[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Registration :: Submission :: Current Issue :: Archive :: Contact :: Search ::
Main Menu
Home::
Journal Information::
Articles archive::
Indexing & Abstracting::
For Authors::
For Reviewers::
Registration::
Contact us::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Google Scholar Metrics

Citation Indices from GS

..
:: Search published articles ::
Showing 2 results for Sarafraz

H Bagheri , H Sarafraz , N Ansari , M.s Rastak , Gh Olyaie , Mr Gity ,
Volume 1, Issue 1 (1 2007)
Abstract

Background and Aim: scapular position is one of the most important parts of a comprehensive approach to evaluation of patients with suspected shoulder dysfunction.Muscular imbalance has further been suggested to be a leading cause of asymmetrical motions and positions of scapula.

Kibler Introduced Lateral scapular slide test (LSST) quantitatively measures scapular symmetry, scapular stabilizer strength and shoulder girdle dysfunction threshold .

The literature recommends a further study on the reliability of LSST by using precise instrument such as caliper. Therefore, the main goal of present study was to determine the inter rater reliability of the LSST by using the caliper in comparison with the tape in patients with shoulder pathology

Material & Method: The LSST was administered to twenty men patients with a mean age 37.19 of years.(SD:12.42).The distances between the inferior angle of scapula &T7 were recorded. Subjects were tested with arm in neutral, hands on hips and 90 degrees of abduction full internal rotation. All data for tape and caliper in 0,45 and 90 degrees of shoulder abduction  were analyzed with SPSS (V:11.5).

Results: The ICCs range of inter- rater reliability were respectively (0.56-0.76) and (0.73-0.88) for tape and caliper in 0,45 and 90 degrees of abduction. Differences between ICCs for caliper and tape are not statisticaly significant. The SEM range was from 6.78 to 9.29 mm for tape and from 4.33 to 8.19 mm for caliper.  

Conclusion&Discusion:  This study showed that inter rater reliability of LSST is questionable. Although ICCs for caliper are better than tape but in third position of the test in both measurement method ICC were low. Further research is needed.


Hosein Bagheri, Azade Shadmehr, Noroddin Nakhostin Ansari, Hadi Sarafraz, Fariba Pour Ahangarian , Leila Barin, Najmeh Zaker, Shohreh Jalaei,
Volume 1, Issue 4 (20 2008)
Abstract

Background and aim: The lateral scapular slide test (LSST) is used to determine scapular position and scapular asymmetry with the arm abducted 0, 45, and 90 degrees in the coronal plane. This test was introduced by Kibler. Assessment of scapular position is based on the derived difference measurement of bilateral scapular distances and the distance of inferior angle of scapula to spinous process of T7 vertebra. The purpose of this study was to assess the reliability of measurements (intra rater, inter rater, sensitivity and specificity) of LSST in assessment of scapular asymmetry and scapular dysfunction in patients with shoulder impairments.

Materials and Methods: Subjects:  Fifty-seven subjects participated in this cross sectional study.

Twenty seven subjects in shoulder impairment group (X=47.66, SD=11.64) and thirty subjects in normal group(X=33.53, SD=11.72). Three examiners measured the distance of inferior angle of scapula to spinous process of T7 vertebra at two sides in three different positions by a caliper verneer (accuracy: 0.01 mm). Position 1 involves of the shoulder in glenohumeral joint neutral. In position 2, the humerus is placed in a position of medial rotation with 45 degrees of shoulder abduction. In position 3, the upper extremity is placed in a position of maximal medial rotation with 90 degrees of shoulder abduction. The data were analyzed with SPSS (version: 11.5). ICCs and SEMs were calculated.

Results: The ICCs for intra-rater reliability were 0.87 to 0.97 for subjects without and with shoulder impairments and 0.63 to 0.79 for inter-rater reliability in subjects with shoulder pathology (involved side). The SEMs ranged from 0.57 to 0.86 cm for intra-rater reliability and from 0.79 to 1.20 cm for inter-rater reliability. Sensitivity of the test was high(80% to 100%) but specificity  was low (4% to 26%).

Conclusion : The lateral scapular slide test has high sensitivity and good to high level of intra rater reliability at three different test positions. The test showed low specificity and poor to fair inter rater reliability at three different test positions particularly at position 3.



Page 1 from 1     

فصلنامه توانبخشی نوین Journal of Modern Rehabilitation
Persian site map - English site map - Created in 0.06 seconds with 26 queries by YEKTAWEB 4766