Search published articles


Showing 25 results for Adhesive

F. Shafiee , M. Motamedi , S. Zargham ,
Volume 18, Issue 4 (1-2006)
Abstract

Background and Aim: The bonding mechanisms of self etching primers, based upon the simultaneous etching and priming of dentin, simplifies the bonding technique, but the efficiency of these systems is still controversial. This study compared the shear bond strength of three self etch adhesive systems in dry and wet conditions.

Materials and Method: In this experimental study, 77 intact bovine lower incisors with flat 600 grit sanded enamel surface were fixed in acrylic molds and divided into 7 groups, of 11 teeth. The enamel surfaces were treated according to a special procedure as follows: Group 1: Prompt L-Pop (PLP) in dry condition, Group 2: Prompt L-Pop in wet condition, Group 3: Clearfield SE Bond (CSEB) in dry condition, Group 4: Clearfield SE Bond in wet condition, Group 5: iBond (iB) in dry condition, Group 6: iBond in wet condition, Group 7: Margin Bond (Control) in dry condition. Surfaces were air dried for ten seconds, or blot dried in wet condition. Composite resin was bonded on the enamel and built up by applying a cylindric teflon split mold (4 mm height 2mm diameter). After 24 hours storage in dionized water at room temperature, all specimens were thermocycled and shear bond test was employed by a universal testing machine (Instron) with a cross-head speed of 1mm/min. The shear bond strength was recorded in MPa and data were analyzed with ANOVA and Scheffe statistical tests. P<0.05 was considered as statistically significant. The mode of failure was examined under a stereomicroscope.

Results: 1- Shear bond strength of CSEB in dry condition (21.5 ± 4.8 MPa) was significantly higher than PLP and iB groups (p<0.0001). 2- Shear bond strength of iB and PLP groups in dry condition (9.60 ± 2.2, 9.49 ± 3 MPa) were significantly lower than CSEB and control (2.99 ± 5.1 MPa) (P<0.0001). 3- There was no significant difference between PLP and iB groups in dry condition (P=1). 4- Shear bond strength of CSEB in wet condition (21.8 ± 3 MPa) was significantly higher than PLP and iB groups (P=0.0). 5- Shear bond strength of CSEB (10.8 ± 3 MPa) and PLP (10.6 ± 4 MPa) in wet condition were significantly lower than CSEB and Control groups (P=0.0). 6- There was no significant difference between PLP and iB groups in wet condition (P=0.99). 7- Shear bond strength of the three adhesives had no significant difference in dry and wet conditions (PLP: P= 0.53, CSEB: P= 0.84, iB: P= 0.53). The mode of failure in two groups of PLP and two groups of iB was predominantly in the adhesive bond and in the two groups of CSEB, mixed failure (adhesive with cohesive in composite) was predominantly observed.

Conclusion: CSEB had higher while iB and PLP showed lower bond strength to ground enamel. The three self-etch adhesives in this study did not show technique sensitivity to wet and dry enamel.


M. Farzin , F. Bahrani , Am. Rawa ,
Volume 19, Issue 2 (5-2006)
Abstract

Background and Aim: One of the most important structural factors that facilitate patient’s acceptance of full denture, is adequate and appropriate retention. The objective of this study was to evaluate the retentive ability of four denture adhesives in vitro: Safe Saze-Gum Sealing-Denstet-Corega. 

Materials and Methods: This experimental study was conducted in vitro on the basis of measurement of adhesion and cohesion forces between acrylic disk and glass, with denture adhesive applied between them. At first the retentive ability of alcohol, water and artificial saliva was measured and recorded as control. Then the retention ability of different adhesives mixed once with water and next with artificial saliva was measured and compared. The procedure was repeated 7 times for each denture adhesive with 7 similar acrylic disks. Data were analyzed using. ANOVA and paired t test with p<0.05 as the limit of significance.

Result: Comparison of four powder denture adhesives showed that the highest retentive ability was observed in Denstet and the lowest in Safe-Saze. The retentive ability of Gum-Sealing was higher than Corega.

Conclusion: Based on the results of this study, significant differences exist among the retention ability of different denture adhesives.


A. Makarem , M. Ghavam Nassiri , M. Esmaili ,
Volume 19, Issue 4 (1-2007)
Abstract

Background and Aim: Nanoleakage can cause discoloration around restoration margins, secondary caries, postoperative sensitivity and finally loss of restoration, thus adequate hybrid layer is of primary importance in prevention of nanoleakage in adhesive restorations. Because of structural differences between primary and permanent dentin, evaluation of nanoleakge in primary teeth is very important. The aim of this study was to evaluate the nanoleakage in composite restorations following application of self -etch and total-etch adhesives in primary and permanent teeth.

Materials and Methods: In this experimental study, Cl V cavities were prepared in buccal surfaces of 20 extracted primary molars and 20 extracted premolars. Each group was divided into 2 subgroups: In group (A), Gluma One Bond and in group (B), iBond adhesive materials were applied. After silver nitrate staining, specimens were mesiodistally sectioned and polished and then SEM examination was carried out to measure the nanoleakage .Data were analyzed statistically using, ANOVA and Duncan tests with p<0.05 as the limit of significance.

Results: Factors tested had no significant effect on each other. Primary teeth showed more nanoleakage than permanent teeth (P<0.05). Mean nanoleakage was significantly higher in cervical than occlusal margins (P<0.05) and also in iBond than in Gluma One Bond in primary teeth (P<0.05). In permanent teeth, the lowest nanoleakage was observed in Gluma One Bond.

Conclusion: The result of this study indicates that the use of total etch dentin adhesives (Gluma One Bond) in bonded restorations results in less nanoleakage in primary and permanent teeth.


M. Khoroushi , A. Abedini ,
Volume 20, Issue 1 (5-2007)
Abstract

Background and Aim: Patients always complain about metallic color of amalgam restorations. Covering amalgam by composite can solve this problem. Since polymerization shrinkage is a serious shortcoming in composites, application of the combined amalgam and composite restoration is one of the methods to reduce leakage in the cervical margins of posterior restorations. The aim of this invitro study was to evaluate the microleakage of amalgam/composite interface when Rely-X ARC adhesive resin cement was used in the joint.

Materials and Methods: Twenty-four sound extracted premolars were chosen. Mesial and distal class II conventional cavities were prepared and the samples were divided into 4 groups of 12. In all groups, the bases of the cavities were restored with amalgam and then the remaining part was filled by composite resin. Specimens in groups 1 and 2 were restored with composite-resin, immediately after condensing amalgam without or with application of Rely-X ARC (3M, ESPE) respectively. In groups 3 and 4, composite resin were applied 24 hours after condensation of amalgam, without or with application of Rely-X ARC respectively. After polishing and thermocycling, all specimens were prepared for dye penetration and the degree of leakage was scored and analyzed using Kruskall Wallis test with p<0.05 as the level of significance.

Results: The frequency of dye penetration in different groups was obtained. The most and the least scores were observed in groups 3 and 4 respectively. No statistically significant difference was observed in different methods.

Conclusion: None of the methods in this study could seal the amalgam/composite-resin interface.


P. Salehi, Hr. Pakshir, A. Noorafshan, N. Naseri,
Volume 22, Issue 1 (8-2009)
Abstract

Background and Aim: At the end of fixed orthodontic treatment, enamel damages are affected by amount of adhesive remnants. Thus, determining the factors involves in the amount of adhesive remnants e.g. the types of resins and the methods used for debonding is of necessity. The aim of this study was to evaluate the effect of the composite resin type and debonding pliers on enamel surface by a new method in measuring the adhesive remnant.

Materials and Methods: In this interventionally in-vitro study, 120 extracted human premolars were randomly divided into four groups of 30 each. The standard edgewise metal brackets were bonded on the teeth with two pastes self-cure composite "Concise" in the first and second groups, and with No-mix composite "Unite" in the third and fourth groups. the debonding was done by means of Lift off Debonding Instrument "LODI" (3M-Unitek), in first and third groups, and Bracket Removing Plier (Dentaurum), in the second and forth groups, respectively. After debonding, all teeth were evaluated with steriology software (stereolith version 1) for comparing the amount of adhesive remnants between the four groups. For data analysis, One-way ANOVA and independent t.test were used.

Results: The fourth group showed the lowest adhesive on the enamel surface and the most on the bracket surface with significant differences with other three groups (p<0.01).

Conclusion: The use of Dentaurum debonding plier with shear-peel force when used with the Unite adhesive (group 4), would decrease the adhesive remnants on the enamel surface.


M. Ghavam, M. Atai, M. Imani, M. Reshad,
Volume 22, Issue 2 (11-2009)
Abstract

Background and Aim: In spite of the achievements in the field of dental adhesives, we are facing challenges with dentine bonding resistance, strength and stability. According to recent studies the role of MMP inhibitors in association with bonding,s persistence and leakage reduction and restoration,s persistence is important. The aim of this study was to investigate the effect of doxycycline as a MMP inhibitor on the degree of conversion (DC) of an experimental dental adhesive.

Materials and Methods: In this experimental study, a new dental adhesive blend was prepared by mixing doxycycline monohydrate (in concentrations of 0.0, 0.25, 0.5, and 1 wt.%) with monomers. The monomers were composed of 12% Bis-GMA and 10% TMPTMA, 28% HEMA, and 50% Ethanol by weight for all groups. Comphorquinone and amines were chosen as photo initiator system. Degree of conversion of all adhesives was measured using FTIR spectroscopy. The results were analyzed using one-way ANOVA and Tukey post hoc tests.

Results: The results showed that addition of 0.25, 0.5, and 1 weight percent doxycycline did not significantly reduce the DC of the adhesives compared to 0.0% control group (p>0.05%).

Conclusion: According to the results of this study, adding doxycycline to the adhesives did not adversely affect the DC.


L. Pishevar, Sm. Mosavinasab, M. Jafari, K. Omidi,
Volume 22, Issue 3 (12-2009)
Abstract

Background and Aim: Sodium hypochlorite can remove the organic phase of the demineralized dentin and it produces direct resin bonding with hydroxyapatite crystals. Therefore, the hydrolytic degradation of collagen fibrils which might affect the bonding durability is removed. The aim of this study was to evaluate the effect of collagen fibrils removal by 10% NaOCl on dentin shear bond strength of two total etch and self etch adhesive systems.
Materials and Methods: Sixty extracted human premolar teeth were used in this study. Buccal surface of teeth were grounded until dentin was exposed. Then teeth were divided into four groups. According to dentin surface treatment, experimental groups were as follows: Group I: Single Bond (3M) according to manufacture instruction, Group II: 10% NaOCl+Single bond (3M), Group III: Clearfil SE Bond (Kuraray) according to manufacture instruction, and Group IV: Clearfil SE Bond primer. After that, the specimens were immersed in 50% acetone solution for removing extra monomer. Then the specimens were rinsed and dried. 10% NaOCl was applied and finally adhesive was used. Then composite was bonded to the treated surfaces using a 4 2 mm cylindrical plastic mold. Specimens were thermocycled for 500 cycles (5-55ºC). A shear load was employed by a universal testing machine with a cross head speed of 1mm/min. The data were analyzed for statistical significance with One-way ANOVA, Two-way ANOVA and Tukey HSD post-hoc tests.
Results: The mean shear bond strengths of groups were as follows: Single Bond=16.8±4.2, Clearfil SE Bond=23.7±4.07, Single Bond+NaOCl=10.5±4.34, Clearfil SE Bond+NaOCl=23.3±3.65 MPa. Statistical analysis revealed that using 10% NaOCl significantly decreased the shear bond strength in Single Bond group (P=0.00), but caused no significant difference in the shear bond strength in Clearfil SE Bond group (P=0.99).
Conclusion: Based on the results of this study, NaOCl treatment did not improve the bond strength in self etch adhesive and caused a significant decrease in the bond strength of total etch adhesive system.


H. Torabzadeh, A. Ghasemi, F. Asadian, A. Akbarzadeh,
Volume 22, Issue 4 (1-2010)
Abstract

Background and Aims: In this in-vitro study, the effect of multiple adhesive coating on the microshear bond strength of composite to dentin and surface microhardness of dentin after treatment with four adhesives (One Step Plus, One Step, Single Bond, Single Bond 2) were evaluated.

Materials and Methods: One hundred intact human molars were cut to obtain disks of dentin having 2 mm thickness. For the microshear bond test, sixty disks were randomly divided into four groups. In each group one type of adhesive was used. In one half of a disk two layers and in another half six layers of adhesive were applied. Cylinders with 1mm height was filled with a composite and light cured. The cross-head speed was 0.5 mm/min. Vickers microhardness was tested on forty dentin disks which divided into four groups and prepared in the same manner used for microshear bond test. Data were analyzed by Two-way ANOVA and Tukey tests.

Results: The highest and lowest bond strength were recorded as 29.49 ± 5.74 MPa (One Step Plus 6 layers), and 21.23 ± 4.83 MPa (One Step Plus 2 layers), respectively. The results indicated that One Step Plus bond strength in 6 Layers was significantly higher than 2 layers. The highest and lowest dentin hardness values were
39.08 ± 8.34VHN (Single Bond 2 layers) and 28.53 ± 5.98 VHN (One Step Plus 6 layers). None of the adhesives exhibited significant difference in hardness with regards to the layers applied (P>0.05). Presence of filler in adhesives had no significant effect on bond strength (P=0.05) whereas caused significant decrease in the dentin microhardness (P<0.05). In addition, type of solvent had significant effect on the bond strength and bond strength was significantly higher in acetone-base adhesives (P<0.05). However, dentin microhardness was significantly higher in the ethanol-base adhesives (P<0.05).

Conclusion: Multiple adhesive coating had no influence on the microshear bond strength of composite to dentin and dentin surface microhardness. It was dependent on the type of adhesive used.


M. Ghavam, S. Arami, M. Reshad, M. Imani, M. Ataei, M. Mirzaei, E. Yasini, M. Hasani Tabatabaei, A. Pahlavan, H. Kermanshah ,
Volume 22, Issue 4 (1-2010)
Abstract

Background and Aims: In spite of the advances achieved in the field of dentin adhesives, the longevity of bond to dentin is still a challenge. According to recent studies, Matrix Metaloproteinase (MMP) inhibitors can increase clinical longevity of bonding and decrease leakage. The aim of this study was to evaluate the amount and pattern of doxycycline release from an experimental dentin adhesive containing this MMP inhibitor.

Materials and Methods: In this experimental study, specimens containing 0.25 and 0.5 loading percent of doxycycline in an experimental monomer were prepared in cylindrical moulds of 12 mm diameter and 2 mm thickness. The adhesive monomer was composed of 12 wt% Bis-GMA, 10 wt% TMPTMA, 28 wt% HEMA and 50 wt% ethanol. Camphorquinone and amine were used as initiators.

Results: Addition of 0.25 and 0.5 w% doxycycline showed linear release in both groups. Increasing the loading percent of doxycycline caused more release. The release continued during the test period.

Conclusion: Doxycycline release was observed from the experimental adhesive. Further studies in this field will help in preparing adhesive systems with more clinical longevity.


Niloofar Shadman, Shahram Farzin Ebrahimi, Arezo Abrishami, Hasty Sattari,
Volume 25, Issue 3 (7-2012)
Abstract

Background and Aims: The purpose of this experimental study was to investigate the shear bond strength of three new adhesive systems to enamel and dentin of permanent human teeth using three new etch and rinse and self-etch adhesive systems.
Materials and Methods: Sixty intact caries-free third molars were selected and randomly divided into 6 groups. Flat buccal and lingual enamel and dentin surfaces were prepared and mounted in the acrylic resin perpendicular to the plan of the horizon. Adhesives used in this study were Tetric N-Bond, AdheSE and AdheSE-One F (Ivoclar/Vivadent, Schaan, Liechtenstein). The adhesives were applied on the surfaces and cured with quartz tungsten halogen curing unit (600 mW/cm2 intensity) for 20 s. After attaching composite to the surfaces and thermocycling (500 cycles, 5-55ºC), shear bond strength was measured using a universal testing machine at a crosshead speed of 0.5 mm/min. The failure modes were examined under a stereomicroscope. The data were statistically analyzed using T-test, one-way ANOVA, Tukey and Fisher's exact tests.
Results: In enamel, Tetric N-Bond (28.57±4.58 MPa) and AdheSE (21.97±7.6 MPa) had significantly higher bond strength than AdheSE-One F (7.16±2.09 MPa) (P<0.0001). Tetric N-Bond had higher bond strength than AdheSE but there was not any significant difference between them (P=0.093). In dentin, there were significantly differences among all adhesives (P<0.001). Tetric N-Bond (20.62±3.03 MPa) showed the highest and AdheSE-One F (6.54±1.13 MPa) had the lowest value. The bond strength in enamel was higher than that observed in dentin and the difference was significant in Tetric N-Bond (P=0.044) and AdheSE (P=0.000) groups. There were no significant differences in the mode of failures among groups (P>0.05).
Conclusion: Shear bond strength to dentin in Tetric N-Bond (etch and rinse system( was higher than self-etch adhesives (AdheSE and AdheSE-One F). The bond strength to enamel and dentin in two-step self-etch (AdheSE) was higher than one-step self-etch (AdheSE-One F).


Alireza Danesh Kazemi, Abdolrahim Davari, Seied Majid Mosavi Nasab, Ehsan Geravand,
Volume 25, Issue 4 (1-2013)
Abstract

Background and Aims: Re-application of microbrush may affect the micro tensile bond strength of adhesives to dentin. The aim of this study was to evaluate the effect of re-application of microbrushes on the micro tensile bond strength of an adhesive to dentin.

Materials and Methods: Thirty freshly extracted molars teeth were collected and enamel of occlusal surface were removed to expose superficial dentin. Then superficial dentin was etched, washed and partially air dried. According to the times of application of microbrush, teeth were divided into two test groups. In group 1, new microbrushs were used, but in group 2, the ones that were already used for twice were included. Ambar dentin bonding agent (FGM/Brazil) was applied to the etched dentin with microbrushes according to the manufacturer's instructions. Then the crown of teeth was built up with LLiss (FGM/Brazil) composite resin. The teeth were sectioned in buccolingual direction to obtain 1mm slabs. Then 50 hourglass- shape samples were made from 30 teeth (25 Specimens per group). The microtensile bond strength of the specimens was tested using MTD500 (SD Mechatronik, Germany). The data were statistically analyzed by T-test.

Results: The mean values for the microtensile bond strength were 30.49±7.18 and 23.61±9.06 MPa±SD for the first and second groups, respectively. There was significant difference between the groups (P=0.005).

Conclusion: Microbrushes should not be used for more than one cavity preparation.


Alireza Daneshkazemi, Abdolrahim Davari, Majid Mousavinasab, Alireza Zahedifar,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Today, use of adhesive systems is the most common materials in restorative dental procedures. The aim of this study was to evaluate the effect of different air-drying periods on the microtensile bond strength of composite to dentin using adhesive.

Materials and Methods: 15 sound molar teeth were selected. The an occlusal surfaces of teeth were removed with silicon carbide disks (3M/USA) to reach flat surface of dentin. Then according to the air drying of solvent, the teeth were divided to five groups. After 5 sec etching and rinsing for 15 sec , the teeth were air dried for 3 sec . Then Singlebond (3M) was used with different air-drying times (0s, 2s, 5s, 10s, 30s) and cured. Then after insertion and curing of Saremco (microhybrid low shrinkage/Switzerland) composite, the teeth were thermocycled for 500 cycles. Then hour glass slabs with 1 mm2 interface was created. Specimens were then subjected to µTBS force until fracture. Data were analyzed using ANOVA and Bonferroni tests.

Results: Statistical tests showed that there were significant differences between bond strength of groups (P=0.002). The mean of µTBS for the 2 Sec and 30 Sec evaporating time was the most and the least vawes, respectively.

Conclusion: An optimum air-drying time for solvent evaporation was the lowest time recommended by the manufacturer. Over and under evaporation time decreased µTBS significantly.


Davari Abdolrahim , Kazemi Alireza Danesh , Mousavinasab Majid , Mohammadi Najmeh Pour ,
Volume 26, Issue 3 (8-2013)
Abstract

  Background and Aims: Different adhesives with different solvents may have different solvent evaporation rates. The purpose of this study was to evaluate the solvent evaporation in the self etch and total etch adhesive in different air drying times.

  Materials and Methods: Five adhesives were used in this study: Excite, Prime & Bond NT, UNO, Single Bond, SE Bond Primer. Twelve drops of each adhesive were used for each period of air drying (5, 15, 30 sec). The percentage of mass loss was measured during each test. Data were analized using two-way ANOVA and Tukey.

  Results: Acetone base adhesives showed more loss of mass than other adhesives (P<0.01). P&B NT showed more loss of mass than other adhesives in all air drying times (P<0.01). Adhesives showed different evaporation rates in different air times (P<0.01).

  Conclusion: Adhesives with acetone/water or alcohol/water solvent shows more stable behavior in comparison with adhesives containing pure aqueous solvents.


Mehran Bahrami, Maryam Memarian, Farinaz Khodadad Kashi,
Volume 28, Issue 3 (10-2015)
Abstract

Background and Aims: Residual ridge resorption is an unpredictable, unavoidable and time-dependent process which occurs in denture-wearing patients especially those who use mandibular dentures. This process causes more problems in mandible because of its less support, tongue forces and more resorption. Inserting implants in many of these patients requires bone grafts. Overdentures are also more expensive. Denture adhesives are the last option to improve retention and masticatory function in denture-wearers with severe resorption of alveolar ridge. Nowadays only a few denture adhesives are used in Iran and there is not much information about their standard features including, pH, bond strength and washability. The objective of this study was to examine and compare the mentioned characteristics of four denture adhesives (Professional, Corega, Fittydent and Fixodent) and to introduce the most suitable denture adhesive for clinical use.

Materials and Methods: All the methodologies of ISO 10873:2010 were applied. To measure the pH value, 1±0.1g of each denture adhesive was diluted with 5g of propylene glycol and mixed with water. Using pH meter, pH of each group was measured separately for 4 times (n=4) and results were recorded. For the washability test, 4 dentures were fabricated (n=4) and each group of denture adhesives was placed on a denture according to manufacture instructions. For simulating mouth environment specimens were placed in water at 37±2 ̊C bath for 1 hour and then washed with a plastic brush. Specimens were examined for any residual adhesive and the results were recorded. For bond strength test, a sample holder was gently filled with denture adhesives and was attached to the holding arm of bond strength testing device (Santam, STM 20, Iran). Specimens were placed in 300ml water bath at 37±2 ̊C for 10 minutes, and then shaken to be dried and placed in the bond strength testing device. 10N force with 5mm/min rate was applied to the specimen. The force was maintained for 30s and then device arm was pulled back and the highest number was recorded with computer software (Santam Machine Controller v4.19, Iran). The test performed 8 times (n=8) for each adhesive and 8 results were recorded. Data were analyzed using ANOVA test for comparing the bond strength with a significant level fixed
at 0.05.

Results: Professional and Corega adhesives had more neutral pH than that of Fittydent and Fixodent which were more acidic. Washability test showed no remaining mass of any adhesive and there was not any statistically significant difference between groups (P>0.05). Fittydent and Corega adhesives showed higher bond strength than that of Professional and Fixodent and this difference was statistically significant (P<0.05).

Conclusion: Professional and Corega adhesives had less acidity. Thus they cause less harmful effects on the oral mucosa than that of Fittydent and Fixodent and should be indicated in patients with little-tolerant oral mucousa such as diabetous, iron-deficiency anemia and hypertention. All the groups had acceptable washability. Fittydent and Corega had higher bond strength than that of Professional and Fixodent. Therefore in complete-denture-wearers who require more retention as a result of severe ridge resorption, macrotruma, and maladaptiivity, Fittydent and Corega seems to be more acceptable.


Mohammad Javad Moghadas, Ehsan Rohani, Sara Majidinia, Najmeh Ojrati, Negin Vatanparast,
Volume 31, Issue 4 (1-2019)
Abstract

Background and Aims: The aim of the present study was to evaluate the effect of applying hydrophobic resin after use of different generation of the bonding systems on nanoleakage.
Materials and Methods: 20 third molar teeth were selected. The teeth were randomly divided into 4 groups of 5, each was treated using the fourth, fifth, sixth, and seven generation of dentin bonding. Then, the crown of teeth was sectioned from the CEJ region and each specimen was divided into two halves with mesiodistal cut, one half for the application of dentin bonding without the addition of a hydrophobic resin, and the other for the same dentin bonding by the addition of a hydrophobic resin. Afterwards, the specimens were restotred by composites. After placement of specimens in silver nitrate, the amount of nanoleakage was evaluated by SEM. Data were analyzed using a repeated measurement statistical analysis (α=0.05).
Results: The use of hydrophobic resins decreased nanoleakage and range of variations in all groups (P<0.05). This reduction was greater for total-etch dentin bonding. Higher degree of nanoleakage occurred in total-etch dentin bonding in most evaluated areas. In general, Clearfil S³ bond showed the least percent of the nanoleakage.
Conclusion: All dentin bonding systems showed some degree of reduction in nanoleakage after hydrophobic layer application and the reduction was greater in Total-etch adhesives systems.

Pooya Jannati, Faranak Vakili, Saeid Nokar, Somayeh Zeighami,
Volume 36, Issue 0 (5-2023)
Abstract

Background and Aims: Endocrown is a type of monoblock restoration using the pulp chamber and remaining coronal tooth structure for retention. Advancements in adhesive techniques have breathed fresh spirit into endocrown. Nowadays, there are two approaches for endocrown: conventional approach and  biomimetic approach. This study aimed to review data on the steps and clinical and philosophical points of using these approaches to help dentists’ selection and performance.
Materials and Methods: The review was conducted by reviewing the articles available in PubMed, Scopus, and Google Scholar databases from 1995 to 2022. The keywords used were; Crown, Endodontically-treated teeth, Light-curing of dental adhesive, Onlay, and Post-Core.  
Results: After removing duplicates, titles/abstracts were reviewed. Animal studies, studies without available full text or non-English language studies were excluded from the study. Then, the full texts of the remaining 59 articles were evaluated and 49 articles were eligible for the present study. The articles included clinical trials, in vitro, systematic reviews, and case reports.
Conclusion: Endocrown is a successful alternative to crown, especially in molar teeth. Regardless of the conventional or biomimetic approach, this treatment has a more favorable fracture pattern while preserving the remaining tooth tissue as much as possible.

Maryam Saadat, Marzieh Moradian, Zahra Akbari, Parisa Ghodati,
Volume 37, Issue 0 (3-2024)
Abstract

Background and Aims: The bond strength of direct composite restoration to the caries affected dentin is a challenging issue. Preparation of dentin with an antibacterial agent is a method for creating durable bonded restorations. The aim of this study was to investigate the effect of curcumin photosensitizer on the bond strength of a universal adhesive to the caries-affected dentin (CAD).
Materials and Methods: In this experimental in vitro study, forty-four decayed human molar teeth were selected. After removing the surface enamel and dentin by a water-cooled saw, the decayed mid-coronal dentin was stained with a caries detection solution. The green and soft infected dentin was removed and CAD and hard and healthy surrounding dentin were left. Then, the remaining dentin surfaces were treated by 600 grit silicon carbide papers and polished. The specimens were divided into two groups (n=22): dentin pretreatment group by curcumin and control with no dentin pretreatment group by curcumin.  Each group was divided into two subgroups based on the method of application of All-Bond Universal adhesive (Bisco, USA) (etch and rinseand self-etching methods). After placing the Aelite All Purpose Body (Bisco, USA) composite, all  specimens  were placed in a universal testing machine for microshear bond strength (µSBS) test. The failure mode of the isolated surfaces was evaluated under a stereomicroscope. Two-way ANOVA analysis was used for statistical analysis.
Results: Based on the obtained results, intervention with the adhesive application method and surface pretreatment with curcumin had no significant effect on the bond strength. Also, there was no significant difference in the bond strength of the curcumin group in both etch and rinse and self-etching methods (SE=56.3±27.11 MPa; ER=52.4±84.11 MPa) (P=0.847). In the curcumin-free group, there was no significant difference between the two different adhesive application methods (P=0.187).
Conclusion: The results obtained in the present study showed that the pretreatment of dentin affected by caries with light-sensitive curcumin and also use of a universal adhesive by either self-etching or self-etchinf methodshad no influence on the microshear bond strength of the composite restoration.

Elahe Soltanmohamadi Borujeni, Ali Bavi, Mohammad Aghaali, Ali Saleh, Aida Mehdipour,
Volume 37, Issue 0 (3-2024)
Abstract

Background and Aims: Strong bond between the ceramic brackets and ceramic veneers has an important role in cosmetic treatment. The purpose of this study was to investigate the effect of aging on the shear bond strength (SBS) of ceramic brackets bonded to zirconia after surface preparation by Neodymium-doped Yttrium Aluminum Garnet (Nd: YAG) laser or sandblasting with alumina.
Materials and Methods: This experimental study was conducted on 24 zirconia blocks and these blocks were randomly divided into two groups for surface preparation and each was sub-divided into three time intervals. Surface preparation was done by sandblasting with alumina: in SG1 (Immediately after sandblasting), SG2 (2 weeks after sandblasting), and SG3 (3 months after sandblasting) groups. For the Nd: YAG laser (1/5W, 20Hz, 10s) with non-contact mode: in LG4 (Immediately after laser), LG5 (2 weeks after laser), and LG6 (3 months after laser) groups. The ceramic brackets were bonded to the zirconia blocks. The SBS and adhesive remnant index (ARI) were evaluated and compared among test groups. Dara were analyzed using Mann Whitney test.
Results: There was no significant difference between the SBS of SG1 and LG4 (P=0.430), SG2 and LG5 (P=0.382) and SG3 and LG6 (P=0.326) groups. LG4 group showed the highest shear bond strength. After aging (2 weeks and 3 months), the laser groups showed higher SBS. There was no significant difference in the ARI between SG1 and LG4 (P=0.220), SG2 and LG5 (P=0.154), SG3 and LG6 (P=0.527) groups.
Conclusion: No significant difference was observed between the Nd: YAG laser and sandblasted groups in terms of SBS and ARI over time. Therefore, Nd: YAG laser could be used as a surface treamnet method in Zirconia crowns for bonding to ceramic brackets.
 
Mostafa Sadeghi, Niloufar Jafari, Mohammadhossein Kafi, Ali Rostami,
Volume 38, Issue 0 (4-2025)
Abstract

Background and Aims: The development and regular use of adhesive systems has started to revolutionize many aspects of restorative and preventive dentistry. The success of adhesive restorations highly depends on correct application of them. Therefore, the present study was conducted with the aim of determining the knowledge of dentists in Rafsanjan city (Iran) in choosing correct dental adhesive systems in 2023.
Materials and Methods: In this cross-sectional descriptive study, all dentists working in Rafsanjan city were included. The data was collected by a valid and reliable electronic questionnaire, which included two parts of demographic information (gender, age, place of work and year of graduation) and the 12 multiple-choice questions aimed to assess respondents' knowledge regarding the selection of dental adhesive materials in combination with self-cure or dual-cure composites, anterior and posterior composite restorations, fiber posts, fissure sealants, primary teeth, anterior composite veneers, ceramic laminates, and non-carious cervical lesions. The scoring of this questionnaire was as follows: 0 to 3 correct answers = Low level of knowledge; 4 to 6 correct answers = Moderate level of knowledge; 7 to 9 correct answers = Good level of knowledge; 10 to 12 correct answers = Very good level of knowledge.  The four answer choices included "etch-and-rinse (three-step)", "etch-and-rinse (two-step)", "self-etch (two-step)", and "self-etch (all-in-one bottle)". Then data were analyzed by parametric tests (ANOVA, t-test, and Pearson). The significant level was considered as P<0.05.
Results: Out of 91 dentists in Rafsanjan, 79 (86.8%) participated in the study, of which 35 (46.3%) were men. The average work experience was 3.49±3.96 years for men and 2.98±3.73 years for women. The average knowledge score was 4.38±2.16 out of 12 (4.29±2.23 in men and 4.45±2.12 in women). The results showed that there was no significant relationship between the knowledge score and the gender, age, work experience, and workplace (P>0.05).
Conclusion: According to the results which indicated the insufficient knowledge of dentists in  choosing correct dental adhesive systems, it is suggested to pay more attention on teaching in this field at the dental schools. For graduate dentists, new and practical information about the choice of adhesive systems should be provided by continuous education programs.

Sayeh Hamedanchi, Hafez Vahedpour, Solmaz Charmi,
Volume 39, Issue 0 (3-2026)
Abstract

Background and Aims: Repairing existing composite restorations, rather than replacing them entirely, is regarded as a conservative and tissue-preserving approach in restorative dentistry. However, achieving a durable bond between the aged and newly applied composite resin remains a significant clinical challenge. This study aimed to compare the shear bond strength of repaired composite restorations using three different adhesive systems.
Materials and Methods: In this in vitro study, which conducted at the Faculty of Dentistry, Urmia University of Medical Sciences, 60 disk-shaped composite specimens were fabricated with standard dimensions. After undergoing artificial aging (storage in distilled water for 6 months), their surfaces were roughened mechanically using a diamond bur. The specimens were randomly divided into three groups (n=20) and repaired using fifth-generation (Adper Single Bond), seventh-generation (OptiBond All-In-One), and universal (Single Bond Universal) adhesives, followed by the application of new composite. All  specimens were subjected to thermocycling, and the shear bond strength was measured using a universal testing machine. Fracture patterns of the samples were also examined using a stereomicroscope to determine the modes of failure. Data were analyzed using one-way ANOVA and Chi-square tests in SPSS at a significance level of 0.05.
Results: The mean shear bond strengths were 15.22 ± 4.47 MPa for Adper Single Bond, 14.05 ± 4.66 MPa for OptiBond All-In-One, and 13.44 ± 4.68 MPa for Single Bond Universal. No statistically significant differences were found among the groups (P=0.468). Fracture pattern distribution was also not significantly different (P=0.453), with predominantly cohesive or mixed failures observed across all groups. No adhesive failures were observed.
Conclusion: Under standardized surface preparation, none of the tested adhesive systems demonstrated a statistically significant advantage in the shear bond strength between the aged and new composite. Therefore, the choice of adhesive in composite repair procedures can be guided by practical considerations such as product availability, ease of application, and dentist preference.


Page 1 from 2    
First
Previous
1
 

© 2026 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb