Search published articles


Showing 4 results for Blood

V. Mortazavi , Mh. Fathi , Aa Ajami ,
Volume 18, Issue 2 (5-2005)
Abstract

Statement of Problem: Blood contamination is a common problem in dentistry that can decrease bond strength dramatically which may be affected by methods of decontamination as well.

Purpose: The aim of this study was to evaluate and compare the influence of blood contamination on shear bond strength of composite and compomer to dentin using Prompt L-Pop as an adhesive system. Also, to assess the effectiveness of different surface treatments on the bond strength.

Materials and Methods: In this experimental study, 120 molar teeth were sectioned to provide flat occlusal dentinal surfaces. Specimens were embedded in acrylic resin with the flat surface exposed. The dentinal expose surfaces were polished to 600 grit. The teeth were randomly divided into five groups of twelve specimens (F1–F5) for compomer material and five other groups (Z1- Z5) for composite resin. After application of Promt L-Pop to dentinal surfaces of specimens, the surfaces in all groups, except for F1 and Z1, (as controls) were contaminated with human blood and then one of the following surface treatments was applied. Groups F2 and Z2 without any treatment, groups F3 and Z3 rinsing with water, groups F4 and Z4 rinsing with water and reapplication of adhesive, groups F5 and Z5 rinsing with NaOCl and using Prompt L-Pop again. Restorative materials were applied to treated surfaces using plastic molds. After thermocycling, shear bond strengths, mode of failures and morphology of dentin-material interfaces were evaluated. The data were statistically analyzed using Factorial analysis of Variance, One-Way ANOVA, Duncan, T-student and Chi-Square tests with P<0.05 as the limit of significance.

Results: Compomer showed statistically significant higher bond strength in comparison to composite (P<0.001). Duncan test showed significant differences between all compomer groups, except between groups F4 and F5, and between all composite groups except for groups Z1 and Z4 and for groups Z2 and Z3.

Conclusion: Based on the findings of this study, shear bond strength of compomer material was significantly higher than composite. Blood contamination reduced bond strength, but rinsing contaminated dentin with water or NaOCl and reusing Prompt L-Pop increased bond strength in both materials.


M. Tabrizizadeh , F. Boozarjomehri , Mh. Akhavan Karbasi , F. Maziar ,
Volume 19, Issue 1 (4-2006)
Abstract

Background and Aim: Lead is one of the most dangerous metallic poisons which can lead to acute and chronic poisoning with a broad range of systemic and oral signs. The aim of this study was to evaluate the relationship between the prevalence of oral complications and blood lead level in workers employed in Koushk lead mines, Yazd province.

Materials and Methods: This analytical study was conducted on 70 subjects employed in Koushk lead mines and 70 workers in Yazdbaf textile factory as control group. A questionnaire including demographic information and medical questions was completed for each case and oral manifestations were recorded, as well. Blood samples were taken from subjects and blood lead level was measured by atomic absorption spectrophotometer. Data were analyzed using t, Chi-Square and Mann Whitney tests with p<0.05 as the limit of significance.

Results: The mean lead level was 7.06 µg/dl in case group and 4.97µg/dl in control group (P= 0.039). In case group, 3 subjects had blood lead level more than 20µg/dl. Statistical analysis showed significant differences regarding neurologic disorder, chronic fatigue, existence of lead line, mucous pigmentation, gingivitis, tongue burning, taste sense reduction and DMF between case and control groups (P<0.05).

Conclusion: Based on the results of this study, since the mean blood lead level in mine workers was in normal limits, the observed symptoms were not related to systemic poisoning. Direct contact of the oral mucosa with the lead in breathing air or other factors related to overall health problems in mine workers may be responsible for the present findings. Further studies are recommended on similar subjects working in different conditions.


Ms. Sheikhrezaie, Mh. Nekoofar, K. Oloomi,
Volume 21, Issue 4 (1-2009)
Abstract

Background and Aim: One of the unique properties of MTA is its setting ability in presence of moisture. The sealing ability of MTA used as a root-end filling was shown to be unaffected by the presence of blood, in vitro. It has been recommended that, because of MTA ability to set in the presence of blood, there is no need to dry the perforation site before MTA placement. On the other hand, based on an in vitro study, it is recommended that hemorrhage be controlled at the perforation site and blood be removed from the perforation walls before placement of tooth-colored MTA. Blood contamination may also affect the crystalline structure of MTA. The microhardness of a material is influenced substantially by some fundamental properties of the material such as crystal structure stability. Thus, it can be used as an indicator of the setting process. It can also indicate the effect of various setting conditions on the overall strength of a material. The aim of this study was to evaluate the effect of blood contamination on microhardness of white and gray MTA as an indicator of their setting process.

Materials and Methods: In groups 1 and 2 each material has been mixed with distilled water according to manufacturer,s instruction (No contamination groups). In groups 3 and 4 samples were prepared like groups 1 and 2 but the surface of material placed in contact with blood (Surface blood contamination groups). Samples of groups 5 and 6 were mixed with blood instead of distilled water and also the surfaces of the materials were placed in contact with blood (Mixed with blood groups). All samples were stored in 370C and 100% humidity for 96 hours. The microhardness of the samples was measured with Vickers test.

Results: White MTA samples which have not contaminated with blood had the highest microharness (59.9±11.4 N/mm2) while gray MTA mixed with blood had the lowest hardness (18.45±7.8 N/mm2). One-way ANOVA test showed that contamination with blood significantly reduces the microhardness of both white and gray MTA (p<0.001). The difference between white MTA and gray MTA was significant in groups of no contamination (p<0.001), surface blood contamination (p=0.043), and mixed with blood (p<0.001) according to T-Test analysis. In all of them white MTA had higher hardness than gray MTA.

Conclusion: According to results of our study we recommend that hemorrhage should be controlled and any blood contamination should be removed before placement of both white and gray MTA.


Noushin Shokouhinejad, Hassan Razmi, Mehrfam Khoshkhounejad, Pegah Firouzmanesh,
Volume 30, Issue 3 (10-2017)
Abstract

Background and Aims: The aim of this study was to assess the microhardness of BioMTA (OrthoMTA, RetroMTA) in distances of 0.5, 2 and 3.5 mm from the exposed surface to blood, phosphate buffer saline (PBS) or distilled water and to compare to that of ProRoot MTA.
Materials and Methods: One hundred and thirty five semicylindrical polymethyl methacrylate were filled with either ProRoot MTA, OrthoMTA, or RetroMTA. Fifteen molds in each group were exposed to blood, 15 molds to PBS and the other 15 to distilled water. The microhardness of the materials at 0.5, 2 and 3.5 mm distance from the exposed surface to phosphate-buffered saline (PBS) as a synthetic tissue fluid, blood, and distilled water was assessed. The data were analyzed using one-way ANOVA and Tukey post hoc tests.
Results: Exposure to blood significantly decreased the microhardness of all materials at all three points of 0.5, 2 and 3.5 mm (P<0.001). At level of 0.5 and 2 mm distant from blood, OrthoMTA showed significantly the least microhardness value; however, at the point of 3.5 mm, the microhardness of RetroMTA was higher than the two other materials (P<0.001). After exposure of samples to distilled water or PBS, no significant difference was found between the materials at any levels of 0.5, 2, and 3.5 mm (P<0.01).
Conclusion: Blood exposure resulted in the decrease of microhardness of internal part of the materials.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb