Showing 10 results for Digital Radiography
Ar. Talaeipour , Gh. Mohammadian , D. ghoudarzi ,
Volume 14, Issue 2 (8-2001)
Abstract
Osteodystrophy is one of the most common complications at the last stage of renal disease,which cause low bone mineral density (BMD) and skeletal deformities in patients. In this study evaluation of renal osteodystrophy was evaluated through BMD measurement of 45 under dialysis and 78 healthy persons by intra-oral digital radiography (RVG). Results Showed that:1- The average of BMD in hemodialysis patients was indeed lower than normal population (P^O.OOO).2- The mean of BMD of females was lower than males (P=0.021).3- There was no correlation between and BMD (P=0.560).4- Age and BMD had no significant relationship (P=0.648).5- There was negative correlation between alkaline and BMD therefore ALP is a useful predictive factor forBMD(P=0.002).
H. Bashizadehfakhar, A. Talaeepour , A. Dabbaghi ,
Volume 15, Issue 1 (3-2002)
Abstract
Nowadays, bone mass estimation, through imaging methods, is widely used in metabolic diseases diagnosis and treatment. One of these methods is called "optical densitometry" which estimates bone density by measuring the intensity of the transmitted light on different parts of a radiographic image. Digital radiography systems act similarly by determining grey levels of the image. The aim of this study is comparing two different methods of optical densitometry and a digital system densitometry known as radiovisiography. 45 samples, containing urografin with three different concentrations, were imaged, by both radiovisiogrphy (RVG) and conventional film systems. To determine the densitometry of films and radiovisiography images, optical densitometry and bone densitometry option of the RVG software, were applied respectively. Data were analyzed and compared for their reliability (repeatability) and correlations with concentration. In RVG densitometry system, the correlation with concentration is moderate (r=0.42) and intra samples and intra group reliability are 97.68% and 88.19%. Moreover, in conventional optical film densitometry, correlation with concentration (r=0.987) is high, intra samples and intra group reliability is high, intra samples and intra group reliability are 99.97% and 99.84%, respectively. According to the results, it is suggested that conventional film optical densitometry is more precise and reliable than RVG densitometry.
H. Bashizadeh Fakhar , Sa Fatemi Tabar ,
Volume 17, Issue 1 (4-2004)
Abstract
Statement of Problem: One of the major goals, in most dental researches, is to measure bone destruction or deposition due to the progression or regression of disease. Failure of human eyes to detect minor radiographic density changes resulted in more accurate methods such as optical densitometry and direct or indirect digital densitometry.
Purpose: The aim of this study was to determine the accuracy of a newly proposed method of indirect digital densitometry using modified Photoshop software.
Materials and Methods: Radiographs from 37 samples of urografin solution with three concentrations (12.5%, 25% and 37.5%) were taken on dental radiographic films no.2 and digitized by a scanner. A region with 800*800 pixels was cropped from each image and compressed with the Joint Photographic Experts Group (JPEG) compression algorithm and saved. These new images were then put into registration with new algorithm using MATLAB software version 6.1. This algorithm assigned each image and average pixel value (between 0 and 255). The association between concentration and calculated values for each image was tested with regression analysis and the meaning fullness of differences between calculated values was also analysis by ANOVA test. Tukey HSD and Alpha Krunbach were used whenever needs.
Results: Regression analysis revealed significant correlation between concentration and calculated average pixel value (r=0.883). The differences between average of pixels value for different concentration was significant (P=0.0001). Pixel values showed a good intra- sample and intra-group repeatability (Alpha Krunbach: a=99.96%, a=99.68%).
Conclusion: This method due to its high accuracy, easy usage and densitometer independency can be considered as a suitable alternative for conventional densitometry methods.
Ar. Talaei Pour , S. Mehralizadeh , A. Mesgarzadeh ,
Volume 18, Issue 1 (3-2005)
Abstract
Statement of Problem: Computed tomography (CT) has proved to be the most precise method to evaluate the quantity of jaw bones.In recent years, patient dose which is much more greater in CT than conventional methods has attracted more attention, and has brought the idea of using the conventional method in more accurate ways or applying new methods with lower doses.
Purpose:radiovisiography for presurgical evaluation of endosseous implants.
Materials and Methods: measured with the two aforementioned techniques. To determine the magnification factor, an acrylic stent with spherical lead markers with known diameter, has been used. Then in intra-operative phase, this distance was measured directly on the patient’s jawbone. To assess the significance of differences from radiography results and the gold standard the binomial distribution was used.
Results:significant and there was no significant difference between RVG and visual method.
Conclusion:to conventional tomography.
Radiography is the main tool for presurgical assessment of endosseous implants.The goal of this study was the assessment of the accuracy of conventional tomography andDistance between alveolar margin and superior border of mental foramen wasFindings showed that the differences between conventional omography and visual methods wereThis study revealed that the radiovisiography method showed more precise results in comparison
D. Goodarzi Pour, S. Nejati, A. Fotouhi,
Volume 24, Issue 1 (3-2011)
Abstract
Background and Aims: Conventional radiological equipments in our country are going to be converted to digital system using computed radiology (CR) technology. If we know the accuracy of digital panoramic radiography for detection of small defects in tooth, it will be useful in cases with difficulty for taking the intraoral radiographs. The aim of this study was to evaluate sensitivity and specificity of digital panoramic radiography for detection of proximal caries compared with the bitewing radiography.
Materials and Methods: One-hundred patients who had been ordered for taking both bitewing and panoramic radiography were included in this study. Panoramic and then bitewing radiographs were observed by a maxillofacial radiologist and interproximal caries were recorded. Sensitivity and specificity of digital panoramic radiography (CI=95%) was calculated compared with the bitewing radiography as a gold standard.
Results: This study showed that the values for sensitivity and specificity were 62.7% (CI 95%=57.7%-67.5%) and 91.0% (CI 95%=89.2%-92.5%), respectively.
Conclusion: Sensitivity of digital panoramic is less than bitewing radiography even with processing before printing. Therefore, bitewing radiography is superior for detection of inter proximal caries.
Sandra Mehralizadeh, Peyman Mehrvarzfar, Sima Taghizadeh, Maryam Edalat, Mahashad Mohebi,
Volume 28, Issue 2 (7-2015)
Abstract
Background and Aims: Diagnosis of vertical root fractures often poses a clinical dilemma. Diagnosis of VRF in intraoral radiographs, except in cases where the beam is perpendicular to the direction of fracture is difficult. Misdiagnosis often leads to wrong decisions about the design of teeth future treatment plan. The aim of this study was to determine the diagnostic accuracy of reverse contrast enhancement options in digital radiography, and to compare it with the original images to find a suitable method to detect vertical root fracture.
Materials and Methods: In this experimental study, digital radiography with phosphor plate detector was taken from 40 extracted single root teeth. From each intact and fractured tooth, the original and reverse contrast images captured and stored. Two expert observers viewed the images twice with an interval of two weeks. Diagnostic criteria (Accuracy, PPV, NPV, Specificity and Sensitivity) in form of absolute and complete for each observer and each images was calculated. Inter and intra observer reliability was obtained using Mc-Nemar test.
Results: No significant differences in inter-observer reliability between the initial appearance and reverse contrast was observed (P>0.05), but in view of the intra-observer reliability in two cases, the difference was significant (P<0.05). No significant difference in the accuracy, sensitivity, specificity and PPV was observe between the two used images (P>0.05), whereas significant difference between the two images was found in NPV index (P<0.05).
Conclusion: The use of reverse contrast enhancement option for detection of vertical root fracture did not show significant difference from initial view.
Mohtavipour Seyedeh Tahereh , Seyedeh Saeideh Mohtavipour, Alieh Sadat Javadzadeh Haghighat, Shiva Sadeghi, Maryam Rezvani, Bahar Mahmoud Khalesi,
Volume 29, Issue 1 (7-2016)
Abstract
Background and Aims: Estimating the canal length is essential for reaching to a proper endodontic treatment. Any error and miscalculation in estimation of the working length, especially in curved canals, can result in complication during and after root canal therapy. The introduction of digital radiography has enabled us to measure curved canal length. The purpose of this study was to evaluate the calibration tool of Complementary Metal Oxide Semiconductor (CMOS) digital system in estimation of working length.
Materials and Methods: In this in-vitro study, 80 extracted molar teeth were selected and randomly divided into three groups based on angle and radius of canal curvature. A 5 mm orthodontic wire was placed on the lateral surface of the root. Conventional radiographs were taken after insertion of endodontic file in the apical third of root canals. Radiographic images were scanned and imported to the software of CMOS digital system. Two observers estimated the file lengths with and without using calibration tool of digital measurement software. The correlation between observers was evaluated and then data were analyzed using Paired T-test with 95% confidence.
Results: Overall agreement between observers was good. There was no significant difference between the mean values of calibrated measurement and true file length in the basis of canal curves (P>0.001). However, there was significant difference between the mean values of uncalibrated measurement and true file length in the basis of canal curvature (P<0.001).
Conclusion: The calibrated measurement of file length was more accurate than that of the uncalibrated file length measurement.
Ehsan Tavakoli Hosseini, Abdolrahim Davari, Mahsa Asemi Esfahani,
Volume 30, Issue 3 (10-2017)
Abstract
Background and Aims: Radiopacity is an essential requirement for all restorative materials. Radiopaque materials allow the dentist to diagnose and assess radiographically the restoration, primary caries, assessment of contours, overhang and secondary caries. The aim of this study was to evaluate the radiopacity of two types of dental bases and liners in comparison whit dental structure using a digital radiography system.
Materials and Methods: Two classes of materials were prepared: 1 mm and 2 mm thickness disks for glass inomer and 1 mm and 0.5 mm thicknesses for dycal. Specimens of enamel and dentine with the same thicknesses were obtained. As a control, an aluminum step wedge was used. Samples were positioned over a phosphor-ray, plate of min ray soredex system, exposed, and the images were analyzed using the contour dent software. ANOVA analysis was used to investigate the significance of differences among the groups. For pairwise comparisons, the Bonferroni test was applied (P<0.005).
Results: 0.5 mm diameter of self-cure and light cure dycal and enamel, presented radio-opacity higher than that of dentine, except for the light cure dycal that had radiopacity lowers than enamel. 1 mm diameter of all the groups presented higher radiopacity than dentin. Light cure and self-cure glass inomer and self-cure dycal presented radiopacity higher than enamel. Enamel showed radipacity higher than light cure dycal in 2 mm diameter self-cure. Light cure glass inomer presented radiopacity higher than that of enamel and dentin.
Conclusion: The increased thickness of the materials evaluated increased their radio-opacity. It was concluded that all the materials had lower radiopaaty than dentin. Only enamel showed higher radiopacity than light-cured dycal.
Farzaneh Mosavat, Hoorieh Bashizadeh Fakhar, Mohammad Javad Kharrazi Fard, Fatemeh Malekpour Estalaki,
Volume 32, Issue 2 (10-2019)
Abstract
Background and Aims: Accurate diagnosis of vertical root fracture (VRF) is a fundamental importance in endodontics. Because of poor prognosis of VRF, digital radiographs with two horizontal angles have limitations in VRF detection. Also, Gutta-percha can produce artifacts that impair CBCT scan accuracy. The aim of this study was to compare accuracy of CBCT and digital radiography system in vertical root fracture in endodentically treated teeth.
Materials and Methods: In this study, 60 endodentically treated single teeth were selected and randomly coded. The teeth were divided into two groups: 30 with induced root fracture and 30 with no fracture. CBCT scan and digital radiographs with two horizontal angles with a difference of fifteen degrees for all teeth were performed. Two observers assessed the CBCT images and digital radiographies for presence of VRF. The statistical analysis used in this study was Weighted Kappa.
Results: CBCT had the highest sensivity (75.8) and specificity (90). Digital radiography with 68.3 sensitivity and 79.1 specificity were not as efficient as CBCT (P<0.05).
Conclusion: According to this study, the accuracy of CBCT seems to be higher than that of digital radiography in detecting VRF and provides the most reliable data in comparison of digital radiography.
Amineh Ghaznavy, Ahmad Reza Talaeipour, Mehdi Vatanpour, Amir Abbas Moshari,
Volume 33, Issue 4 (1-2021)
Abstract
Background and Aims: Pulpal exposures originated from the external cervical root resorptions have major effects on the treatment and prognosis. Therefore, the aim of this study was performed to compare the two different imaging systems-digital radiography with PSP (Photostimulable Phosphor) sensor in three horizontal different views and CBCT (cone beam computed tomography) images to assess the pulpal exposure in simulated cavity of external cervical root resorptions that was performed in 1398 in the School of Dentistry of Azad University.
Materials and Methods: 40 intact maxilla anterior teeth with straight roots were included. Teeth were randomly divided to two groups (20 teeth with and 20 without pulpal exposures). Each sample was assessed using PSP digital radiography (in 3 horizontal angles) and CBCT image system, to detect the presence of pulpal exposures. False negative and false positive results in 2 imaging procedures were judged with ratio test.
Results: The results showed in CBCT (P.P.V=85.7%) and (N.P.V=89.5%), and in digital intraoral radiography (P.P.V=80%) and (N.P.V=80%) in proximal defects. Ratio test showed that there were no significant differences in the proximal defects (P<0.4).
Conclusion: The results showed that there were no significant differences in detection of exposure in the proximal surfaces between two imaging systems.