Search published articles


Showing 2 results for Fracture Toughness

T. Hooshmand , A. Keshvad , K. Moharamzadeh ,
Volume 17, Issue 2 (6-2004)
Abstract

Statement of Problem: In a previous study it was reported that a durable resin-ceramic tensile bond could be obtained by an appropriate silane application without the need for HF acid etching the ceramic surface. Evaluation of the appropriate application of silane by other test methods seems to be necessary.

Purpose: The purpose of this study was to compare the interfacial fracture toughness of smooth and roughened ceramic surfaces bonded with a luting resin.

Materials and Methods: Ceramic discs of 10 mm in diameter and 2 mm in thickness were prepared. Four different surface preparations (n=10) were carried out consisting of (1) ceramic surface polished to a 1µm finish, (2) gritblasted with 50µm alumina, (3) etched with 10% HF for 2 min, and (4) gritblasted and etched. The ceramic discs were then embedded in PMMA resin. For the adhesive area, the discs were masked with Teflon tapes. A circular hole with diameter of 3 mm and chevron-shaped with a 90° angle was punched into a piece of Teflon tape. The exposed ceramic surfaces were treated by an optimised silane treatment followed by an unfilled resin and then a luting resin cylinder of 4mm in diameter and 11 mm in length was built. Specimens were stored in two different storage

conditions: (A): Distilled water at 37°C for 24 hours and (B): Distilled water at 37°C for 30 days. The interfacial fracture toughness (GIC) was measured at a cross-head speed of 1 mm/min. The mode of failure was examined under a stereo-zoom microscope and fracture surfaces were examined under Scanning Electron Microscope.

Results: The mean interfacial fracture toughness values were Group A: 1) 317.1±114.8, 2) 304.5±109.2, 3) 364.5±169.8, and 4) 379.4±127.8 J/m2±SD. Group B: 1) 255.6±134.4, 2) 648.0±185.1, 3) 629.3±182.6 and 4) 639.9 ±489.0 J/m2±SD. One way Analysis of Variance showed that there was no statistically significant difference in the mean interfacial fracture toughness for groups A1-A4 (P>0.05). However, the mean interfacial fracture toughness for group B1 was significantly different from that for groups B2, B3 and B4 (P<0.05). Independent-ٍٍٍSamples T-Test results showed that there was a significant increase in the GIC mean value for groups B2 and B3 after 30 days water storage (P<0.05). The modes of failure were predominantly interfacial or cohesive within the resin. Conclusions: The fracture toughness test method used in this study would be appropriate for analysis of the adhesive zone of resin-ceramic systems. From the results, it can be concluded that micro-mechanical retention by gritblasting the ceramic surfaces could be sufficient with no need for HF acid etching the ceramic surfaces when an appropriate silane application procedure is used.


Seyyede Fateme Basri, Rafat Bagheri, Maryam Sadat Tavangar,
Volume 31, Issue 1 (6-2018)
Abstract

Background and Aims: Fracture and color change are among the most common causes of clinical failure of resin composite restorations. Therefore, this study aimed to examine the fracture toughness and color changes of 3 Nano-hybrid resin composites in dry and wet conditions.
Materials and Methods: Three resin composites were studied. A total of 36 rectangular specimens were prepared for each material, randomly divided into 2 groups, and stored at 37°C dry or soaked in distilled water. In each group, the specimens were subdivided into three groups (n=6) and stored for 1, 7, and 60 days. After each time interval, the specimens were tested for the fracture toughness and loaded at a cross-head speed of 0.5mm/min using a universal testing machine. The baseline and final color measurement was recorded for each specimen using a spectrophotometer. The collected data was analyzed using ANOVA and Kruskal-Wallis tests.
Results: After 60 days, the mean value of fracture toughness was lower in the wet condition compared to that of dry condition. However, it was not significantly different except for aura Bulkfil (P=0.001). Color change was significantly different for Tetric Evoceram and aura with a greater value in the wet condition compared to that of dry (P=0.004). The greatest color stability was found for aura and the least for Tetric Evoceram.
Conclusion: In this study, most of the materials stored in a dry condition showed a greater fracture toughness and color change.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb