Volume 16, Issue 2 (7-2017)                   jhosp 2017, 16(2): 27-35 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

meidani Z, moosavi G, hamidian Y, farzandipour M, aliasgharzadeh A, nazemi bidgoli Z. Assessing the Appropriate Utilization of CT Scan in Triage Units. jhosp 2017; 16 (2) :27-35
URL: http://jhosp.tums.ac.ir/article-1-5552-en.html
1- Associate Professor, Health Information Management Research Center, Kashan University of Medical Sciences, Kashan, Iran
2- Instructor, Department of Epidemiology and Biostatistics, School of Public Health, Kashan University of Medical Sciences, Kashan Iran
3- Assistant Professor, Department of Radiology, School of Medicine, Kashan University of Medical Sciences, Kashan, Iran. Yaserhamidian@yahoo.com
4- Associate Professor, Health Information Management Research Center, Kashan University of Medical Sciences, Kashan, Iran.
5- Associate Professor, Department of Medical Physics, Kashan University of Medical Sciences, Kashan, Iran.
6- MSc in Management and Health Information Technology, Health Information Management Research Center, Kashan University of Medical Sciences, Kashan, Iran
Abstract:   (6758 Views)

Background: Regarding to the importance of controlling health care expenditure, necessity for proper distribution of health care resources and appropriate utilization of hospital resources through inappropriate services reduction for patients, this study aimed to assess suitability of brain CT scans, based on American College of Radiologists (ACR) appropriateness criteria in Shahid Beheshti Hospital affiliated to Kashan University of Medical Sciences (KAUMS).

Materials and Methods: This cross sectional and retrospective study was conducted in internal and surgery triage unites of an academic hospital in KAUMS to determine the appropriateness of brain CT scans. A General physician reviewed 361 medical records of patients through the check list based on ACR appropriateness criteria. Collected data was classified in three areas including appropriate, possibly appropriate and inappropriate. Data was analyzed using SPSS through descriptive statistics such as Index of dispersion  and chi-square test.

Results: Study findings revealed that among delivered CT scans, 310 (85.9%) appropriate, 38(10.5%) possibly appropriate and 13(3.6%) were inappropriate. The maximum and the minimum inappropriate brain CT scans rate 4 (4.17 %) were related to patients with Ataxia and zero (0 %) were related to patients with Headache, respectively.

Conclusion: Based on ACR appropriateness criteria, Brain CT scans were not utilized appropriately. In order to depict utilization review of radiology procedure in Iran, Developing a national guideline is necessary. To detect the effective factors regarding formulating targeted intervention, more comprehensive studies in various hospitals, different specialty and radiology modality seems necessary. 

Full-Text [PDF 696 kb]   (2269 Downloads)    
Type of Study: Original Article | Subject: مدیریت مالی و اقتصاد در بیمارستان
Received: 2015/09/3 | Accepted: 2017/03/22 | Published: 2017/07/8

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by : Yektaweb