Search published articles


Showing 7 results for Bonding Agents

A. Pahlevan , Sh. Rahebi ,
Volume 15, Issue 3 (6-2002)
Abstract

Dentin bonding agents create stronger bonding between dental composites and dentin. But, none of them can prevent the microleakage. The important factors of progressing microleakage are the stress of polymerization shrinkage of resin composite and removal of smear layer in total-etch technique. The aim of this study was the evaluation of the effect of experimental method (modifying smear layer and etching of enamel margin) and comparison with the total-etch technique. In this experimental method, 60 extracted human molar teeth were disinfected. Then, class 5 cavities were prepared on the buccal surface and 1 mm above CEJ. The specimens were divided randomly to 6 groups with iO samples in each group. The specimens groups were:
1- Scotchbond Muiti- Purpose Plus Adhesive System (S.B.M.P.P) +Tetric composite
2- S.B.M.P.P + Ariston composite
3- Ariston liner + Ariston composite
4- S.B.M.P.P without enamel and dentin etching + Tetric composite + rebonding with Flowable Tetric
5- S.B.M.P.P without enamel and dentin etching + Ariston composite + rebonding with Flowable Tetric
6- S.B.M.P.P without enamel and dentin etching + Tetric composite
After finishing and polishing, the specimens were termocycled, stained with fushin, sectioned within the specimens and evaluated for dye penetration with stereomicroscope. Wilcoxon Sign and Kruskal Wallis tests were used for statistical analysis.
Results showed that group 3 had microleakage more than groups of 1, 2 and 5 (P<0.0 5) and this difference was significant. There was no significant difference among the other groups.


F. Shirani, Mr. Malekipor, F. Aghaei,
Volume 21, Issue 3 (12-2008)
Abstract

Background and Aim: Fractured anterior teeth can be restored by adhesive bonding of the separated fragment to the remaining tooth structure. This invitro study evaluated the force required for fracture of rebonded fragments which were dried and rewetted for various time intervals prior to bonding.

Materials and Methods: One hundred and eight human mandibular incisors were selected and were divided into 9 groups and then were fractured. The fragments were stored in air at room temperature and ambient humidity. They were air dried for 30 minutes in group 1, 2 and 3,  6 h in group 4 and 5,  24 h in group 6 and 7, and 3 days in groups 8 and 9. The apical parts of the fractured teeth were stored in water.After storage in air, each fragment in group 1 was bonded to the remaining apical tooth structure with a bonding agent and flowable composite.In groups 2, 4, 6 and 8 after air drying the fragments were stored in water for 30min. The time of storage in water in groups 3, 5, 7, 9 was 24 hours. Then each fragment was bonded to the apical part structure. The mean force required for fracture was measured by a mechanical testing machine. One way ANOVA and Tuckey tests were used for analysis.

Results: There were statistically significant differences between different groups (p<0.001).The highest and lowest force required for fracture belonged to groups 3 and 8 respectively. The force required for fracture in group 1 was lower than group 2, 3, 5 and 7 and 9 and more than groups 4,6 and 8 with significant differences.While there were no significant differences among groups 3, 5, 7, 9 and 4, 6, 8 the force required for fracture in groups 2, 3, 5, 7 and 9 was more than 4, 6, 8 with significant differences.

Conclusion: This research revealed that the force required for fracture was affected by air storage of fragments prior to bonding. Also showed that with an increase in duration of drying the force required for fracture decreased and after a period of time it becomes steady. This study showed that in order to increase the fracture strength after air drying the fragment should be immersed in water for at least 24 hours prior to bonding.


M. Karami Nogourani, P. Khadem Abbakhshani, Z. Jadidi, G. Amirpoor,
Volume 22, Issue 1 (8-2009)
Abstract

Background and Aim: Since the clinical studies conducted to explore the effect of bonding agents on the success of fissure sealant are limited in number, the present study was conducted to compare the effects of two bonding agents on the success of fissure sealant of the saliva- contaminated teeth.

Materials and Methods: In this study, 63 teeth of 35 students aged 6-8 with healthy and newly-erupted upper jaw molar teeth, were selected and divided into two groups. In one group, single-bond and In the other, SE bond were used. As the teeth were newly erupted and the distopalatal area being in contact with the gingival sulcus and this fact that, this area was impossible to isolate, the distal sulcus of the contaminated teeth and the mesial area capable of adequate isolation were assumed isolated. For each group, after etching, the teeth on one side were treated with a sealant and the teeth on the other side were first bonded and then treated with the sealant. Hence, four groups were formed: bonded/isolated, bonded/contaminated, controlled/isolated and controlled/contaminated for any bonding agent. The results of the treatment were assessed in terms of the success and failure and then analyzed using Mc Nemar, and Chi-square tests and Cochran.

Results: The results of the study indicated that:1. Saliva contamination caused a significant increase in sealant failures(p<0.05).2. Use of the two bonding agents significantly increased the success of the sealant(p<0.05).3. Use of the two bonding agents significantly increased the success of the fissure sealant on the saliva-contaminated teeth, even more than when the teeth had been isolated and with only fissure sealant(p<0.05). 4. For the contaminated enamel, the results of SE bond were better than those of the single bond (p<0.05). However, in isolated condition the results of using single bond were better (p<0.05).

Conclusion: The results of the study supported the use of these two bonding agents in the treatment of fissure sealants under both isolated and contaminated conditions. Further, more SE bond seemed to be less sensitive to saliva contamination.


T. Jafarzadeh Kashi, M. Erfan, A. Nezadi Niasar,
Volume 22, Issue 3 (12-2009)
Abstract

Background and Aim: Evaluation of shear bond strength and microleakage of bonding agents is important as these properties play main roles in adhesion of composite to dental tissues. Microleakage results in bacterial penetration into dentin tubules and enamel surfaces and causes sensitivity and recurrent caries followed by destruction of composite filling. Insufficient shear bond strength results in early failure of filling in low masticatory forces. The main goal of this study was to compare the microleakage and shear bond strength of an experimental adhesive and Scotchbond multi-purpose (MP) adhesive system.
Materials and Methods: In this experimental study, sixty extracted caries free human molar teeth were randomly assigned into 4 groups of 15 each for shear bond strength. Variables were bonding agents, enamel and dentin. Twenty teeth assigned into 2 groups of 10 each were used for valuation of the microleakage. Microleakage and shear bond strength were performed according to ISO TR 11405. All data were analyzed with parametric and non-parametric tests according to their normality distribution. Also, Weibull distribution performed on data.
Results: Data obtained from both microleakage and shear bond strength tests showed no significant difference between the experimental bonding and Scotchbond MP bonding (P>0.05). Furthermore, there was no significant difference between the microleakage of occlusal and gingival parts of both bondings (P>0.05).
Conclusion: Experimental adhesive bonding showed acceptable results regarding microleakage and shear bond strength. It may be concluded that the experimental dentin bonding had a comparable performance quality with that of commercial system.


Farimah Sardari, Marjaneh Ghavam Nasiri, Nasrin Amini, Berahman Sabzevari,
Volume 25, Issue 3 (7-2012)
Abstract

Background and Aims: The aim of this in vitro study was to assess the shear bond strength of amalgam to dentin using four dentin adhesive systems.
Materials and Methods: One hundred human molars were selected. After enamel removal, a dentin cylinder with 3 mm thickness was prepared. Eighty specimens were resorted with amalgam and four dentin adhesive systems as follows (n=20): group 1, Scotch Bond Multi-Purpose group 2, One Coat Bond group 3, PQ1 and group 4, Panavia-F. In group 5, 20 specimens were resorted with amalgam and varnish as control group. The specimens were incubated at 37°C for 24 h. The shear bond strengths were then measured by using push out method. The data were analyzed by one-way ANOVA and post hoc Duncan's tests.
Results: Mean values for bond strengths of test groups were as follows: group 1=21.03±8.9, group 2=23.47±9, group 3=13.16±8.8, group 4=20.07±8.9 and group 5=14.15±8.7 MPa±SD. One-way ANOVA showed the statistically significant difference between the bond strengths of five groups (P=0.001). Post hoc Duncan's test showed significant difference between groups 1and 3 (P=0.008), groups 1 and 5 (P=0.019), groups 2 and 5 (P=0.0008), groups 4 and 5 (P=0.042), and groups 3 and 4 (P=0.018).
Conclusion: Results of this study showed that the bond strength of amalgam to dentin using One Coat Bond as dentin adhesive system was higher than that observed in other dentin adhesive systems.


Salari Behzad , Shahabi Sima , Bagheri Hossein , Yousefi Mahsa ,
Volume 26, Issue 4 (1-2014)
Abstract

  Background and Aims : The aim of this study was to evaluate the effect of chlorhexidin 2%, sodium hypochlorite 2.5% and hydrogen peroxide 3% as three effective and regular disinfectants on the microleakage of 7th generation bonding agents in vitro.

  Materials and Methods: 45 extracted molar teeth without carries were collected and disinfected. On buccal and lingual aspects of these teeth conventional class V cavity preparation were done (90 cavities), then randomly divided to 4 groups, three of them had 10 teeth (20 cavities) and one of them had 5 teeth (10 cavities) as control group. Cavities in each experimental group prepared with one of the disinfectants and then 7th generation bonding (Optibond all in one, kerr) was used as noted by manufacturer, then cavities filled with composite and polished. Bonding agent was used without our previous disinfectants manipulation in control group. Specimens were thermocycled with 1000 thermal cycles between 5 and 55 0 C each for 30 seconds and then immersed in the methylene blue 5%, then sectioned mesiodistally and investigated for microleakage under stereomicroscope (Olympus, Japan). Data were analyzed using Kruskal-Wallis and Wilcoxon mean rank tests.

  Results: Despite the lower mean rank values for the untreated group at both occlusal and gingival aspects, the Kruskal-Wallis procedure (α=0.05) showed that the treatment factor did not significantly affect the mean rank values neither in occlusal (P=0.12) nor in gingival (P=0.39) part of cavities.

  Conclusion: According to the results of this study, antimicrobial agents such as chlorhexidine 2%, sodium hypochloride 2.5% and hydrogen peroxide 3% can be used perior to 7th generation dentin bonding agent
(Optibond all in one, kerr) without much concern.


Saeed Nemati Anaraki, Hamed Karkehabadi, Nazanin Zeinab Garshasb Zadeh,
Volume 29, Issue 1 (7-2016)
Abstract

Background and Aims: Microleakage is one of the most common problems in bonding systems, which cause different clinical shortcomings such as post operative sensitivity, marginal discoloration and pulp necrosis that can decrease those using bonding systems. The aim of this study was to compare the microleakage of three self etch bonding agents (generation 6 and 7) in class 5 composite cavities.

Materials and Methods: In this experimental study, 30 facial class 5 cavities were prepared in 30 human premolar teeth which were freshly extracted for orthodontic purposes. Cl V cavities were prepared in 2*3*2 mm dimensions. Occlusal margins were in enamel and gingival ones in cementum and randomly divided into 3 groups of 10 each. Then the cavities were treated by clearhil SE Bond (Kuraray, Japan), G Bond (GC, Japan), and Opti Bond Solo Plus (Kerr, USA), according to the manufacturers’ insductions. Then the cavities were filled using Z100 resin composite. The specimens were then immersed in a 50% AgNo solution for 24 hrs. Then, the teeth were cut buccolingually to be evaluated for dye penetration with stereomicroscope. Data were analyzed using Kruskal-Wallis test.

Results: This study revealed that Opti bond solo plus had type1 microleakage (dye penetration up to 1/3 of cavity) in 80% of specimen, and type 4 microleakage (along axial wall) in 10%. Clearfil SE bond had no leakage in 50%, type1 in 40% and type 2 (up to 2/3 of cavity) in 10%. But there was no significant difference in the microleakage at the gingival margins between 3 groups (P>0.05).

Conclusion: Clearfil SE Bond and G bond could prevent microleakage more effectively than that of Opti Bond Solo Plus on the occlusal margins. However, no difference in the microleakage on the gingival surfaces was found.



Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb