Search published articles


Showing 5 results for File

Ms. Sheykhrezaee , N. Eshghyar , B. Farzaneh , K. Ashofteh Yazdi ,
Volume 17, Issue 3 (8-2004)
Abstract

Statement of Problem: Total removal of tissues and remnant microorganisms as well as canal shaping are the essential objectives of endodontic therapy. A successful endodontic treatment is obtained through Shilder’s principals, however complete observation of this technique using stainless steel files manually is problematic and time-consuming. Modern technology, in order to eliminate such problems, has presented new facilities such as Nickel-Titanium (NiTi) files and engine driven instruments.

Purpose: The aim of this in-vitro study was to compare the canal debridement efficiency of three engine driven instruments: Rotary, Reciprocal and Vertical.

Materials and Methods: In this experimental study, 60 mesial roots of human first and second mandibular molars were divided into three groups randomly. In each sample, one canal was considered as case, the other one as control. Files used in Reciprocal and vertical groups were of handy Ni-Ti type and in rotary group, rotary Ni-Ti files were used. After debridement, the roots were sectioned at 3mm and 5mm from anatomic apex, stained and examined under light microscope. Comparison criteria between case and control groups were based on residual debris and predentin and the level of root canal preparation and shaping after debridement. Data were subjected to kruskal-Wallis non-parametric test.

Results: There was no significant difference between the efficiency of debridement at 3mm and 5mm sections between all groups. But difference in time consumption was significant ranked from the shortest to the longest as rotary, reciprocal and vertical.

Conclusion: The efficiency of debridement between the three automated instruments was approximately equal, however the instrumentation time was different between three groups. Rotary system was the fastest one, as compared with reciprocal (second) and vertical (last). It may be concluded that rotary system has a superiority over the other two groups in conventional root canal therapies.


M. Zarrabian , M. Aligholi , N. Loghmani Nejad ,
Volume 18, Issue 2 (5-2005)
Abstract

Statement of Problem: Root canal cleaning and elimination of the source of infection are the most important basis and the main requirements for successful root treatment since the main cause of failure in root treatment is the permeation of bacteria or their products into the periapical tissues. Nowadays, the newly designed and prcsented instruments for canal instrumentation can improve root treatment.

Purpose: The aim of this study was to compare the decrease in the number of intracanal Enterococcus-faecalis (Ef) among three mechanical instrumentation methods: manual (K-type) and rotary (Race, Profile).

Materials and Methods: In this experimental study, 30 single rooted teeth were selected. Three cases were considered as negative and three cases as posetive controls and 24 remainder cases were divided into three experimental groups. All root canals were inoculated by Ef and samples were taken from all canals to prepare microbial cultures. The three instrumentation procedures were: - Crown- down technique with K-type manual system file - Crown- down technique with Profile rotary system - Crown- down technique wiht Race rotary system After instrumentation, microbial cultures were taken from root canals and the reduction rate of bacteria were evaluated and compared using one way ANOVA test with P<0.05 as the limit of significance.

Results: There was no significant difference among the three instrumentation procedures regarding bacterial elimination.

Conclusion: According to the finding of this study, K-type manual file, Profile and Race rotary systems, all can be used in canal instrumentaion. However, since manual files are more accessible and require less equipment compared with rotary systems, and since the ability of all of these methods is identical regarding bacterial elimination, manual files can be used in straight canal instead of rotary systems.


M. Tabrizizadeh , N. Nekoofar ,
Volume 18, Issue 4 (1-2006)
Abstract

Background and Aim: Maintaining the original canal path and safety of canal preparation during instrumentation in curved canals have been subjected to many challenges. The aim of this study was to compare several parameters of root canal preparation using flexmaster rotary and hand used Nickel-Titanium instruments.

Materials and Methods: In this experimental study, sixty extracted human teeth with root canal curvatures between 10 and 42 degress were devided into two similar groups with equal mean curvatures. Root canals in one group were prepared using flexmaster rotary instruments and the other with NiTi hand files.After canal preparation, different parameters such as straightening of curved root canal, loss of working length, fracture rate, perforation and working time, were evaluated and compared between the two groups. Data were analyzed by t student test with p<0.05 as the limit of significance.

Results: Results showed that both instruments maintained the original canals' curvature. No loss of working length, instruments fracture or perforation was recorded. Working time was significantly shorter for flexmaster than hand files.

Conclusion: Both systems under investigation respected original root canal curvature and were safe to use. Therefore the rotary techniques could be successfully introduced to undergraduate endodontic programmes.


S. Khedmat , M. Vahdatifar ,
Volume 19, Issue 2 (5-2006)
Abstract

Background and Aim: Recent advances in technology have permitted manufacturers to produce endodontic files from NiTi alloy and rotary systems. According to manufacturers, these files maintain original canal shape better than hand files and reduce treatment time. The aim of this study was to compare a new rotary system (Race) with an older one (Profile) in maintaining the original shape of curved canal and the working length as well as the procedural accidents rate.

Materials and Methods: In this experimental study, 40 polyester blocks with curved canals (45 ), were fabricated and divided into 2 groups. After primary working length determination and staining with methylene blue, photographs were taken. Canal preparation was done with Profile and Race rotary systems according to manufacturers and working length was measured again. Canal staining by eosin was performed and photographs were taken for the second time. The two images were superimposed and changes in canals anatomy in 5 sections were recorded. Data were analyzed by t test with p<0.05 as the limit of significance.

Results: There was no significant difference in inner and outer canal walls transportation between 2 groups (P> 0.05). Changes in working lengths and procedural accidents were similar in the studied groups (P> 0.05).

Conclusion: Based on the results of this study, changes in canal anatomy and working length of simulated severely curved canals as well as procedural accidents rate are similar in two rotary systems and both are suitable for canal preparation.


Mohammad Javad Etesami, Seyyed Lotfollah Derakhshan, Kiomars Nazari Moghadam, Mohammad Ebrahimi Saravi,
Volume 29, Issue 1 (7-2016)
Abstract

Background and Aims: Cleaning and shaping is one of the most important stages in endodontic treatment. Single-file systems save time and reduce the risk of transmission of pathogens. This in vitro study was aimed to compare the rate of canal transportation after the preparation of the stimulated resin root canal with two single-file systems, namely Waveone and Reciproc.

Materials and Methods: Thirty stimulated resin root canal blocks with size 8/0. 02 K file were randomly divided into two study groups. The preparation in Group A and Group B was performed using Reciproc and Waveone files, respectively. Pre and post- preparation photographs were taken and the images were superimposed to evaluate the inner and outer wall’s curvature tendency at three points (apical, middle and coronal) using AutoCad pragram. Data were analyzed using T-test.

Results: Based on the results, the degree of transportation in the inner and outer walls of the canal was less at the level of 3 millimeters (P<0.001) and there was no significant difference between the two groups regarding the deviation at the levels of 1 and 5 millimeters (P>0.05).

Conclusion: Waveone showed better performance in the middle third of canal and this system maybe recommended.



Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb