M. Zarrabian , M. Aligholi , N. Loghmani Nejad ,
Volume 18, Issue 2 (5-2005)
Abstract

Statement of Problem: Root canal cleaning and elimination of the source of infection are the most important basis and the main requirements for successful root treatment since the main cause of failure in root treatment is the permeation of bacteria or their products into the periapical tissues. Nowadays, the newly designed and prcsented instruments for canal instrumentation can improve root treatment.

Purpose: The aim of this study was to compare the decrease in the number of intracanal Enterococcus-faecalis (Ef) among three mechanical instrumentation methods: manual (K-type) and rotary (Race, Profile).

Materials and Methods: In this experimental study, 30 single rooted teeth were selected. Three cases were considered as negative and three cases as posetive controls and 24 remainder cases were divided into three experimental groups. All root canals were inoculated by Ef and samples were taken from all canals to prepare microbial cultures. The three instrumentation procedures were: - Crown- down technique with K-type manual system file - Crown- down technique with Profile rotary system - Crown- down technique wiht Race rotary system After instrumentation, microbial cultures were taken from root canals and the reduction rate of bacteria were evaluated and compared using one way ANOVA test with P<0.05 as the limit of significance.

Results: There was no significant difference among the three instrumentation procedures regarding bacterial elimination.

Conclusion: According to the finding of this study, K-type manual file, Profile and Race rotary systems, all can be used in canal instrumentaion. However, since manual files are more accessible and require less equipment compared with rotary systems, and since the ability of all of these methods is identical regarding bacterial elimination, manual files can be used in straight canal instead of rotary systems.


S. Khedmat , M. Vahdatifar ,
Volume 19, Issue 2 (5-2006)
Abstract

Background and Aim: Recent advances in technology have permitted manufacturers to produce endodontic files from NiTi alloy and rotary systems. According to manufacturers, these files maintain original canal shape better than hand files and reduce treatment time. The aim of this study was to compare a new rotary system (Race) with an older one (Profile) in maintaining the original shape of curved canal and the working length as well as the procedural accidents rate.

Materials and Methods: In this experimental study, 40 polyester blocks with curved canals (45 ), were fabricated and divided into 2 groups. After primary working length determination and staining with methylene blue, photographs were taken. Canal preparation was done with Profile and Race rotary systems according to manufacturers and working length was measured again. Canal staining by eosin was performed and photographs were taken for the second time. The two images were superimposed and changes in canals anatomy in 5 sections were recorded. Data were analyzed by t test with p<0.05 as the limit of significance.

Results: There was no significant difference in inner and outer canal walls transportation between 2 groups (P> 0.05). Changes in working lengths and procedural accidents were similar in the studied groups (P> 0.05).

Conclusion: Based on the results of this study, changes in canal anatomy and working length of simulated severely curved canals as well as procedural accidents rate are similar in two rotary systems and both are suitable for canal preparation.



Page 1 from 1     