Search published articles


Showing 26 results for Dental Implant

Abbas Rahimi Foroushani, Nooshin Akbari Sharak, Mohamad Javad Kharazi Fard,
Volume 30, Issue 2 (8-2017)
Abstract


Background and Aims: In recent years, dental implants have received special attention in dentistry. Due to the remarkable success of predictable dental implants, there is growing interests in the scientific community from descriptions of implant success toward identify factors associated with implant failure. The purpose of this study was to identify the risk factors associated with implant failure in an objective and statistically valid manner.
Materials and Methods: To address the research purposes, we used a cohort study in which a total of 2368 implants were placed on 1011 patient in the Clinic of Tehran University of Medical Sciences. The predictor variables included demographic variables, the health status and variables are related to implants. The outcome variable of interest was implant failure. The overall implant survival was estimated using the Kaplan-Meier analysis. First, risk factors were identified using Chi-square test and Fisher's exact test and then the Cox proportional hazard regression models were used for more analysis.
Results: The overall 39 month implant survival using the Kaplan-Meier function was 0.99±0.002. The implant location (jaws) (P=0.049) and type of teeth (P=0.011) were found to have significant relation with failure times in Cox proportional hazard model.
Conclusion: According to result of this study, both implant location and type of teeth had effection the failure times so that, the survival in mandible was higher than maxilla. The failure rate was higher in anterior teeth than that of others (molar, premolar, canine and primary).
 

Somayeh Zeighami, Marzieh Alikhasi, Maryam Memarian, Moeen Hosseini Shirazi,
Volume 30, Issue 4 (1-2018)
Abstract

Background and Aims: For the clinical success of implant-retained prostheses, fitness of matching components and stability of the applied torque to the implant-abutment assembly under dynamic occlusal loading is essential. The aim of this study was to evaluate the torque loss in Co-Cr castable abutments after cyclic loading.
Materials and Methods: 10 castable abutments were cast in Co-Cr alloy with similar size and height. Each specimen was mounted vertically on a separated implant using a 30 Ncm tightening torque. The detorque values of the abutments were evaluated after 10 min. The same tightening torque was applied to the abutments on their corresponding implants and cyclic loading was applied for 500,000 cycles to the implant-abutment assembly. The torque values after cyclic loading were recorded for each specimen. T-test analysis was conducted on scores from the groups.
Resultes: The results of this study showed that the percentage of torque loss in castable abutments was significantly increased after cyclic loading (P<0.001).
Conclusion: Misfit between the castable implant components can cause torque loss before and after cyclic loading. However, it is more appropriate to relate the results of this study to the screw loosening of the above mentioned abutments than judging their clinical performance.

Mohsen Sharif Zadeh Ardakani, Ali Mohammad Salari, Mahmod Nasre-Esfahani,
Volume 33, Issue 3 (10-2020)
Abstract

Background and Aims: With increasing age and inability to maintain good oral hygiene, the chances of tooth loss increase and the need for dental implants will increase in the future. It also increases the risk of developing peripheral implants, especially at older ages in the failure of implant treatments. Recently, the high prevalence of cardiovascular disease and peri-implantitis in the elderly has been reported. The aim of this study was to investigate the effect of cardiovascular disease on the peri-implantitis in people with failed dental implants.
Materials and Methods: In this retrospective study, the files of patients referred to Shahid Montazeri Dental Clinic from 2009 to 2018 whose their failed implants were extracted, were collected. There were a total of 793 people with failed dental implants. The variables of this study were demographic information including age and sex, health status in terms of cardiovascular disease and peri-implantitis, which were identified and then statistically analyzed by examining the files of patients with these two variables. Data were statistically analyzed by SPSS25 statistical software and Chi-square was used to determine the effective variables.
Results: A total of 793 patients had failed dental implants, including 368 women (46.4%) and 425 men (53.6%) with an average age of 50.79 years. 42 patients (5.3%) had heart disease and 44 (5.5%) had peri-implantitis. According to the Chi-squared test, the significance level was less than 0.05 (P=0.011).
Conclusion: The results of this study showed that the cardiovascular disease and peri-implantitis were significantly related.

Dr Gelareh Eblaghian, Dr Alireza Reyhani Mohamadi, Miss Maryam Kalantari Nezhad,
Volume 34, Issue 0 (5-2021)
Abstract

Background and Aims: Nowadays, the best choice for replacing missing teeth are dental implants, however, failure is not unexpected. One of the factors that plays an important role in the implant failure is bacterial microleakage which could cause biological complication. The aim of this study was to compare the bacterial microleakage between the two types of implants.
Materials and Methods: In the present interventional study, SPI and Dentis implants were placed bilaterally in the premolar-molar area of the patients' mandible. One day and 14 days after the delivery of the crown, by removing the crown and removing the abutment, sampling was performed using a sterile paper cone from four areas. One day after sample culturing, the number of colonies was counted. All data were entered into SPSS 23 and were analyzed using independent samples t-test and paired t-test with a significance level of 0.05.
Results: The amount of bacteria in implant sulcus was significantly different between the two types of implants (P=0.003). After 14 days, the amount of bacteria in SPI implant sulcus significantly decreased more than Dentis implant sulcus (P=0.001). After 14 days, the amount of bacteria also decreased in all other areas which there were no significant difference between the two types of implants (P>0.05).
Hosnie Yusefi Fakhr, Yadollah Soleimani Shayesteh, Afshin Khorsand, Mehrdad Panjnoush, Mohammad Javad Kharazi Fard, Mohadeseh Heidari,
Volume 35, Issue 0 (5-2022)
Abstract

Background and Aims: According to the importance of primary stability on dental implant success and osseointegration, we intend to check and compare the stability and crestal bone loss rate between osteotomy technique and conventional implant insertion techniques.
Materials and Methods: In this study, 26 implants in anterior segment of maxilla in 13 patients were evaluated. The implants were TBR system (Toulouse, France) with 3.5 diameter and 10.5-12 mm length. The implant stability level was recorded immediately after surgery and 3 months later with Ostell mentor. The periapical radiography was taken immediately after surgery, 3 and 6 months to assess crestal bone resorption. Paired t-test and Wilcoxon signed Rank test used for data analysis.
Results: There were no statistically differences between the two treatments techniques in terms of stability (P>0.05). The mean crestal resorption was higher for the osteotomy technique 3 months after implant insertion (P<0.001) but there were no significant differences after 6 months (P=0.678).
Conclusion: Within the limitations of the current study, it can be concluded that the osteotomy it can be considered as a treatment technique in insufficient bone width.

Mohammad Hossein Zare Mehrjardi, Sina Hooshmand, Mahnaz Hatami,
Volume 38, Issue 0 (4-2025)
Abstract

Background and Aims: Despite significant advancements in rehabilitation of edentulism with implants, complications such as implant failure before and after prosthetic loading remain concerns. This study aimed to evaluate the frequency of dental implant failure before and after prosthetic loading in some of Yazd dental clinics between 2018 and 2023.
Materials and Methods: In this descriptive cross-sectional study, 1060 patients’ files from three public dental clinics were reviewed. These patients were treated by dental implants between April 2018 and June 2023. The collected data included patients’ age and gender, implant diameter, brand, and placement site, type of prosthesis, and fixture failure after surgical and prosthetic phases. Data were statistically analyzed by independent t-tests and chi-square tests.
Results: The mean age of patients was 55.25 ± 12.37 years and 56.3% were female. The frequency of overall implant failure was 3.4%. The implant failure rate after prosthetic loading was 2.8% in females and 2.3% in males (P=0.47). This rate was 2% and 1.9% for maxillary and mandibular implants, respectively (P=0.5). This amount was 2.4% in molar areas,1.7% and 1.8% in premolar and anterior regions, respectively  (P=0.8). Implant failure rate was 1.3% in overdentures, 5.9% in cement-retained, and 3.2% in screw-retained prosthesis (P<0.001). This amount for implants with a diameter less than 3.75 mm was 2.6% and for those with a diameter more than 4.5 mm was 3.7% (P<0.001). Implants with a diameter less than 3.75 mm had a 2.6% failure rate, whereas those with a diameter greater than 4.5 mm had a 3.7% failure rate (P<0.001). The implants failure rate was 1.6% for Dio brand and 2.5% for Dentis (P=0.5).
Conclusion: The overall implant failure rate in this study was 3.4%, of which 1.5% occurred before and 1.9% occurred after prosthetic loading. The frequency of implant failure after loading was significantly associated with the implant diameter and prosthesis type. This was not related to the patient's gender, implant site, or the implant brand.


Page 2 from 2     

© 2026 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb