dye penetration was evaluated with stereomicroscope. Date were analyzed using one-way ANOVA and Scheffe test.

Results: Mean value of dye penetration in groups 1, 2, 3, and 4 was 1.53±0.6, 2.06±0.6, 2.5±0.7 and 3.53±0.6, respectively. There was a statistically significant difference between group 1 and the other groups (P=0.0001).

Conclusion: Considering the problems caused by microleakage in conservative resin adhesive restorations, co-curing method should not be used. In the case of using co-curing method, 60 second curing time is suggested for sufficient polymerization.


Tahereh Sadat Jafarzadeh Kashi, Mohammad Erfan, Akbar Fazel Najafabadi, Seied Mostafa Fatemi, Marjan Behroozibakhsh, Haleh Hali, Hosein Bagheri Gorgani,
Volume 25, Issue 2 (4-2012)
Abstract

Background and Aims: The aim of this study was to measure the degree of conversion (DC) of three types of composite resins (micro-hybrid, nano-hybrid and Ormocer) with different light curing units (LED LCU and QTH LCU) in two depths.

Materials and Methods: Three commercially available dental resin composites were used in this study: (Tetric Ceram, Ivoclar Vivadent, Liechtenstein-A2 shade), (Tetric Evoceram, Ivoclar Vivadent, Liechtenstein-A2 shade), (Ceram X, Dentsply, Germany-M2 shade). Specimens were divided into two groups, 5 specimens were photo-activated by QTH unit (Coltolux 75-Colten) and the other five specimens were cured by LED (Demi-Kerr). Then each specimen was sectioned at the top surface and at 2-mm depth. The DC was measured by FT-IR
(Bruker-tensor 27). The data were analyzed by 3-way ANOVA test.

Results: There was significant difference between tested composite resins (P<0.001). The results of top surfaces were significantly different from those observed at 2-mm depth (P<0.001). The type of curing unit affected the polymerization of Ceram X resin composite.

Conclusion: This study showed a significant difference in the degree of conversion in different thicknesses within three groups of resin composites.


Azita Kaviani, Fateme Asareh,
Volume 25, Issue 3 (7-2012)
Abstract

Background and Aims: Although composite resin restorations have many advantages, they can lead to several clinical problems. The primary reason for these problems is microleakage. The aim of this study was to compare the rebonding effect on microleakage of class V composite restorations using two low viscosity resins.
Materials and Methods: In this in vitro study, 60 class V composite restorations were performed in buccal and lingual surfaces of human extracted premolars with the occlusal margin in enamel and the gingival margin in dentin/cementum. The teeth were randomly divided into 3 groups: (I) restorations with no rebonding, (II) restoration margins rebonded with an enamel adhesive (Margin Bond), (III) restoration margins rebonded with a specific unfilled resin. The specimens were then thermocycled and immersed in 0.5% fuchsin dye solution. The samples were sectioned longitudinally and observed under a stereomicroscope for assessment of microleakage. The data were analyzed by Kruskal-Wallis, Wilcoxon and Mann-Whitney tests. P<0.05 was considered as the level of significance.
Results: Statistical analysis showed a significant difference in the microleakage of gingival margins (P<0.0001), but not in enamel margins (P=0.148). Microleakage at the gingival margins of group (III) was significantly less than that of group (II). Group (I) showed the highest amount of microleakage.
Conclusion: Rebonding by a low viscosity resin reduces microleakage at the gingival margins of class V composite restorations, but has no significant effect on the occlusal margins.


Masoomeh Hasani Tabatabaie, Ayob Pahlavan, Esmaiel Yasini, Mansore Mirzaie, Sakineh Arami, Hamid Kermanshah, Hamidreza Sadeghipour Roudsari, Seyed Hossein Bassir, Taher Akbari Saeed, Hamed Hasani,
Volume 25, Issue 3 (7-2012)
Abstract

Background and Aims: There is concern that leached components from dental composites may cause adverse changes in the reproductive health. This study aimed to assess the effects of leached components from a hybrid resin composite on the reproductive system of male mice.
Materials and Methods: In the present animal study, twenty adult Syrian male mice were divided into two groups of 10 mice each. In the test group, components which leached from samples made from Filtek Z250 resin composite into 75% ethanol were daily administered to the mice for 28 days. In the control group, the procedure was repeated in the same way as the test group but without placing composite samples in the solution. Then, the body weight, weights of paired testes, Gonado Somatic Index, sperm viability, sperm motility, epididymal sperm reserve and daily sperm production were recorded. Four male mice in each group were mated with untreated female mice for 10 days. After that, the number of pregnant females and number of infants were recorded. The data were analyzed using repeated measures ANOVA, Chi-square test and t-test.
Results: There was a significant reduction in the sperm viability and sperm motility of male mice in the test group compared to the control group (P=0.001). There was no any significant differences in other parameters between two groups (P>0.05).
Conclusion: This study showed that the leached components from resin composites cannot cause infertility but they could potentially cause some adverse effects on the reproductive system of male mice.


Azita Kaviani, Asadoallah Ahmadzadeh, Maryam Zarei,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: Discoloration of resin composites is considered to be the major factor in esthetic restoration failures. The aim of this study was to evaluate the color stability of resin composites after rebonding with two different adhesive materials.

Materials and Methods: Forty five composite disc samples were divided into three groups (n=15). The surface of specimens was finished by polishing disc and rubber. In group 1, any additional phase was not performed. In group 2, composite discs were etched by %37 orthophosphoric acid, then Margin- bond was used for rebonding. In group 3, the etching procedure was in the same manner used for group 2, but Permaseal was used after etching. After the first phase of spectrophotometric measurement, the specimens were dipped in coffee mix for 3 weeks for aging the specimens. Then the second phase of spectrophotometric evaluation was performed. Collected data was analyzed using one-way ANOVA test followed by Tukey test. P<0.05 was considered as the level of significance.

Results: The mean total color difference (∆E) observed in groups 1 to 3 were 1.4±0.34, 5.24±1.51, and 7.44±1.34, respectively. Statistical significant differences were shown between the groups (P<0.001).

Conclusion: Rebonding with adhesive materials used in this study did not increase the color stability of composite restorations.


Ayob Pahlavan, Masumeh Hasani Tabatabaei, Sakineh Arami, Mohammad Ataie, Sara Valizadeh,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: Polymerization shrinkage in Methacrylate-based composite is one of the most important factors in composite restorations failure. Silorane-based composite is introduced to compensate this drawback and claimed to have low shrinkage. The aim of this study was to evaluate the polymerization shrinkage of these two composites.

Materials and Methods: In this experimental study, 5 disk shape samples for each resin composites were placed in the centre of metallic ring bonded to microscopic glass slab. Top surface of ring was covered by a glass cover slip. Glass slab and sample were placed on a special LVDT holder in order to light cure from bottom surface and to measure the polymerization shrinkage. In this study, Deflecting Disk method and LVDT (linear variable differential transducer) was used for dimensional change measurement of resin composites. In this study, two LED curing units were used for composite polymerization.

Results: The mean of polymerization shrinkage in Z250 cured with LED and High Power LED was 11.15±0.08µm and 11.51±0.17µm, respectively (P=0.094), and in P90 cured with LED and High Power LED was 1.08±0.06µm and 1.16±0.12µm, respectively (P=0.019).

Conclusion: Silorane-based composite (P90) showed significantly less polymerization shrinkage than that of methacrylate-based composite (Z250). For the two types of composite, there was no significant difference between the two curing units in polymerization shrinkage.


Fateme Nematollahi, Nasim Azizi, Sima Shahabi, Loghman Ghahremani, Zohre Asgari, Hossein Bagheri ,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Failure of bonding between artificial teeth and denture base material is a considerable problem for patients who wear dentures. According to the different impact of artificial teeth and different information about resistance force of mastication and also with deficiency in researchs, this study was designed to compare the bond strength of composite and acrylic artificial teeth to auto-polymerized denture base resins with and without cyclic loading.

Materials and Methods: In this experimental and in vitro study, an acrylic resin auto-polymerized (Rapid Repair, Dentsply) and four artificial teeth (Acrylic Marjan new, Composite Glamour teeth and Ivoclar acrylic and composite teeth) were used. Therefore, 8 groups of 10 specimens each were evaluated. All specimens were thermocycled for 5000 cycles, in water baths between 5 and 55 C. Half the specimens in each group were treated with cyclic loading at 50N for 14, 400 cycles at 1.2 Hz. The shear bond strengths were measured using a Universal Testing Machine. Data were analyzed using Two-way ANOVA test.

Results: Statistical analysis demonstrated no significant effect of cyclic loading on the shear bond strength, but the type of artificial tooth affected the shear bond strength (P=0.006). Also, the interaction between Cyclic loading and the type of artificial tooth showed no significant difference (P=0.98). Tukey test showed that acrylic teeth (Ivoclar) had statistically higher bond strength values than that of other teeth (PGlamour=0.02), (PComposite ivoclar=0.01) and (PMarjan new=0.02).

Conclusion: Within the limitation of this study, the predominant type of fracture in all groups was cohesive, therefore the bond strength was adequate in all teeth and the type of artificial tooth may influence the bond strength of denture teeth to denture base resin. Cyclic loading had no significant effect on the bond strength of denture teeth to the auto-polymerized acrylic resin.


Lelya Sadighpour, Sousan Mir Mohammad Rezaei, Hamid Jalali, Shadab Rashtak,
Volume 26, Issue 4 (1-2014)
Abstract

  Background and Aims: Retention and stability of the post and core system is the key factor for success of final restoration . The aim of this study was to evaluate the microtensile bond strength of the different composite core materials and bonding systems to a fiber post.

  Materials and Methods: To evaluate the bond strength of the composite resins to a fiber post ( DT light post) 60 posts were divided into six groups : group A: Heliomolar Flow + Seal Bond, group B: Heliomolar Flow + SE Bond , group C: Valux Plus + Seal Bond , group D: Valux Plus + SE Bond , group E: Corecem + Seal Bond, group F: Corecem + SE Bond. All samples were thermocycled for 5000 cycles (5-55 0C) and cut into four bars for the microtensile bond strength test. Failure modes were identified using a stereomicroscope. Data were analysed using One-way ANOVA and Tukey HSD post hoc test (P<0.05).

  Results: The interaction between composite resin materials and bonding systems were positive. The conventional hybrid composite (Valux Plus) had significantly higher bond strength compared with the core specific flowable composite (Corecem) when Seal Bond was applied as bonding agent (P<0.05). However, when SE Bond was utilized hybrid composite demonstrated significantly lower bond strength than that of other two groups (P<0.05).

  Conclusion: The performance of a particular composite is affected by the bonding system that is applied. A single composite resin may have different bond strength when combined with different bonding system.


Zahra Jaberi Ansari, Mahdieh Daneshmonfared, Haleh Valizadeh Haghi,
Volume 27, Issue 1 (4-2014)
Abstract

  Background and Aims : In this in vitro study, the long-term bond strength of a self-adhesive resin cement and conventional resin cements to human enamel and dentin was compared .

  Materials and Methods: 80 sections of intact human third molars were randomly assigned into eight groups according to the cement type [Rely X Unicem (RXU), Rely X ARC (RXA)], bond substrate (enamel, dentin) and the duration of water storage (24 h or 1 year). Rods of cements (0.75×1 mm) were prepared on the top surface of specimens using Tygon tubes. The micro-shear bond strengths of specimens were measured by a micro-tensile tester. Data were analyzed using Wilcoxon signed ranks and Mann Whitney tests ( α =0.05).

  Results: The bond strengths of RXA and RXU cements to enamel after 24h were 18.56±4.08 MPa and 14.99±4.17 MPa, and after 1 year were 19.41±6.24 MPa and 15.51±6.17 MPa, respectively. The bond strengths of RXA and RXU cements to dentin were 13.36±4.02 MPa and 14.16±4.69 MPa after 24h , and 14.63±5.96 MPa and 14.08±6.72 MPa after 1 year, respectively. Tooth substrate had significant effect only on the shear bond strength of RXA cement after 24h (P=0.01), while no other significant differences were found in this study (P>0.05).

  Conclusion: According to the results of this study, one-step self-adhesive and multi-step conventional resin cements were similarly effective in bonding to enamel and dentin after 1 year water storage.


Saeed Nokar, Amir Azizi, Ahmad Rohanian,
Volume 27, Issue 1 (4-2014)
Abstract

  Background and Aims: Nowadays, the application of all ceramic restorations are being raised, because of their physical characteristics, such as translucency and good appearance. Numerous researchers investigated the impact of surface treatments on the bond strength of zirconia ceramic with resin cements. The aim of this study was to compare the microshear bond strength of Cercon and Zirkonzahn (two kind of zirconia) ceramics, to two types of resin cements after thermocycling.

  Materials and Methods: In this study, 24 rectangular specimens were made from each group of Cercon and Zirkonzahn ceramics. After sandblasting, these specimens were connected to 3×1 mm2 composite cylinders by two resin cements (Panavia F2 and Rely X Unicem2). After performing a thermocycling regime for 5000 cycles (5-55 ◦ C), the microshear bond strengths were measured by a universal testing machine. The mode of failures were determined by a stereomicroscope. Data were analyzed using two-way ANOVA.

  Results: Type of ceramics had no significant impact on the microshear bond strength (P=0.317). The highest bond strengths in both ceramics were obtained with Reply X Unicem (P=0.035). The predominant failure mode was adhesive between the cement and ceramic.

  Conclusion: Type of resin cement had a significant effect on their bond strengths to zirconia ceramics.


Kermanshah Hamid , Alhosseini Seyedeh Narges Ameri , Ghabraei Sholeh , Kharazifard Mohammad Javad ,
Volume 28, Issue 1 (5-2015)
Abstract

  Background and Aims: Porcelain restorations are often ground for clinical adjustment and this removes the surface glaze layer and introduces flaws that can grow in wet environments due to stress-corrosion, reduce the strength of porcelain and limit restoration lifetime. The aim of this study was to introduce some surface treatment methods to control the flaws of ceramic restorations external surface and improve their strength.

  Materials and Methods: 40 feldspathic discs were prepared and divided into 4 groups (n=10): not indented (group 1) and others indented by vickers with 29.4 N and received different treatments: no treatment (group 2), polished (group 3) and polished-silane-resin (group 4). Biaxial flexural strength of discs was tested after water storage. Data were analyzed using one-way ANOVA .

  Results: The mean flexural strength of specimens in group 1 (134.49±12.60), 2 (94.81±15.41), 3 (89.20±16.22) and 4 (80.67±12.01) were measured. Group 1 (not indented) revealed significantly higher strength (P<0.001) than that of indented groups (2, 3 and 4) . There was no significant difference between group 2 (no treatment) and 3 or 4 (treated) and between treatment methods (3 and 4) (P=0.136).

  Conclusion: The strength of porcelains is dependent on presence of cracks. With the limitations of this study, none of the treatment methods could strengthen the cracked ceramic.


Ali Eskandarizadeh, Shahram Farzin Ebrahimi, Niloofar Shadman, Saeed Rahmani,
Volume 29, Issue 1 (7-2016)
Abstract

Background and Aims: Slow polymerization rate in early stage of light curing process leads to higher monomers movement and entering in polymer network that cause higher mechanical properties.The aim of this study was to evaluate the effect of light activation methodes (immediate, 5 and 10 minutes delay) on the push-out bond strength of cemented fiber posts in different regions of root canal with two types of resin cements.

Materials and Methods: In sixty extracted human single canal, the teeth were decoronated from cement enamel junction and after root canal therapy, FRC postec plus were cemented with two resin cements, Duolink and Variolink 2, in three curing methods; immediate, 5 and 10 minutes of delay. After storing in a dark place for 24 hours, they were cut into three sections: coronal, middle and apical. The push-out bond strength test was performed using a universal testing machine. The failure modes were observed using a stereomicroscope. Data were analyzed using ANOVA and Tukey post hoc test (P<0.05).

Results: In Duolink, immediate light curing had significantly higher bond strength than that of two delayed methods (P>0.05). In immediate light curing method, regardless of root region, Duolink had higher push-out bond strength than that of Variolink 2 (P=0.02). In all subgroups, there were reductions in the bond strengths from coronal to apical. Mixed failure at the cement-fiber post interface was predominent in all groups.

Conclusion: 5 and 10 minutes delay caused reduction in the push-out bond strength for Variolink 2 but did not have significant effect for Duolink resin cement.


Mohammad Ali Keshvad, Tabassom Hooshmand,
Volume 29, Issue 2 (11-2016)
Abstract

Resin-based composite restorative materials  have a substantial share in dental treatments. Their esthetic has made them patients’ first choice as restorative materials. Marginal leakage is one of their problems which leads to recurrent caries and post-operative hypersensitivity. Our aim was to evaluate the theoretical and clinical methods that have been proposed in the dental literature. Around 50 articles from Pubmed, SCOPUS and google scholar were selected and categorized in 4 groups based on the selected keywords. All the studies discussed in this paper have emphasized that there is no way to eliminate the microleakage but it can be reduced by means of some approaches. On the other hand, due to the multifactorial nature and difference of oral environment and laboratory conditions, there isn’t any certain way to define precisely. It seems that there is an absolute need for more research in this field to make the relation of theoretical results and clinical findings possible.


Masumeh Hasani Tabatabaei, Sakineh Arami, Fatemeh Khajavi, Zohreh Moradi,
Volume 29, Issue 4 (1-2017)
Abstract

Background and Aims: Despite the reduction of incidence of dental caries in recent years, this disease is common and many efforts were conducted to decrease the prevalence of dental caries. On the other hand secondary caries lesions are the main reason for replacement of direct restorations. Therefore, the aim of the current study was to evaluate suitable methods of preparation and restorative materials to reduce caries recurrence.

Materials and Methods: In this experimental study, eighty human teeth were collected and stored in normal saline. The teeth were soft-tissue debrided and cleaned with water/pumice slurry and rubber cups in a low-speed handpiece. Speciments were randomly divided in two main groups. Cavities were prepared with diamond burs or Er:YAG laser (10 Hz, 300 mJ, 3W). Each group was divided into 4 sub-groups, and restored with a glass-ionomer cement (Fuji IX), resin modified glass-ionomer (Fuji II LC), total etch bonding + composite resin or self-etch bonding + composite resin. The specimens were submitted to pH cycling. Speciments were then sectioned, polished and Vickers microhardness measurements were performed on each specimen. Differences among the medians were analyzed using two way ANOVA test at a 95% confidence level and Tukey test.

Results: Statistical analysis showed significant difference in the type of substrate (enamel, dentin) in both main groups (P<0.0001) but no differences in the caries lesion development between the cavities restored with the same material and prepared with diamond burs or Er:YAG laser.

Conclusion: The Er:YAG laser used for cavity preparation and different types of restorative materials used did not show the ability to guarantee significantly more acid-resistance tooth structure against demineralization.


Ali Eskandarizadeh, Shahram Farzin Ebrahimi, Niloofar Shadman, Saeed Rahmani,
Volume 30, Issue 2 (8-2017)
Abstract


Background and Aims: Delay in light irradiance can improve the polymeric structure and mechanical properties of resin cement and uniform stress distribution. The aim of this study was to evaluate the effect of light activation modes (immediate, 5 and 10-minute delay) on the push-out bond strength of cemented fiber posts with two types of resin cements in different of root canal regions.
Materials and Methods: In sixty extractedsingle canal and endodontic therapied roots, FRC Postec Plus were cemented with two resin cements, Nexus3 and Panavia F2.0, in three curing methods, immediate, 5, and 10 minute delay. After 24 hours storing in a dark place, they were cut into three sections: coronal, middle and apical. The push-out bond strength test was performed using the universal testing machine. Failure modes were evaluated using stereomicroscope. Data were analyzed by ANOVA and Tukey post hoc test with P<0.05 as the level of significance.
Results: In Nexus3, the immediate light curing had significantly higher bond strength (11.18±4.32) than delay methods (P=0.001). In Panavia F2.0, the 5-minute delay had significantly the highest bond strength (13.34±4.62) (P<0.05). There was no correlation between the different light curing methods and root canal regions. In Nexus3, the coronal region had higher bond strength (11.83±3.7) than that of middle (9.12±3.1) (P=0.015), and middle than of apical (5.65±2.77) (P=0.00), and coronal than that of apical (P=0.002). In Panavia F2.0, there were not significant differences among regions (P>0.05).
Conclusion: Delay in light curing of dual-cure resin cement's had different effects on the push-out bond strength.
 

Ladan Ranjbar Omrani, Masumeh Hasani Tabatabaei, Soma Faridi, Elham Ahmad,
Volume 30, Issue 3 (10-2017)
Abstract

Background and Aims: The aim of this study was to evaluate the effects of two fluoride containing mouth rinses on the color stability of two different resin composites.
Materials and Methods: 27 specimens (2×4×5 mm) were prepared from each of the following materials: a micro filled composite (Gradia, GC) and nanohybrid (Grandio). The specimens were polished by Soflex fine and superfine disks and then incubated in artificial saliva at 37°C for 24 h. The baseline color values (L, a, b) of each specimen were measured using an Easyshade spectrophotometer according to the CIELab color scale. The specimens were immersed in 20 mL of each mouth rinse and stored in an incubator at 37°C for 12 h. After incubation, the color values of all specimens were measured again, and the color change value (ΔE) was calculated. Data were analyzed by a 2-way analysis of variance at a significance level of 0.05.
Results: None of the mouth rinses created clinical significant color changes in the samples. There was no statistically significant difference among color susceptibility between resin composites (P=0.330). The interaction between the effect of mouth rinses and type of restorative materials was not statistically significant (P>0.05).
Conclusion: Accordance to the results of this study, the fluoride containing mouth rinses does not create color change in resin composites.

Esmail Yassini, Mansoureh Mirzaei, Bahar Safaei Yazdi, Zohreh Moradi,
Volume 30, Issue 3 (10-2017)
Abstract

Background and Aims: One of the main disadvantages of light cured composite resin materials is polymerization shrinkage upon curing. This leads to the microleakage of restoration and finally failure of the restoration. The purpose of this study was to investigate the effect of two types of light curing devices with different modes on the microleakage of posterior composite filling in Cl II restorations.
Materials and Methods: In this experimental study, 30 extracted sound molar human teeth were collected. All specimens were randomly divided into 3 groups of ten: Standard LED irradiation, pulse curing LED irradiation and QTH irradiation. All samples were prepared with mesial and distal boxes and composite fillings were done with three different light curing patterns for 20 s. After thermocycling, the specimens were kept in 2% methylene Blue solution for 24 h for microleakage test. After sectioning, the samples were evaluated by a stereomicroscope. For data analysis one-way ANOVA and Kolmogorov-Smirnov were used. P<0.05 was considered statistically significant.
Results: The quantitative tests showed that there were no statistical difference between study groups (P>0.05).
Conclusion: The results showed that both light curing devices were effective and no significant difference between different modes of LED light curing device on microleakage of class II composite restorations was found.


Page 2 from 3     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb