Masumeh Hasani Tabatabaei, Sakineh Arami, Fatemeh Khajavi, Zohreh Moradi,
Volume 29, Issue 4 (1-2017)
Abstract

Background and Aims: Despite the reduction of incidence of dental caries in recent years, this disease is common and many efforts were conducted to decrease the prevalence of dental caries. On the other hand secondary caries lesions are the main reason for replacement of direct restorations. Therefore, the aim of the current study was to evaluate suitable methods of preparation and restorative materials to reduce caries recurrence.

Materials and Methods: In this experimental study, eighty human teeth were collected and stored in normal saline. The teeth were soft-tissue debrided and cleaned with water/pumice slurry and rubber cups in a low-speed handpiece. Speciments were randomly divided in two main groups. Cavities were prepared with diamond burs or Er:YAG laser (10 Hz, 300 mJ, 3W). Each group was divided into 4 sub-groups, and restored with a glass-ionomer cement (Fuji IX), resin modified glass-ionomer (Fuji II LC), total etch bonding + composite resin or self-etch bonding + composite resin. The specimens were submitted to pH cycling. Speciments were then sectioned, polished and Vickers microhardness measurements were performed on each specimen. Differences among the medians were analyzed using two way ANOVA test at a 95% confidence level and Tukey test.

Results: Statistical analysis showed significant difference in the type of substrate (enamel, dentin) in both main groups (P<0.0001) but no differences in the caries lesion development between the cavities restored with the same material and prepared with diamond burs or Er:YAG laser.

Conclusion: The Er:YAG laser used for cavity preparation and different types of restorative materials used did not show the ability to guarantee significantly more acid-resistance tooth structure against demineralization.


Hoseinali Mahgoli, Rezvaneh Ghazanfari, Mahdi Mirmohammadi, Davoud Zare, Mahnaz Arshad,
Volume 32, Issue 3 (11-2019)
Abstract

Background and aims: Solubility is an important property of luting cements in determining clinical durability. The aim of this study was to compare the solubility of Panavia, Calibra and Maxcem resin cements with that of GC Fuji PLUS resin modified glass ionomer cement in three different pH values.
Materials and Methods: A total of 96 specimens were prepared (8mm diameter, 4mm thickness) according to manufacturer instructions. After setting, they were desiccated and weighed. The specimens were kept immersed in distilled water and lactic acid solution (pH values of 3 and 5) for 30 days and then removed and weighed again. Data were statistically analyzed by SPSS18 using two-way ANOVA with P≤0.05 set as the level of significance.
Results: The results of this study showed no significant difference between three pH values (P=0.08). The Calibra resin cement had the lowest value of solubility in distilled water and both pH of lactic acid. GC Fuji PLUS resin modified glass ionomer cement had the highest value of solubility in lactic acid and the Maxcem resin cement had the highest value of solubility in water.
Conclusion: The solubility characteristics of resin modified glass ionomer and three different resin cements were significantly affected by their composition and the storage condition.