Search published articles


Showing 3 results for Dimensional Change

Sm. Sahebi, Sh. Rocni ,
Volume 17, Issue 2 (6-2004)
Abstract

Statement of Problem: Different temperature and moisture around Iran and wide usage of stone type IV in dental laboratories in our country were the reasons for us for doing this study.

Purpose: In this survey the effect of temperature, moisture and time on dimensional change of dental stone type IV (Velmix) were investigated.

Materials and Methods: In this experimental study cube shape Metal models (10×10×10mm) was made for Taking impression. We used special tray, which has ten holes (15×20×25mm) and made impression with condensational silicone in two-step procedure, and poured it with stone type IV. stone cubes were divided to different groups. 3 groups holed in fix moisture and variable tempraure and 5 groups in fix temperature and variable moisture. After 2 hours, 24 hours and one-week dimension of stone cubes were measured. Then analysis was done with ANOVA and dauncan.

Results: The following conclusions were achieved: 1-Time has no effect on dimensional changes. 2-Tempreture and moisture has some effect on dimensional changes in stone IV. Increasing of temperature result in stone contraction and increasing in moisture result in stone expansion.

Conclusion: The best temperature for least dimensional change is 20C and the best moisture for a least dimensional change is 30 %.


S. Nokar , R. Baghaee-Naeeni ,
Volume 17, Issue 3 (8-2004)
Abstract

Statement of Problem: In the treatment of edentulous patients with implant supported fixed partial dentures several factors such as implant numbers, implant position, superstructure pattern and cantilever length must be considered. Mandibular flexture in function exerts forces in peri-implant bone, however this phenomenon has received little attention.

Purpose: The goal of this finite element analysis (FEA) study was to evaluate the effect of mandibular dimensional changes on peri-implant bone stress in different prosthesis and implant treatment plans.

Materials and Methods: In this experimental study, three dimensional finite element computer model of mandible was simulated according to data from CT-Scan in 0.5 mm sections. The model of 4.110 mm ITI implant, measured by profile projector, was simulated in solid works 2003 software. Implant models were inserted, in two different patterns, on mandible and three different superstructures were placed on implants. Two clenching tasks were modeled (incisal clench and right molar clench).

Results: Analysis of Von Misses stress for peri-implant bone revealed the lowest stress values in three-piece superstructure.

Conclusion: According to this study, additional placement of implants in order to fabricate independent prostheses and to achieve the freedom of mandibular flexture are recommended.


Somayeh Hekmatfar, Sahar Mousavi, Hamed Mohammadian, Karim Jafari,
Volume 32, Issue 2 (10-2019)
Abstract


Background and Aims: Gypsum products are used for several different purposes. Adaptation and success of casting restorations are dependent on dimensional accuracy, strength, and reproduction of details of dental gypsums. This study was designed to evaluate the dimensional changes and accurate details reproduction of three type IV dental gypsums.
Materials and Methods: 60 samples in 3 groups of dental gypsums of G30,Yeti Rock and FujirockEP were evaluated. The detail reproduction of 50 micron scratched line was analyzed by a microscope at 12× magnification. The samples were assayed for dimensional changes at 2 and 24 hours and 1 week after pouring. Photograph images were taken from samples in fixed distance by a camera (Canon D600) and analyzed in corel draw software. Data were analyzed using ANOVA and chi-square (P<0.05).
Results: There were significant differences in the details reproduction between three gypsums (P≤0.05) and the highest values was for Fujirock EP, Yeti Rock. The G30 did not reconstruct the details. There was no significant difference in the dimensional changes of the evaluated gypsums based on time (P≥0.05).
Conclusion: All three different gypsums evaluated in this study showed the dimensional stability during one week. Fujirock EP and Yeti Rock could reconstruct the details and G30 gypsum could not.


Page 1 from 1     

© 2026 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb