Search published articles


Showing 4 results for Gap

M. Ghavam-Nasiri , F. Malek-Nejad , A. Rohani , M. Akbari ,
Volume 16, Issue 2 (5-2003)
Abstract

Statement of Problem: A lot of efforts have been made to create a complete adaptation between tooth and amalgam restorations.
Purpose: The aim of this study was to evaluate microleakage and interfacial micromorphology of amalgam restorations lined with dentin adhesives, namely One Coat Bond, Syntac, Excite and Copalite,as liners.
Materials and Methods: 144 intact human canine teeth were selected. Then class V cavities, with enamel and dentinal margins, were prepared on each of them. Cavities were lined with different dentin bonding systems (Syntac, One Coat Bond and Excite) according to the manufacturer's instructions and restored with Oralloy and Cinalloy, non gamma 2 spherical amalgams and Aristaloy a non gamma 2 Admixed alloy. Copalite was used in the group, served as controls. After thirty days storage in synthetic saliva at 37°c, the specimens were thermocycled in saliva (4000 cycles). The degree of microleakage was assessed by means of basic fushin dye penetration and recorded. The gap width was evaluated with Scanning Electron Microscope. Pearson and %2 tests were used to analyze the results.
Results: None of the systems, tested in this study, eliminated microleakage completely, Pearson's correlation coefficient showed a positive correlation between gap and microleakage (P<0/05).Statistical significant differences were revealed among the liners regarding gap and microleakage (P<0.05).One Coat Bond and Syntac appeared to leak less than other groups. The gap width by One Coat Bond and Syntac were respectively 0.35 and 0.3 urn in dentine, 0.2 and 0.1 in enamel. Excite and copalite gap width in dentine and enamel were 1,3-1.36 urn and 0.3-0.6, respectively. The type of amalgam did not have any effect in the degree of microleakage and gap width (P>0/05).
Conclusion: One Coat Bond and Syntac, comparing to Excite and Copalite, showed less microleakage and gap width.
H. Siadat, A. Mirfazaelian , M. Alikhasi , M. Mohammad Alizadeh ,
Volume 20, Issue 4 (1-2008)
Abstract

Background and Aim: An important criterion for success assessment of implant-supported prostheses is marginal fit. Vertical and horizontal discrepancy can result in loosening of the prosthetic screw, crestal bone resorption, peri-implantitis and loss of osseointegration. Despite careful attention to waxing, investing, and casting, marginal discrepancies are inevitable. The aim of this study was to evaluate the marginal gap and overhang in three casting methods with two different alloys in ITI implants.

Materials and Methods: In this experimental in vitro study 48 analog abutments were randomly divided into six groups as follows: 1) burn out cap + BegoStar, 2) impression cap + BegoStar, 3) conventional wax up + BegoStar, 4) burn out cap + Verabond2, 5) impression cap + Verabond2, 6) conventional wax up + Verabond2. Waxing was done in 0.7 mm thickness verified by a digital gauge and a putty index was made for all groups. Reamer was used for correction of the finish line after casting in all groups. Castings were seated on analog abutments and embedded in acrylic resin. Specimens were sectioned by isomet instrument and polished and cleaned by ultrasonic cleaner for 10 min. The marginal gap and overextended margins of castings were examined under a  Scanning Electron Microscope (SEM) (X200). The mean gap and margin overextension were calculated for each group. Data were analyzed by multivariate analysis and Bonferroni post-hoc test with p<0.05 as the level of significance.

Results: No significant difference in gap size was observed among the three casting methods with two alloys (P=0.056). The marginal gap was not different in the studied casting methods (P=0.092). Gold alloy crowns showed lower marginal gaps compared to base metal alloy crowns (P<0.001). No significant difference in overhang size was observed among casting methods with two alloys (P=0.093). Base metal alloy crowns showed less overhang compared to gold alloy crowns (P<0.001). There was a significant correlation between overhang and use of impression cap in base metal alloys (P<0.001).

Conclusion: Based on the results of this study, vertical discrepancy of frameworks made with gold alloy were less than those made with base metal alloy. Base metal alloy demonstrated less overhang. Conventional wax up or using burn out caps produced less horizontal discrepancy.


Majid Sahebi, Marzieh Alikhasi, Farshad Movafegh, Vahideh Nazari,
Volume 29, Issue 1 (7-2016)
Abstract

Background and Aims: In response to esthetic demand and use of zirconia abutments; detection of implant-abutment connection misfit is so important. The purpose of this study was to evaluate the sensitivity and specificity of radiographic images in the detection of abutment-implant connection misfit in zirconia and titanium abutments of three different implant connections.

Materials and Methods: One regular implant fixture of Branemark, Noble active and Replace systems were mount in acrylic models. Two pieces titanium and zirconium abutments were attached to the implants, once with correct adaptation and once with 0.5 mm spacer. Digital radiographic images were taken of 12 created states with zero degree vertical and horizontal inclination and evaluated by 10 specialists in implant treatment in two different time penods. Data were analyzed using Kappa analysis.

Results: Interclass Correlation Coefficients (ICC) of the agreement of answers in the first and second times were 97.4 and 97.5, respectively (P<0/001). Sensitivity of detecting gap in all groups was acceptable (95-100%) except titanium abutment in Noble active which was the lowest value (35%). Specificity of all groups were acceptable (80-95%) except zirconia abutments in Noble active and Replace with 45% and 30% values, respectively, and titanium abutments in Branemark had the highest value (95%).

Conclusion: The sensitivity of radiographic images in detection of abutment-implant connection misfit only in Noble active with titanium abutment was not acceptable. Specificity of radiographic images in the absence of gap in titanium abutments was more favorable.


Gholamreza Esfahanizadeh, Mahmood Aghel, Saeed Mohammadi Asl, Elnaz Bayat,
Volume 30, Issue 4 (1-2018)
Abstract

Background and Aims: Marginal gap measurement in all ceramic restorations they are of fundamental important for the successful used. As some studies led to contradiction results, yhe aim of this study is to compare marginal gap restorations between 4 kinds of ceramic restorations Inceram, IPS-e.max Press, Zirconia (CAD/CAM) and PFM.
Materials and Methods: In this In-vitro experimental research, one stainless steel die with deep chamfer finish line design (1 mm depth) was prepared on a maxillary premolar. 40 epoxy resin dies were made, dies were divided in to 4 groups (n=10), Zirconia, IPS e.max press, Inceram, Mental Ceramic systems (MC). Then, the prepared crowns were put on the stainless steel die and observed their marginal mismatch under sterio microscope before cementation. Data were analyzed by One- way ANOVA, and one sample kolmogorosmirnov tests.
Resultes: There was significant difference in the marginal gaps between (MC) (102.92±28.7), Inceram (98.41±24.91), IPS e.max press (128.22±25.48), and Zirconia (69.5±10.9) (P=0.0001).
Conclusion: The comparison of marginal gap for the four groups was significant test. Therefore, it can be concluded that marginal gap, the probability of leakage and recurrence of caries in Zirconia systems is the least and in the IPS e.max press systems is the most.


Page 1 from 1     

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb