Taleb Askaripoor, Gholam Abbas Shirali, Rasool Yarahmadi, Elahe Kazemi,
Volume 8, Issue 1 (4-2018)
Abstract

Introduction: Extensive human and economic losses due to the fire accidents shows the necessity of scientifically dealing with major industrial fires, , investing in the development of fire protection technologies and determination of the most effective techniques to limit damages. This study is conducted to evaluate the effect of active and passive protection methods on reducing the level of fire risk, in the control room of a thermal power plant.

Material and Method: In the first phase of this study, fire risk level for buildings, goods, occupants and activities was calculated using Fire Risk Assessment Method for Engineering. In the second phase, from 36 sub-factors affecting risk level, three sub-factors of passive protection measures and two sub-factors of active protection measures were analyzed and modified, in reducing the fire risk level of occupants.

Result: The results of the present study showed that occupants’ fire risk level (20.64) is above the acceptable level. Correction of three sub-factors, including constant fire load, floor number, and changing the dimensions and area of the control room up to 40% and installing an automatic fire extinguishing system and training the occupants to use fire extinguishing equipment and emergency evacuation up to 33%, is effective in reducing the fire risk level.

Conclusion: Passive and active protection methods, despite their impacts on reducing the level of risk, cannot provide an acceptable level of fire safety independently. Therefore, combined use of these methods is essential to protect buildings and people, and prevent any interruption in the system’s activities.


Taleb Askaripoor, Majid Motamedzade, Rostam Golmohammadi, Mohammad Babamiri, Maryam Farhadian, Hamed Aghaei, Mohammad Ebrahim Ghaffari, Elahe Kazemi, Mehdi Samavati,
Volume 11, Issue 4 (12-2021)
Abstract

Introduction: Recent evidence indicates that lighting can affect physiological and neurobehavioral human functions, referred to as non-image forming (NIF) effects of lighteffects. This study aimed to determine the effects of illumination levels and correlated color temperature (CCT) on alertness and performance under NIF conditions.
Material and Methods: In this study, 22 participants were exposed to light at various levels of illumination, including very low illuminance (<5 lux, control) and light conditions with correlated color temperatures (CCT) of 4000 K, 8000 K, and 12000 K at 300 and 500 lux. The data collection process included recording the power of brainwaves (alpha, alpha-theta, beta, and theta), sleepiness and mood scales, and cognitive performance tests for sustained attention, psychomotor vigilance task (PVT), working memory, and inhibitory capacity.
Results: The results indicated that 500 lux light conditions at correlated color temperatures of 8000 and 12000K significantly reduced normalized alpha, alpha-theta power, subjective sleepiness, and performance compared to the dim light condition. Under illumination levels of 300 and 500 lux, there were no significant differences in the measured values of the variables.
Conclusion: Lighting interventions can be used as a supplement to other strategies for increasing alertness and performance in the workplace.