Search published articles


Showing 6 results for Polish

Sh. Kasraie , Mj. Assary , Hr. Abdosamadi , Kh. Mani Kashani , S. Arabzadeh ,
Volume 20, Issue 4 (1-2008)
Abstract

Background and Aim: Nowadays, esthetic dentistry has become an important part of modern dentistry. Bleaching is considered as a conservative, safe and effective way for treatment of discolored teeth. Although bleaching is commonly used on anterior teeth, the bleaching gel may come into contact with patient's former amalgam restorations and result in corrosive effects, dissolution of amalgam phases and increasing release of mercury. Mercury released from dental amalgam during mouthguard bleaching can be absorbed and increase the total mercury body burden. The aim of this study was to determine the amount of mercury released from Iranian and foreign brands of amalgams with spherical and admixed particles, polished and unpolished, after 16%carbamide peroxide gel application.

Materials and Methods: This experimental in vitro study was performed on 256 Iranian and foreign amalgam samples with spherical and admixed particles. The provided samples were put in distilled water and classified according to the type of amalgam, shape of particles and quality of surface polishing. The test samples were placed in Nite White 16% carbamid peroxide gel and control samples were put in phosphate buffer (Ph=6.5) for 14 and 28 hours. The amount of released mercury was calculated using AVA-440 Mercury Analysis System (Thermo Jarrell Ash model SH/229) with cold-vapor atomic absorption. Data were analyzed using t-test, four way and three way ANOVA tests with P<0.05 as the level of significance.

Results: 16% Nite White carbamide peroxide gel caused a significant increase in amount of mercury released from amalgams in all groups (P<0.05). Mercury release from Iranian amalgam was higher than that from the foreign brands (P<0.05). There was no significant difference in mercury released from spherical and admixed amalgams (P>0.05). The amount of mercury released from Iranian and foreign amalgams was time dependent (P<0.05). Furthermore, the amount of mercury released from unpolished amalgams was higher than polished ones (P<0.05).

Conclusion: The present study indicated that exposure of amalgam to 16% Nite White carbamide peroxide  gel causes a significant increase in mercury release from the amalgam which is significantly influenced by the brand, exposure time, and surface polishing.


E. Yasini, H. Kermanshah, M. Mirzaie, B. Ranjbar Omidi,
Volume 24, Issue 3 (6-2011)
Abstract

Background and Aims: Marginal seal in class V cavities and determining the best restorative material to decrease microleakage is of great importance in operative dentistry. The aim of this study was to evaluate the effect of polishing time on the microleakage of three types of tooth-colored restorative materials in class V cavity preparations and to assess the marginal integrity of these materials using scanning electron microscope (SEM).
Materials and Methods: In this in vitro study, class V cavity preparations were made on the buccal and lingual surfaces of 30 bovine incisors (60 cavities). The specimens were divided into three groups each containing 10 teeth (20 cavities): group 1, Filtek Z350 (nanocomposite) group 2, Fuji IX/G Coat Plus (CGIC) and group 3, Fuji II LC (RMGI). In each group, half of the specimens (n = 20) were finished/polished immediately and the rest of them were finished/polished after 24 hours. All the specimens were thermocycled for 2000 cycles (5-50 °C). Epoxy resin replicas of 12 specimens (2 restorations in each subgroup) were evaluated using SEM and the interfacial gaps were measured. Finally, the teeth were immersed in 0.5% basic fuchsin dye for 24 hours at room temperature, sectioned and observed under stereomicroscope. The data were analyzed using Kruskal-Wallis and Mann-Whitney U tests and the comparison between incisal and cervical microleakage was made with Wilcoxon test.
Results: Incisal and cervical microleakage were not affected by polishing time in none of the three restorative materials (P>0.05). Cervical microleakage only in Fuji IX with immediate polishing was significantly higher than incisal microleakage (P<0.05). Incisal and cervical microleakage with immediate or delayed polishing were not significantly different in Fuji IX, Fuji II LC, and Z350 (P>0.05).
Conclusion: Immediate polishing is recommended in tooth-colored class V restorations.


Masumeh Hasani Tabatabaei, Sakine Arami, Ayob Pahlavan, Esmaeil Yasini, Mansoure Mirzae, Hamid Kermanshah, Farnaz Farahat,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: To evaluate the effect of polishing on surface roughness of silorane-based composite using profilometery and Scanning Election Microscopy (SEM) and compare it with that of a methylmethacrylate-based composite and a glass ionomer.

Materials and Methods: In this study, 3 groups (n=28) were tested: specimens of two composites (Filtek P90 and Filtek P60) and a glass ionomer (Fuji IX) which were prepared in polyethylene molds (4 mm diameter×10 mm height). Half of the specimens in each group were finished with 180-grit silicon carbide paper and the remaining were finished with 180-grit, and subsequently polished with 250, 400, 800, 1000, 2000, and 2500-grit silicon carbide papers. The surface roughness was evaluated using a contact profilometer and then mean (Ra) and maximum (Rmax) of surface roughness were recorded. Then, the surface of 4 specimens of each subgroup was observed under SEM. Statistical analysis was performed with T-test, ANOVA and Dunnett T3 tests.

Results: In all materials, Ra was different between polishing with 180 and 2500-grit silicon carbide papers. In 180-grit group, only Ra of Filtek P60 and Fuji IX showed significant difference (P=0.01). In 2500-grit group, there was no significant difference between the Ra of Filtek P60 and Filtek P90 (P=0.56).

Conclusion: Polishing is recommended for the glass ionomer and posterior composite restorations.


Ayob Pahlevan, Tabassom Hooshmand, Mansoreh Mirzaie, Hoda Safaie,
Volume 26, Issue 1 (3-2013)
Abstract

Background and Aims: The purpose of this in vitro study was to assess the effect of two different surface treatments on the contrast ratio of IPS e.max press ceramic submitted to accelerated aging.

Materials and Methods: Ten ceramic (IPS e.max Press) disks (10-mm diameter and 1.5-mm thick) were fabricated according to the manufacturer's recommendations. The samples were randomly divided into 2 groups (n=5): polishing and glazing. Contrast ratio ware obtained with a spectrophotometer before and after accelerated aging. The contrast ratio (CR=Yb/Yw), was defined as the ratio of illuminance (Y) of the test material when it is placed on the black background (Yb) to the illuminance of the same material when it is placed over a white background (Yw), was determined. The data were statistically analyzed by two-way analysis of variance (P<0.05).

Results: All specimens of IPS e.max press ceramic showed significant increase in CR after 300-hour accelerated aging time (P=0.005). Polished samples showed significantly higher opacity compared with that of the glazed ones (P=0.018).

Conclusion: Within the limitations of this study, it may be concluded that the glazed specimens showed higher stability in their translucency than the polished specimens.


Fatemeh Kazemi Bidhendi, Mahshid Mohammadi Basir, Doctor Mohammad Bagher Rezvani, Doctor Ali Khodabakhsh, Hossein Labbaf, Mohammad Amin Fahimi,
Volume 35, Issue 0 (5-2022)
Abstract

Background and Aims: Finishing and polishing of composites is a critical step influencing the clinical service of restorations. The aim of this article was to evaluate and compare the effect of two liquid polishes on the polish retention of two nanocomposites.
Materials and Methods: Eighty standardized disk-shaped specimens (4×2 mm) were prepared from two nanocomposites (n=40), including one nano-filled composite (Filtek Z350 XT-3M ESPE, USA) and one nano-hybrid composite (Aelite Aesthetic Enamel-Bisco, Inc. Schaumburg, USA). The specimens were randomly divided into 4 subgroups (n=10) based on the method of finishing (F) and polishing (P) procedures: M: as control, polymerized under Mylar strip; S: finish and polish with a sequence of Sof-Lex discs (3M ESPE, USA); SP: finish and polish with Sof-Lex discs and use of Permaseal liquid polish (Ultradent products, Inc. USA); SB: finish and polish with Sof-Lex discs and use of Biscover liquid polish (Bisco, Inc. Schaumburg, USA). The specimens were undergone pH cycling and brushing machine and then, the average surface roughness (Ra) and average profile changes along the desired area (Rz) of the specimens were determined with profilometer instrument. Two-way and one-way analysis of variance (ANOVA) was used to compare the mean of surface roughness. Then, Tukey test was used to identify the groups responsible for the difference and t-test was used to compare the mean of surface roughness.
Results: The type of composite and the method of polishing procedure had no effect on the mean Ra (P=0.733) but it had significant effect on Rz1 factor (P=0.025).
Conclusion: Using liquid polish after polishing discs had no effect on the polish retention of nanocomposites.

Abdolrahim Davari, Farnaz Farahat, Marjan Mehravaran, Alimohammad Doosthosseini, Negar Etminan,
Volume 38, Issue 0 (4-2025)
Abstract

Background and Aims: Finding an appropriate method for polishing that can be used in dental practices to improve the longevity and ease of dental restorations is of great importance. The aim of this study was to evaluate the effect of different polishing methods on the surface roughness of two types of nano-hybrid composites, an in vitro study.
Materials and Methods: In this study, 42 samples in the form of discs (6 mm in diameter and 3 mm in thickness) of two nano-hybrid composites (Charisma Kulzer and EvoCeram Tetric IPS) were prepared. Each group had 21 samples (polymerized in a mold made of polyfluorohalide material) and were all shaded (A2 color). To prevent mirror-like reflections, each sample was covered. A 2 kg load was applied for 30 seconds on each sample, after which the composites were removed. The samples were stored for 7 days in deionized water at room temperature and in the dark. After this period, the samples underwent finishing and polishing procedures. Seven random samples from each composite group were polished using different methods: System Gloss Composite LUCIDA, EVE polishing discs, and EVE polishing discs + Cosmedent polish. The surface roughness was measured using a profilometer, and observations were made under a microscope. Data were analyzed using SPSS 25 software with t-tests, ANOVA, and the Bonferroni post hoc test.
Results: The two-stage method using EVE polishing discs showed significantly the lowest surface roughness in both types of composites (P<0.0001). The type of composite did not have a significant effect on initial surface roughness (P=0.067), but the polishing method had a significant effect on the surface roughness (P<0.0001). The difference in the mean surface roughness was statistically significant among different polishing methods for either type of composites (P<0.0001). The t-test analysis showed no significant difference in the surface roughness between the two types of composites with different polishing methods (P>0.05), except in the LUCIDA polishing system where a significant difference was observed in both groups.
Conclusion: The results showed that the polishing method had a significant effect on the surface roughness and not the type of composte. The use of EVE polishing discs effectively reduced the surface roughness in both types of nano-hybrid composites used in the present study.


Page 1 from 1     

© 2026 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb