Search published articles


Showing 1049 results for Type of Study: Research

Marzieh Alikhasi, Roshanak Baghaie, Nasim Khosronejad, Pooya Aslani,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: In response to esthetic demand of patients, ceramic abutments have been developed. Despite esthetic of zirconia abutments, machining accuracy of these abutments has always been a question. Any misfit in the abutment-implant interface connection can lead to detorque and screw loosening. The aim of this study was to compare torque loss value of manually aided design/manually aided manufacture (MAD/MAM) zirconia abutments with prefabricated titanium abutments.

Materials and Methods: Seven titanium abutments (Branemark RP, Easy abutment) and seven copy milled abutments which were duplicated from the prefabricated Zirkonzhan (ZirkonZahn, Sand in Taufers, Italy) were prepared. After sintering process of zirconia abutment, all abutments were fastened with a torque screw under 35 Ncm. Detorque measurements were performed per group pushing the reverse button of the Torque controller soon after screw tightening with values registered. The mean torque loss were calculated and compared using Student's t test.

Results: The mean of torque loss was 12.71 Ncm with standard deviation of 1.70 for prefabricated titanium abutments and 15.50 Ncm with standard deviation of 4.67 for MAD-MAM abutments. The difference between the two groups was not statistically significant (P=0.23).

Conclusion: Within the limitation of this study, MAD-MAM ceramic abutments could maintain the applied torque comparing to the prefabricated abutments.


Azita Kaviani, Asadoallah Ahmadzadeh, Maryam Zarei,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: Discoloration of resin composites is considered to be the major factor in esthetic restoration failures. The aim of this study was to evaluate the color stability of resin composites after rebonding with two different adhesive materials.

Materials and Methods: Forty five composite disc samples were divided into three groups (n=15). The surface of specimens was finished by polishing disc and rubber. In group 1, any additional phase was not performed. In group 2, composite discs were etched by %37 orthophosphoric acid, then Margin- bond was used for rebonding. In group 3, the etching procedure was in the same manner used for group 2, but Permaseal was used after etching. After the first phase of spectrophotometric measurement, the specimens were dipped in coffee mix for 3 weeks for aging the specimens. Then the second phase of spectrophotometric evaluation was performed. Collected data was analyzed using one-way ANOVA test followed by Tukey test. P<0.05 was considered as the level of significance.

Results: The mean total color difference (∆E) observed in groups 1 to 3 were 1.4±0.34, 5.24±1.51, and 7.44±1.34, respectively. Statistical significant differences were shown between the groups (P<0.001).

Conclusion: Rebonding with adhesive materials used in this study did not increase the color stability of composite restorations.


Masumeh Hasani Tabatabaei, Sakine Arami, Ayob Pahlavan, Esmaeil Yasini, Mansoure Mirzae, Hamid Kermanshah, Farnaz Farahat,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: To evaluate the effect of polishing on surface roughness of silorane-based composite using profilometery and Scanning Election Microscopy (SEM) and compare it with that of a methylmethacrylate-based composite and a glass ionomer.

Materials and Methods: In this study, 3 groups (n=28) were tested: specimens of two composites (Filtek P90 and Filtek P60) and a glass ionomer (Fuji IX) which were prepared in polyethylene molds (4 mm diameter×10 mm height). Half of the specimens in each group were finished with 180-grit silicon carbide paper and the remaining were finished with 180-grit, and subsequently polished with 250, 400, 800, 1000, 2000, and 2500-grit silicon carbide papers. The surface roughness was evaluated using a contact profilometer and then mean (Ra) and maximum (Rmax) of surface roughness were recorded. Then, the surface of 4 specimens of each subgroup was observed under SEM. Statistical analysis was performed with T-test, ANOVA and Dunnett T3 tests.

Results: In all materials, Ra was different between polishing with 180 and 2500-grit silicon carbide papers. In 180-grit group, only Ra of Filtek P60 and Fuji IX showed significant difference (P=0.01). In 2500-grit group, there was no significant difference between the Ra of Filtek P60 and Filtek P90 (P=0.56).

Conclusion: Polishing is recommended for the glass ionomer and posterior composite restorations.


Ayob Pahlavan, Masumeh Hasani Tabatabaei, Sakineh Arami, Mohammad Ataie, Sara Valizadeh,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: Polymerization shrinkage in Methacrylate-based composite is one of the most important factors in composite restorations failure. Silorane-based composite is introduced to compensate this drawback and claimed to have low shrinkage. The aim of this study was to evaluate the polymerization shrinkage of these two composites.

Materials and Methods: In this experimental study, 5 disk shape samples for each resin composites were placed in the centre of metallic ring bonded to microscopic glass slab. Top surface of ring was covered by a glass cover slip. Glass slab and sample were placed on a special LVDT holder in order to light cure from bottom surface and to measure the polymerization shrinkage. In this study, Deflecting Disk method and LVDT (linear variable differential transducer) was used for dimensional change measurement of resin composites. In this study, two LED curing units were used for composite polymerization.

Results: The mean of polymerization shrinkage in Z250 cured with LED and High Power LED was 11.15±0.08µm and 11.51±0.17µm, respectively (P=0.094), and in P90 cured with LED and High Power LED was 1.08±0.06µm and 1.16±0.12µm, respectively (P=0.019).

Conclusion: Silorane-based composite (P90) showed significantly less polymerization shrinkage than that of methacrylate-based composite (Z250). For the two types of composite, there was no significant difference between the two curing units in polymerization shrinkage.


Ayob Pahlevan, Tabassom Hooshmand, Mansoreh Mirzaie, Hoda Safaie,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: The purpose of this in vitro study was to assess the effect of two different surface treatments on the contrast ratio of IPS e.max press ceramic submitted to accelerated aging.

Materials and Methods: Ten ceramic (IPS e.max Press) disks (10-mm diameter and 1.5-mm thick) were fabricated according to the manufacturer's recommendations. The samples were randomly divided into 2 groups (n=5): polishing and glazing. Contrast ratio ware obtained with a spectrophotometer before and after accelerated aging. The contrast ratio (CR=Yb/Yw), was defined as the ratio of illuminance (Y) of the test material when it is placed on the black background (Yb) to the illuminance of the same material when it is placed over a white background (Yw), was determined. The data were statistically analyzed by two-way analysis of variance (P<0.05).

Results: All specimens of IPS e.max press ceramic showed significant increase in CR after 300-hour accelerated aging time (P=0.005). Polished samples showed significantly higher opacity compared with that of the glazed ones (P=0.018).

Conclusion: Within the limitations of this study, it may be concluded that the glazed specimens showed higher stability in their translucency than the polished specimens.


Hamid Kermanshah, Esmaiel Yasini, Razieh Hoseinifar,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: Marginal seal in class V cavity and determination of the best restorative material in reducing microleakage is of great concern in operative dentistry. The aim of this study was to evaluate the effect of load cycling on the microleakage of low shrinkage composites compared with methacrylate-based composites with low shirinkage rate in class V cavity preparation. Marginal integrity of these materials was assessed using scanning electron microscope (SEM).

Materials and Methods: In this in vitro study, class V cavity preparations were made on the buccal and lingual surfaces of 48 human premolars and molars (96 cavities). The specimens were divided into four groups each containing 12 teeth (24 cavities): group 1 (Kalore-GC+ G-Bond) , group 2 (Futurabond NR+Grandio), group 3 (All Bond SE+ Aelite LS Posterior), group 4 (LS System Adhesive Primer & Bond+Filtek P90). All the specimens were thermocycled for 2000 cycles (5-50oC). In each group, half of the specimens (n=12) were subjected to 200,000 cycles of loading at 80 N. Epoxy resin replicas of 32 specimens (4 restorations in each subgroup) were evaluated using SEM and the interfacial gaps were measured. Finally, the teeth were immersed in 0.5% basic fuchsin dye for 24 hours at 370C, then sectioned and observed under stereomicroscope. The data were analyzed using Kruskal-Wallis and Mann-Whitney U tests and the comparison between occlusal and gingival microleakage was made with Wilcoxon test.

Results: Within unloaded or loaded specimens, there were no significant differences in microleakage among four groups on the occlusal margins (P>0.05). But there were statistically significant differences in microleakage between silorane and Aelite on the gingival margins (P<0.05). No statistically significant differences were found between the microleakage of the loaded and unloaded groups on both occlusal and gingival margins for all materials (P>0.05).

Conclusion: Silorane did not perform better than the conventional low shrinkage methacrylate-based composite in terms of sealing ability (except Aelite). Cyclic loading did not increase the extent of leakage in any groups.


Sakineh Nikzad, Abbas Azari, Mani Arashrad, Ghazal Arashrad,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: The marginal integrity of fixed restorations always is a major matter of concern for dental clinicians. Any cause of distortion, including veneering processes, in the marginal integrity is supposed to be detrimental for long-term success of fixed dental prostheses. The aim of this in vitro study was to compare the marginal adaptation of two different full ceramic restoration systems (Zirkouzahu&Cercon) and possible changes in marginal integrity following the multiple veneering process.

Materials and Methods: Twelve all-ceramic crowns in the form of coping were fabricated on a pre-made standard metal die with finish line of shoulder preparation from two commercial systems: Cercon® and Zirkonzahn®. The specimens were not cemented. The Crown/Die discrepancy were measured by means of a precise stereo microscope (accuracy±0.1 μm), at various points (n=12) selected along circumferential margin of the restorations. Same procedure was accomplished after applying the veneering porcelain. The mean gap dimensions were calculated and data were analyzed by multivariate (b) test.

Results: Mean marginal gap dimensions before and after veneering porcelain firing cycles, for Cercon® were (59.67±13.46 µm) and (63.75±14.16 µm) and for Zirkonzahn® were (65.81±24.37 µm) and (64.74±21.94 µm), respectively. Hotelling trace Multivariate(b) test method showed that the rate of mismatching marginal integrity in two groups (Cercon® and Zirkonzahn®) had no significant difference before and after porcelain firing (P>0.05).

Conclusion: Within the limitation of this study, the marginal integrity of both systems were seems to be within the clinically acceptable standard dimension, i.e. 120μm.The marginal gap of both all-ceramic systems were not affected by veneering porcelain firing cycles.


Fateme Nematollahi, Nasim Azizi, Sima Shahabi, Loghman Ghahremani, Zohre Asgari, Hossein Bagheri ,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Failure of bonding between artificial teeth and denture base material is a considerable problem for patients who wear dentures. According to the different impact of artificial teeth and different information about resistance force of mastication and also with deficiency in researchs, this study was designed to compare the bond strength of composite and acrylic artificial teeth to auto-polymerized denture base resins with and without cyclic loading.

Materials and Methods: In this experimental and in vitro study, an acrylic resin auto-polymerized (Rapid Repair, Dentsply) and four artificial teeth (Acrylic Marjan new, Composite Glamour teeth and Ivoclar acrylic and composite teeth) were used. Therefore, 8 groups of 10 specimens each were evaluated. All specimens were thermocycled for 5000 cycles, in water baths between 5 and 55 C. Half the specimens in each group were treated with cyclic loading at 50N for 14, 400 cycles at 1.2 Hz. The shear bond strengths were measured using a Universal Testing Machine. Data were analyzed using Two-way ANOVA test.

Results: Statistical analysis demonstrated no significant effect of cyclic loading on the shear bond strength, but the type of artificial tooth affected the shear bond strength (P=0.006). Also, the interaction between Cyclic loading and the type of artificial tooth showed no significant difference (P=0.98). Tukey test showed that acrylic teeth (Ivoclar) had statistically higher bond strength values than that of other teeth (PGlamour=0.02), (PComposite ivoclar=0.01) and (PMarjan new=0.02).

Conclusion: Within the limitation of this study, the predominant type of fracture in all groups was cohesive, therefore the bond strength was adequate in all teeth and the type of artificial tooth may influence the bond strength of denture teeth to denture base resin. Cyclic loading had no significant effect on the bond strength of denture teeth to the auto-polymerized acrylic resin.


Daryosh Goodarzipour, Allahyari Nezad, Bahareh Purtaji, Yasaman Mohemkar Kheirandish,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Because of high prevalence of TMJ dysfunctions , increased promotion of diagnostic and treatment methods is necessary. In many cases, in addition to disc position, morphology of other joint components such as articular eminence can be changed and therefore the probable correlation between disc position and morphology of hard tissue components can be used for prediction of internal derangements. The aim of this study was to evaluate the correlation between the position of disc and morphology of articular eminence of TMD`s patients using magnetic resonance imaging (MRI).

 Materials and Methods: In this cross sectional study by evaluation of digital MRI files, ultimately 78 joint images were identified which had sufficient quality and resolution for review. Then the MRI images, were observed and evaluated by 3 oral and maxillofacial radiologists to determine the disc position (normal, anterior displacement with and without reduction, and posterior displacement) and morphology of articular eminence (Box, Sigmoid, Flattened). Ultimately the results that were reported at least by 2 observers were included as the final results and were recorded in the check list. Data were analyzed using Chi-Square test and Fisher test.

 Results: In this study, no case of posterior disc displacement was found and therefore was excluded from the study. Articular eminence morphology (Flattened versus Sigmoid) showed statistically significant correlation with anterior disc displacement with and without reduction (P-values for anterior displacement with and without reduction were 0.03 and 0.002, respectively). No significant difference was found between the sigmoid and box types in relationship with disc displacement (P-values for anterior displacement with and without reduction were 0.72 and 0.70. In this study, no significant difference between the anterior disc displacement with reduction and anterior disc displacement without reduction in relationship with the morphological changes of articular eminence in any of the cases were found.

 Conclusion: The results showed that flattening of articular eminence had significant relationship with anterior disc displacement.


Mahshid Mohammdi Basir, Elham Tabatabai Ghomsheh, Abbas Azari, Zahra Malek Hosseini, Majid Vahdati Far,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Endodontically treated teeth are prone to fracture because they loose a big amount of their structure. The treatment plan of those teeth is completed when they are rehabilitated with a strong and functional restoration. The purpose of this study was to evaluate the fracture resistance of endodontically treated teeth restored with amalgam cuspal coverage in comparison with other restorative techniques.

Materials and Methods: 40 human healthy maxillary premolars were divided into 4 groups: group1 (S): sound teeth, group 2(Co): endodontically treated teeth with MOD cavity restored with bonding and composite, group 3(Am-B): endodontically treated teeth with MOD cavity restored with bonding and amalgam and group 4 (Am-CC): endodontically treated teeth with MOD cavity restored with amalgam cuspal coverage. Then the restorations were stored in water and room temperature for 100 days at then thermocycled for 500 cycles between water baths at (5.5 ± 1) and (55 ± 1) 0 C. The fracture resistance was evaluated by universal testing machine (Instron, 1195 UK) with the compressive force of about 2000 N in 0.5 mm/min. The fracture modes were evaluated in four groups by a stereomicroscope. Statistical analysis (Scheffe test) was done for all groups (P<0.05 was considered as the level of meaningfulness).

Results: The highest fracture resistance was found in group 4 (Am-CC) (976 ± 23.27 N) that had no significant difference with sound tooth (P>0.05). The lowest fracture resistance was found in group 2 (Co) (384 ± 137.4 N) that had no significant difference with group 3 (Am-B) (P>0.05). The fracture resistance in group 4 was significantly higher than group 2 (Co) and 3 (Am-B). The fracture mode in group 1 was cohesive within tooth and in group 2 (Co) and 3 (Am-B) was mixed cohesive and adhesive, and in group 4 was cohesive within in restorative material.

Conclusion: The highest fracture resistance was found in teeth that received amalgam cuspal coverage.


Farin Kiani Yazdy, Masoud Golshah, Mahboobeh Razmkhah, Abbas Ghadery,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Apoptosis or programmed cell death plays an important role in the pathogenesis of many diseases. Previous studies suggest that apoptosis is involved in the pathogenesis of periodontal disease, on the other hand it is also suggested that diabetes mellitus enhances apoptosis of connective tissue cells. Thus, we measured expression of proteins which are relevant to apoptosis in the gingival tissue of diabetic patients with chronic periodontitis in comparison to non diabetic individuals.

Materials and Methods: 25 patients with diabetes and chronic periodontitis and 16 non diabetic controls were included in this study. 4 weeks after scaling and root planning and oral hygiene instructions, periodontal surgery was done and gingival tissues obtained during surgery, were sent to lab to investigate expression of Fas, P53, Bcl-2 and Survivin using real-time PCR technique. Data were analyzed using Mann-Whitney and Chi-squared.

Results: Pro-apoptotic proteins (Fas, P53) were significantly (P<0.05) higher in gingival tissues of diabetics (9.5×10-6, 2.4×10-6, respectively) in comparison to non diabetics (9.4×10-7, 5.6×10-7), whereas the difference in expression of anti-apoptotic proteins (Bcl-2, Survivin) between 2 groups was not significant (9.7×10-8, 3.5×10-7 in comparison to 1.4×10-7, 3.1×10-7, respectively)( P =0.91, P =0.29 respectively).

Conclusion: Apoptosis was increased in gingival connective tissue of diabetic patients with chronic periodontitis in comparison to non diabetic ones. Therefore , intervention in expression or function of pro-apoptotic proteins (Fas, P53) could be a new goal in the treatment of periodontal disease of diabetic patients.


Omid Aminian, Zahra Banafsheh Alemohammad, Khosro Sadeghniiat Haghighi,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Regarding the diversity of reported low- back pain among dentists in different countries and lack of control group in most of the previous studies, the purpose of this study was to compare low- back pain and related risk factors between male general dentists and pharmacists to determine the relation between dentistry and development of low back pain.

Materials and Methods: In this cross-sectional study, 261 male dentists were compared with 193 male pharmacists as a control group with Standardized Nordic Questionnaire (low back section). Subjects were at least one year in clinical practice after becoming qualified and did not suffer from connective tissue diseases and history of a traumatic event causing fracture in spinal column. The data were analyzed by Chi- square, T-test and logistic regression analyses.

Results: The prevalence of low back pain in the past 12 months was 54.8% in male dentists and 36.3% in male pharmacists (P=.001). Logistic regression analyses, adjustmenting for occupation, age, body mass index (BMI), smoking, working years and working hours per week, revealed that there was a significant association between being a dentist and having low- back pain (OR=2.54, P=0.001).

 Conclusion: Dentistry as a profession in male gender is associated with low back pain, independent of age, body mass index (BMI), smoking, working years and working hours per week.


Alireza Daneshkazemi, Abdolrahim Davari, Majid Mousavinasab, Alireza Zahedifar,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Today, use of adhesive systems is the most common materials in restorative dental procedures. The aim of this study was to evaluate the effect of different air-drying periods on the microtensile bond strength of composite to dentin using adhesive.

Materials and Methods: 15 sound molar teeth were selected. The an occlusal surfaces of teeth were removed with silicon carbide disks (3M/USA) to reach flat surface of dentin. Then according to the air drying of solvent, the teeth were divided to five groups. After 5 sec etching and rinsing for 15 sec , the teeth were air dried for 3 sec . Then Singlebond (3M) was used with different air-drying times (0s, 2s, 5s, 10s, 30s) and cured. Then after insertion and curing of Saremco (microhybrid low shrinkage/Switzerland) composite, the teeth were thermocycled for 500 cycles. Then hour glass slabs with 1 mm2 interface was created. Specimens were then subjected to µTBS force until fracture. Data were analyzed using ANOVA and Bonferroni tests.

Results: Statistical tests showed that there were significant differences between bond strength of groups (P=0.002). The mean of µTBS for the 2 Sec and 30 Sec evaporating time was the most and the least vawes, respectively.

Conclusion: An optimum air-drying time for solvent evaporation was the lowest time recommended by the manufacturer. Over and under evaporation time decreased µTBS significantly.


Mehdi Jafarzadeh Samani, Maryam Hajiahmadi, Samira Yousefi, Elham Sadat Binande,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Successful pediatric dentistry depends not only on the dentist's technical skills, but also on his ability to acquire and maintain a child's cooperation. The correction of dentist’ action in this area affects the view of parents and increases the quality of dental services. The objective of this study was to evaluate the attitudes of general dentists toward methods of controlling pediatrics’ behavior in Isfahan.

Materials and Methods: This study is descriptive, analytic, and cross-sectional. For this research, 100 general dentists of Isfahan city were selected with simple random sampling technique and were asked to complete the questionnaire which was included four different management techniques. The data were analyzed with t-test, P earson’s correlation , ANOVA and Kruskal-Wallis.

Results: The methods accepted by dentists were Tell-Show-Do (4.0 ± 0.5), Voice control (3.5 ± 0.4), active restraint (3.0 ± 0.5) and Hand-Over-Mouth (2.9 ± 0.5) respectively. The mean score of female dentists’ attitudes was more toward the method of active restraint and less toward Hand-Over-Mouth technique. Also the average score of middle aged dentists’ attitudes toward Voice Control method was less than young dentists and toward Hand-Over-Mouth was higher. The general dentists with more number of pediatric patients had less consent on the method of Hand-Over-Mouth (P=0.004) and active restraint (P=0.034).

Conclusion: There were significant correlation between attitude of general dentists toward behavior management techniques with age, gender, clinical experience and the number of pediatric patients. General dentists have fewer tendencies to aggressive behavior management techniques.


Sahar Ghodsi Bushehri, Farzaneh Khajeh, Somayeh Heidari, Shahla Momeni Danaei,
Volume 26, Issue 2 (5-2013)
Abstract

Background and Aims: Skeletal class III malocclusions are considered as one of the most complex and difficult orthodontic problems to diagnose and treat. Facial appearance and occlusion problems make the patients to seek treatment as soon as possible. The purpose of this study was to evaluate the outcomes of early treatment with facemask compared to the patients who had no treatment.

Materials and Methods: For this retrospective study, 38 growing patients (mean age, 8.5 years old) with class III dentoskeletal malocclusion were divided into 2 groups. 23 patients were treated with facemask and 15 patients who did not receive any treatment were assigned as control group. Lateral cephalograms were taken before and after treatment and dentoskeletal changes were estimated. Data were analyzed using Wilcoxon signed ranks test.

Results: The results revealed statistically significant forward displacement of maxillary bone and upper incisors (P<0.001), and downward-backward rotation of mandible in facemask group (P<0.001). Increased lower facial height was seen in both treatment and untreated groups. However, in untreated group some measurements revealed forward displacement of maxillary complex as well.

Conclusion: It seems that in class III patients treating with facemask is a better choice than ChinCap and decision making for early treatment in class III patients should be considered seriously. Moreover, specific attention to the type of patient’s skeletal discrepancy is necessary. In class III patients, facemask might be a better option than other appliances.


Mahsa Mansouri , Khoroushi Maryam ,
Volume 26, Issue 3 (8-2013)
Abstract

  U ntreated caries are common findings in low-income communities. Treatment of dental caries in young children is challenging and requires a high skill and high cost of dental anesthesia for control ling patients and thus, chemical methods for arresting dental caries have been proposed. Silver Diamine Fluoride (SDF) is a material that is used to control and to arrest dental caries , especially in primary teeth . It is noninvasive, safe , easy to use , and cost-effective. The SDF can be used as a therapeutic agent in oral health projects in low-income communities . In this article we review ed the silver diamine fluoride and its application in dentistry.


Eshagh Ali Saberi, Fereydoon Sargolzaei Aval , Arab Mohammad Reza Mohammad Reza , Seddighe Ebrahimipour ,
Volume 26, Issue 3 (8-2013)
Abstract

  Background and Aims: The purpose of this study was to evaluate the tissue responses to octacalcium phosphate (OCP) and calcium hydroxide (CH) used as direct pulp capping (DPC) materials in cat teeth.

  Materials and Methods: 72 premolar teeth of 9 cats were selected and divided into 3 groups (Two experimental and one control group). After the cats had been anesthetized, the pulp were exposed and capped directly with OCP, CH or no capping material as control group. The cavities of all three groups were filled with Glass ionomer cement (GI). Histological evaluations were performed at two, four and eight weeks after pulp capping. After tissue preparation procedures, paraffin blocks were prepared. After preparation and staining of the sections, the relevant variables were measured by optical microscope. The results were analyzed using Mann-Whitney U and Chi-square tests ( α =0.05).

  Results: Two weeks after pulp capping, all specimens in three groups showed mild to sever inflammation. The formation of hard tissue (dentinal bridge) at in the exposed areas of the experimental groups was more noticeable for calcium hydroxide than that of octacalcium phosphate group. These differences were statistically significant (P<0.001). At four weeks, hard tissues were observed in both groups which were more evident for the CH group and there were statistically significant difference between two experimental groups (p<0.003). At eight weeks, continuous hard tissues were observed in both groups and there were no statistically significant difference between them (P>0.05), but hard tissues continuity were better for in the OCP than that of the CH.

  Conclusion: It seems that the formation of hard tissue in CH because of its porosities had a worse percentage in sealing of the pulp than the OCP .


Mahshid Mohammdi Basir, Elham Tabatabai Ghomsheh, Mohammad Bagher Rezvani, Zeinab Rafie , Zahra Malek Hoseini,
Volume 26, Issue 3 (8-2013)
Abstract

  Background and Aims: The purpose of this study was research on a new herbal compound (Seidlitzia Rosmarinus) made by Traditional Medicine Research Group, University of shahed to find a safer alternative to HCL-Pumice compound technique.

  Materials and Methods: In this randomized clinical trial seventy two anterior teeth from 9 patients were divided in to three groups according to fluorosis severity: mild (34 teeth), moderate (14 teeth), and sever (24 teeth). In each patient, half of the teeth were treated with “Shahed” compound and other half treated with HCL-Pumice compound. Before and after treatment, photographs were taken in both groups. HCL-Pumice treatment compound was applied for 30 seconds periods and continued for 10 minutes if necessary. In case of herbal Shahed compound the time was determined by clinical symptoms or when labial contour was dismissed, If the result was not esthetistically acceptabale for the patient, HCL-Pumice compound was applied on teeth. NaF was applied after mouth washing. The photographs of the teeth before and after treatment were reviewed by two experienced observer unaware of the treatment modality. The results were analyzed using willcoxons, kruskal-wallis and scheffe test.

  Results: There was over 81.3% acceptance between two observers and no significant differences in intraobservers evaluation (P>0.05). Improvement in beauty indexes were observed in all degrees of dental fluorosis by 18% with HCL-Pumice compound application, but “Shahed” herbal compound induced significant reduction in the amount of white spots in mild fluorosis and stain intensity of moderate fluorosis (P<0.05) , while the reduction in the severity of discoloration in group 2, these two techniques were statistically equivalent but in the remainder, HCL-Pumice compound was more significantly effective (P<0.05) .

  Conclusion: HCL-Pumice compound reduces the severity of the discoloration of the teeth. Shahed herbal compound cannot reduces the discoloration like as HCL-Pumice compound.


Marzieh Alikhasi , Razieh Khanmohammadi, Somayeh Niakan ,
Volume 26, Issue 3 (8-2013)
Abstract

  Background and Aims: Along with the advances in dental materials and invention of new techniques for ceramic producion, the demand for the beauty and matching restoration’s color with patient’s natural teeth is growing. Nowadays, zirconia systems are the focus of attention. Despite their strength, one of the problems with such systems is the high opacity and failing to provide the favored color. Considering few studies about the influence of shading on Zirconia, the purpose of this in vitro study was to evaluate the effect of different shading of zirconia-based ceramics on the biaxial flexural strength .

  Materials and Methods: In this in vitro experimental study, Rainbow (Dentium, Korea) zirconia-based ceramics (the diameter of 15mm and 1mm in thick) were divided into four groups of 10 specimens. According to Vita shade guide system and manufacturer’s time recommendations (3 seconds), three groups of disc specimens were shaded to A3, B3 and D3 colors and other ten specimens remained uncolored as control group. The biaxial flexural strength test of discs was evaluated and the elements’ composition of colors was detected by Energy Dispersiue X-ray Microanalysisd (EDX). Finally, data were analyzed using one-way ANOVA and Post-hoc tests.

  Results: The biaxial flexural strength in non colored specimens, A3 shaded discs, B3 shaded, and D3 shaded specimens were determined 1061.93, 819.16, 1100.10, and 825.48 MPa respectively which was statistically significant among groups (P<0.001). The statistical analysis revealed that the highest strength in B3 and non colored groups which were significantly higher than A3 and D3. EDX analysis showed significant differences among different colored compositions.

  Conclusion: The biaxial flexural strength of zirconia cores are affected by shading and the specific selected color.


Davari Abdolrahim , Kazemi Alireza Danesh , Mousavinasab Majid , Mohammadi Najmeh Pour ,
Volume 26, Issue 3 (8-2013)
Abstract

  Background and Aims: Different adhesives with different solvents may have different solvent evaporation rates. The purpose of this study was to evaluate the solvent evaporation in the self etch and total etch adhesive in different air drying times.

  Materials and Methods: Five adhesives were used in this study: Excite, Prime & Bond NT, UNO, Single Bond, SE Bond Primer. Twelve drops of each adhesive were used for each period of air drying (5, 15, 30 sec). The percentage of mass loss was measured during each test. Data were analized using two-way ANOVA and Tukey.

  Results: Acetone base adhesives showed more loss of mass than other adhesives (P<0.01). P&B NT showed more loss of mass than other adhesives in all air drying times (P<0.01). Adhesives showed different evaporation rates in different air times (P<0.01).

  Conclusion: Adhesives with acetone/water or alcohol/water solvent shows more stable behavior in comparison with adhesives containing pure aqueous solvents.



Page 36 from 53     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb