[Home ] [Archive]   [ فارسی ]  
:: Main :: About :: Registration :: Submission :: Current Issue :: Archive :: Contact :: Search ::
Main Menu
Home::
Journal Information::
Articles archive::
Indexing & Abstracting::
For Authors::
For Reviewers::
Registration::
Contact us::
::
Search in website

Advanced Search
..
Receive site information
Enter your Email in the following box to receive the site news and information.
..
Google Scholar Metrics

Citation Indices from GS

..
:: Search published articles ::
Showing 33 results for Reliability

Maryam Fayazi, Shohreh Noorizadeh, Mehdi Dadgoo, Masoud Salehi,
Volume 6, Issue 1 (10-2012)
Abstract

 Background and Aim: Spasticity is a motor disorder characterized by a velocity dependent increase in tonic stretch reflex and tendon jerks, due to the hyper-excitability of the stretch reflex. Modified Tardieu Scale (MTS) is a clinical tool for assessment of spasticity. The purpose of this study was to investigate intra-rater reliability of the MTS for knee extensors and ankle plantar flexors muscles in adult subjects with chronic stroke.

 Materials and Methods: In an analytical cross sectional study, 17 participants (10 men ,7 women) with age range of 40-76 years and mean time post stroke of 20/79 (SD=20/55) in a convenient sampling took part in this test-retest study. Intra-rater reliability of spasticity with MTS was investigated by one un-experienced physiotherapist for knee extensors and ankle plantar flexors in two sessions over one week. 

 Results: Interclass correlation coefficient (ICC) values for R2-R1 as an indicator of spasticity in knee extensor and plantar flexors was good (ICC=0/66) and very good (ICC=0/87) and for knee extensors and ankle plantar flexors quality of muscle reaction was 0.80 and 0.92 respectively.

 Conclusion: The MTS has a good reliability in spasticity assessment of knee extensors and ankle plantar muscles after stroke. Probably MTS can be used as a reliable clinical tool to measure spasticity of lower extremity muscles in adult subjects with chronic stroke.



Naser Havaei, Mandana Rezaei, Ghadamali Talebi, Ali Reza Farnam,
Volume 6, Issue 2 (11-2012)
Abstract

Background and Aim: Developmental dysgraphia is a kind of learning disabilities in school students. Evaluation of the sensory and motor skills in hand  of these persons by appropriate, functional and real tests demonstrates that their fine and complex hand sensory-motor abilities are prerequisites of intervention planning.  Purdue Pegboard and Two-Point Discrimination Tests are used for evaluation of the hand motor and sensory skills respectively. This study was aimed to evaluate the test-retest reliability of these tests in students with developmental dysgraphia.

Materials and Methods: In this descriptive-analytic study hand sensory-motor skills were evaluated in 23 students with developmental dysgraphia (8-11 years) in Tabriz city by Purdue Pegboard and static and moving Two-Point Discrimination tests. Test-retest reliability of mentioned tests was done between and within examiners via intra-class correlation coefficient and independent t-test  was done for the comparison of the skills between girls and boys and right and left-handed students and Pearson correlation coefficient was calculated for the relationship between motor and sensory skills.

Results: Intra-class correlation coefficients of Purdue Pegboard, static and moving two-point discrimination tests for inter-session and intra-session reliability were ranged from 0.77 to 0.94 and 0.69 to 0.92 respectively. There was no significant relationship between motor and sensory skills (p>0.05).

Conclusion: Because of high reliability of these tests, it can be used them for evaluating the sensory-motor skills and intervention planning in students with developmental dysgraphia. Loss of relationship between motor and sensory skills can be related to the pathology of dysgraphia that needs further researches. 


Nasrin Salehi Dehno, Shohreh Noorizadeh Dehkordi, Mehdi Dadgoo, Masoud Salehi, Narges Meftahi,
Volume 6, Issue 2 (11-2012)
Abstract

Background and Aim: Spasticity is one of the symptoms that contributes to functional limitation in adults with cerebral palsy and characterized by a velocity dependent increase in tonic reflex due to the hyperexcitability of the stretch reflex. Modified Tardieu Scale (MTS) is a valid clinical tool for assessment of spasticity. The purpose of this study was to investigate Inter-rater reliability of the Modified Tardieu Scale (MTS) for hip adductors, knee extensors and ankle plantar flexors muscles in adult subjects with cerebral palsy.

 Materials and Methods: In an analytical cross sectional study, 30participants (11 men ،21 women, age range 20 to 40 years, mean age (26.57±4.8) with spastic cerebral palsy from Ra'ad Rehabilitation Goodwill Complexes in Tehran city in a convenient sampling took part in this study. Spasticity was measured by two physiotherapist for hip adductors, knee extensors and ankle plantar flexors with MTS during same session with ten minutes interval between assessment of two raters.

 Results: ICC values for R2-R1 as an indicator of spasticity in hip adductors, knee extensor and plantar flexors were 0.97, 0.88 and 0.81 respectively. Also ICC Values for quality of muscle reaction was 0.89 in hip adductors, 0.96 in knee extensors and 0.92 in ankle plantar flexors

Conclusion: MTS has a high reliability in spasticity assessment of adductors, knee extensors and ankle plantar flexors muscles, Probably MTS can be used as a reliable clinical tool to measure spasticity of lower extremity muscles in adult subjects with cerebral palsy.


Faezeh Mahmoudi Hashemi, Seyed Javad Mousavi, Behroz Attarbashi Moghaddam, Saeed Talebian, Shiva Mousavi,
Volume 7, Issue 1 (5-2013)
Abstract

 Background and Aim: The translation, cultural adaptation and validation of the Persian version of the American shoulder and elbow surgeons (ASES) were carried out in accordance with published guidelines.

Materials and Methods: The study was conducted on 100 athletes (25.96±5.81 years), which suffered from different shoulder disorders. When the translation and cultural adaptation of the original questionnaire was carried out on the standardized method, the participants were asked to complete a questionnaire booklet including the DASH, the Short Form General Health Survey (SF-36) and ASES questionnaires. In addition, 30 randomly selected patients were asked to complete the ASES questionnaire 48 hours later for the second time. After data collection the Statistical analysis was performed by using SPSS software.

Results: The Cronbach's alpha was used to indicate internal consistency. Cronbach's alpha was 0.91 for ASES. Test-retest reliability was quantified by use of the intraclass correlation coefficient. It was 0.91 for ASES questionnaire. The Pearson Correlation Coefficient was used for the questionnaire validation study. The DASH questionnaire showed high correlation of ICC=0.78 with ASES. The ASES showed moderate correlation of 0.48 to 0.62 with those of the various scales of the SF-36.

Conclusion: The Iranian ASES showed good reliability and validity and can be used for shoulder-specific patient self-assessment.


Sakineh Goljaryan, Giti Torkaman, Seyed Mohammad Firouzabadi, Ali Reza Sarmadi,
Volume 7, Issue 1 (5-2013)
Abstract

Background and Aim: In studies of the spinal circuits, change of Renshaw cell activity is measured by H´ response. For recording H' response, new electrical stimulation device was designed and built and the first recorded H' response in Iran was done. The purpose of this study was to investigate the intersession and intra-session reliability of peak amplitude of H´ response and its related intensity detected of new device.
Materials and Methods: Soleus muscles of dominant extremity in 6 subjects were tested in 3 sessions and 2 times in each session that intra-session interval was 20 minutes and intersession interval was 1 week.
Results: Peak amplitude and its related intensity exhibited intra-session and intersession reliability 0.92, 0.98, 0.86 and 0.9 respectively. Standard Error of Measurement was 0.37 and 0.47 for intrasession and 0.44 and 1.06 for inter session respectively.
Conclusion: Peak amplitude and its related intensity exhibited very high intra-session and intersession reliability.
Yasaman Jalilian, Mohammad Rahim Shahbodaghi, Zahra Soleymani, Shohreh Jalaei,
Volume 7, Issue 3 (9-2013)
Abstract

Background and Aim: The current research was performed to investigate validity measurement of Persian version of stuttering prediction instrument (SPI) in children among 3-8 years old who stutter and determination of its reliability.
Materials and Methods: Translation of the SPI Test was examined by using IQOLA's translation protocol and equalization. Then for determination of it's logical validity, expertise views were collected by means of the method of Lawasche content validity. 52 children who stutter were examined by SPI test and also SSI3 test and the cooper stuttering chronicity prediction checklist for determination of construct and concurrent validity. Internal stability was examined by using alpha ration and finally at the end, Persian version of SPI was completed by twice examination of 15 stutterer children with duration of 7-10 days concerning examination of reliability of test-retest. */1-+
Conclusion: Existing strong and meaningful correlation between SSI3 and SPI test and also between cooper chronicity prediction checklist and SPI test are indicative of good convergence of each part in SPI test. Finally, these analyses verify that all parts of the test are benefiting from proper reliability and validity.
Masoumeh Radaei, Azar Mehri, Mehdi Dastjerdikazemi, Shohreh Jalaei,
Volume 7, Issue 3 (9-2013)
Abstract

Background and Aim: Semantic test "Pyramid and Palm Trees"(PPT) Test was used for assessing cognition and semantic system in brain disorders, semantic dementia, Alzheimer disease and aphasia. This test was designed in 1992 by Howard and Patterson and includes both versions picture and word. It has validity and reliability. The aim of this study is to determine of validity and reliability of Persian picture version "Pyramids and Palm Trees" Test and compare with aphasia and normal adults.

Materials and Methods: In this cross - sectional study, 45 subjects included 15 Aphasia and 30 normal adults respectively the mean age and standard deviation of 53 (7.77), 53 (7.91) years participated. All of participants were matched in the age and sex, and education and bilingualism. In the first stage, the picture version PPT had given to 14 expert(11 Speech and language pathologists, 3 Linguists) in order to determine content and face validity. According to their comments, pictures that were very far from Persian culture were replaced with proportional pictures with Persian culture. Then the reliability was calculated by performance of PPT during an interval of 5-7 days in two stages for all of aphasia patients. In order to compare of results, PPT was performed on normal adults. Then, the results were analyzed by SPSS18 software. The statistic tests were included of lavashh correlation for validity, Intra-class correlation coefficients (ICC) for reliability and independent T-Test for comparison of scores mean of picture version PPT between aphasia and normal adults.

Results: ICC ranges for reliability were 0.88 – 0.93. Also difference of scores mean of picture version PPT between aphasia and normal adults were significant (p<0.05).

Conclusion: The Persian version PPT have validity and reliability. This study showed semantic disorder in aphasia patients in compared with normal adults. 


Maliheh Hadizadeh , Ehsan Sedaghat Nejad , Seyed Javad Mousavi, Saeed Talebian, Mohammad Parnian Pour,
Volume 7, Issue 3 (9-2013)
Abstract

Background and Aim: Accurate control of movement is one of the multiple components in skillful motor performance that can be impaired by disease. Trackingtests quantify the effects oftreatments designed toimprovecontrol of movement and they are considered as anideal protocol forimproving motor control. The purpose of the present study was to examine reliability of the control error during target tracking tasks in trunk region in sagittal transverse torque plane in healthy subjects.

Materials and Methods: Nine healthy subjects (4 females and 5 males) randomly performed target tracking tasks at levels of 0% to 80% Maximum Voluntary Exertions (MVE) and twelve different directions (0 ̊, 30 ̊, 60 ̊, …, 330 ̊) twice in upright standing posture. In this study, the tracking system included a moving target circle, which moved on a straight line in specific direction from 0 to 80% of individual MVE with speed of 6% MVE/S.The direction of isometric trunk exertion was presented to participants in the online visual feedback by a computer monitor positioned in front of them. Trunk controllability was determined by computing the control errors (Absolute Value Error from the Target [AVET], Error from the Target Path [ETP] and Error from the Target in the Target Path [ETTP]) during each performance. Relative reliability (Intra-class Correlation Coefficient [ICC]) of the control error in each direction was determined. Also absolute reliability (Standard Error of Measurement [SEM]) and Minimal Detected Change (MDC95) were computed.

Results:The results have shown that ICC for AVET, ETP and ETTP ranged from 0.81 to 0.99, 0.71 to 0.98 and 0.7 to 0.99, respectively. Also SEM for these variables ranged between 0.003- 0.013, 0.001- 0.009 and 0.003- 0.011, respectively and finally MDC95 ranged between 0.008 to 0.036 for AVET, 0.003 to 0.025 for ETP and 0.008 to 0.03 for ETTP.

Conclusion: The study showed high and very high reliability for control error measures during target tracking tasks in sagittal transverse torque plane in asymptomatic subjects. Therefore this performance may be used as a test in trunk controllability assessment.


Mohammad Hasan Azarsa, Azadeh Shadmehr, Nader Maroufi, Hossein Bagheri, Shohreh Jalaei, Seyed Mohsen Mir,
Volume 8, Issue 3 (7-2014)
Abstract

Background and Aim: Scapular muscles stabilization and neuromuscular control are important factors in shoulder function during dynamic activities. The three-dimensional pattern of integrated movement between gleno-humeral and scapula-thoracic joints is known as the scapula-humeral rhythm. More involved rotator cuff and scapular muscles causes more motor units are being recruited, therefore perhaps with loading on scapular muscles, can evaluate muscles role in scapular position more accurately and comprehensively.

 

Materials and Methods: Thirty male basketball players, aged between 20 to 40 years were recruited for modified lateral scapular slide test. The linear distance between inferior angle of scapula and spinous process of T7-8 was examined in 90 degrees of scaption without load and with 1 kg loading by two examiners in one session using the caliper. One of the examiners repeated the test in next week.

 

Results: Amount of inter and intra-rater intra-class correlation coefficient (ICC) for 90 degrees of unloaded scaption was 0.73 and 0.82, respectively and for 1 kg loading position was 0.54 and 0.86, respectively. Amount of standard error of measurement (SEM) in inter and intra-rater measurements for 90 degrees of unloaded scaption was 0.83 and 0.59 cm, respectively and for 1 kg loading position was 0.97 and 0.45 cm, respectively.

  

Conclusion: 1 kg loading in scaption, did not significantly improve the reliability of the test that shows the amount of load is not appropriate to activate the muscles in the athletes.

 

Keywords: Loading in scaption, Lateral scapular slide test, Athletes, Reliability .


Shahin Soltani, Mohammad Kamali, Hasan Ashayeri, Ali Chabok, Amin Sarabandi, Saeedeh Esmaeeli, Fatemeh Kakaei,
Volume 8, Issue 4 (10-2014)
Abstract

Background and Aim: Shifting paradigms about how to assess the support needs of person with intellectual disability, in 1980, posed necessity of design and development of appropriate tools more than ever. In this regard, American Association on intellectual and developmental disabilities developed the supports Intensity scale to respond the lack of an appropriate tool. The aim of this study was to do the cultural adaptation and evaluation of psychometric properties of supports intensity scale in adult people with intellectual disability.

 

Materials and Methods: In this descriptive – analytic study, 43 adult persons with intellectual disability participated. Translation and adaptation of the SIS through International Quality of Life Assessment (IQOLA ) protocol was done. Validity of the test was evaluated by qualitative content validity. Internal consistency and test-retest reliability were used for evaluation of reliability.

  

Results: Based on the IQOLA protocol, The SIS had easy translation and relatively good quality. According to results, all items of the test had content validity. Cronbach's alpha coefficients fall in the range (.80-.99) and ICC ranged from .90 to .99

 

Conclusion: The results of this study showed that the Persian version of the SIS has good validity and reliability for identifying pattern and intensity of needed supports in adult people with intellectual disability.

 

Key words: Adaptation, Validity, Reliability, Intellectual disability, Supports Intensity Scale


Khadijeh Otadi, Saeed Talebian, Mohammad Reza Hadian, Azadeh Shadmehr, Nooreldin Nakhostin Ansari, Saeed Emamdoost, Shiva Mousavi ,
Volume 9, Issue 2 (5-2015)
Abstract

Background and Aim: The calculated parameters of the center of pressure (COP) are suitable indicators for evaluating balance in patients after rehabilitation. Therefore, determining the reliability level of each parameter is a matter of great importance. This study tried to determine the reliability of some parameters of the COP sway in patients with myofascial neck pain in different postural situations.

  

Materials and Methods: The present study is a test-retest reliability design. Twenty patients with myofascial neck pain performed a single and a double leg test with open and closed eyes on a force plate and with open eyes on foam in three sessions with a 30 minute intervals for 30 seconds. Antero-posterior and medio-lateral sway range, mean velocity and mean area of sway were calculated.

  

Results: The mean velocity showed high reliability (0.98) in all situations, but the other parameters were variable in different situations.

  

Conclusions: The results showed that some COP parameters are highly reliable in assessment of patients with myofascial neck pain.

  

Keywords: Reliability, Myofascial neck pain, Center of pressure, Force plate


Pouneh Ghasemi, Maliheh Hadizadeh, Ehsan Sedaghat Nejad, Seyed Javad Mousavi, Mohammad Parnian Pour,
Volume 9, Issue 3 (7-2015)
Abstract

Background and Aim : The tracking tests are a known method to measure and quantify the performance of the neuromuscular system. They are also one of the accurate and flexible methods for measurement of the performance capacity of sensory-motor control or sensory-motor coordination. The purpose of the present study was to examine reliability of the torque error during trajectory tracking tasks in trunk region in torque-time plane in healthy subjects.

  

Materials and Methods: Twenty healthy subjects (7 female and 13 male) randomly performed target tracking tasks with two patterns (sinusoidal and saw shape). The sinus and saw tracking tasks had two periodic cycles included 10 seconds (3 cycles) and 15 seconds (2 cycles). The amplitude of the signal was set at about 30% to 70% of Maximum Voluntary Exertions (MVE) of each participant. The tracking tasks were performed in 6 directions of uniaxial exertion (flexion, extension, left and right rotation, and left and right lateral bending). Absolute error mean and the performance of the tracking task were determined by calculating Relative Root Mean Square Error (RRMSE) for each participant during each trial. Relative reliability (Intraclass Correlation Coefficient: ICC) of the error mean and RRMSE for all participants was determined. Also absolute reliability (Standard Error of Measurement: SEM) and Minimal Detected Change ( MDC95 ) were computed.

  

Results: The results have shown that ICC, SEM and MDC95 for error mean ranged from 0.5 to 0.87, 0.002 to 0.006 and 0.007 to 0.016, respectively. Also these variables for RRMSE ranged between 0.5- 0.86, 0.05- 0.024 and 0.065- 0.139, respectively.

  

Conclusion: The repeatability analysis showed high and very high reliability for torque errors ( Error Mean, RRMSE ) measures during trajectory tracking tasks in torque time plane in asymptomatic subjects. Therefore this performance can be used for quantification of trunk controllability and also mentioned variables as reliable parameters in researches.

  

Keywords: Reliability, Trajectory tracking tests, Torque error, Isometric trunk exertion


Leila Dehghan, Hamid Dalvand, Abbas Pourshahbaz,
Volume 9, Issue 4 (11-2015)
Abstract

Background and Aim: Mothers of children with cerebral palsy (CP) experience limitation in occupational performance because of caring of their children. It is proposed that the standard measurements need to be assessed their occupational performance problem. The aim of this study was to translate "Canadian Occupational Performance Measure (COPM) into Persian and to test its content validity and reliability in Iranian mothers of children with cerebral palsy.

Materials and Methods: It was a non experimental methodology study. After permission from innovators, COPM was translated into Persian language in three phases with respect to IQOLA project. Each of the items was validated by a panel of ten experts to review each item on “appropriate” and “not appropriate”. For examining test-retest reliability Iranians version of COPM was responded twice within at least two days or at most one week interval, by 30 Iranian mother of a child with CP in the rehabilitation clinic under the supervision of University of Social Welfare & Rehabilitation Sciences (USWR). We used to sample of convenience and non probability design for sampling. Then, data were analyzed with SPSS software from the aspects of content validity and test-retest reliability.

Results: Content validity rate of the Persian version demonstrated a high content validity (80.95±0.222). The Spearman correlation coefficients of the test and retest scores ranged from r=0.84 for performance to r=0.87 for satisfaction and this indicated a high correlation between scores and acceptable reliability of the Persian version of COPM.

Conclusion: It was concluded that the Persian version of COPM can be applied reliability to mothers of children with CP and it can be used for clinical as well as research purposes.

Key words: Canadian occupational performance measure, Mother, Cerebral palsy, Validity, Reliability


Fatemeh Ghasemi, Ali Amiri, Nader Maarufi, Ali Ashraf Jamshidi, Shohreh Jalaei,
Volume 9, Issue 5 (1-2016)
Abstract

Background and Aim: Reliability or unreliability of the results achieved from recording of surface electromyography of muscles has always been questioned. The aim of present study was to  measure the reliability of the delayed reaction time of muscle electromyography of the knee joints on the exposure of unexpected rotary turbulence in the transverse plane from the area of supporting surface.

Materials and Methods: Twenty healthy women from 19 to 30 years old and free from any clear deformities in the lower extremities were participated in the present study. Surface electromyography of the six knee musculature was carried out for every subject separately in 4 situations including: External Rotation (Ext Rot) from plantar area on the transverse plane with bent and straight knee, Internal Rotation (Int. Rot) with the same conditions, Single Leg Stance situation in 4 stages, and repeatability of Intra Session through intra-class correlation coefficients when the muscles are in action on the exposure of turbulence in four applied forms were analyzed.

Result: The results from 24 analyzed forms showed that 18 forms of muscles at the time of action had moderate to high repeatability (Monroe Classification)

Conclusion: Regarding reliability, the muscles indicated different amounts in onset latency time, on the exposure of rotary turbulence, according to joint angle and the direction of applying rotation on the transverse plane. In respect to direction of rotation, most of the muscles indicated more reliability on the exposure of external rotation turbulence (clockwise) in relation to internal rotation (anti-clockwise) and also regarding the joint angle in turbulences with straight knee in relation to turbulences with bent knee. 

Keyword: Knee muscles, Surface electromyography, Reliability, Rotational turbulence


Saba Seyyedin, Azar Mehri, Mehdi Dastjerdikazemi, Shohreh Jalaei,
Volume 9, Issue 5 (1-2016)
Abstract

Background and Aim: A Concrete and Abstract Word Synonym Test is a test which assessed semantic system in patients with acquired language disorder specifically semantic impairment. The aim of this study is to design a valid and reliable test for assessment of comprehension of concrete and abstract words in different types of aphasia.

 

Materials and Methods: The type of study is test construction and was computed as cross-sectional. First, a collection of words based on frequency were chosen in order to construct the test. These words were given to 15 experts (10 speech and language pathologists and 5 linguists) in 3 stages, in order to rate words with 0-100 scale. Then words, which had higher average than 90 score were chosen. After determining face and content validity, the test was performed on subjects. Subjects included 20 aphasic patients (12 men and 8 women) and 50 normal people (28 men and 22 women) ranging in age from 20 to 65 years. After 5 to 7 days, to determine reliability of test, test was performed on subjects again. Results of this study were analyzed by SPSS 16.

 

Results: Results showed that this test has a higher validity than %90. Coronbach alpha for internal consistency was 0.500. For investigation of test-retest reliability, mean difference of test scores in 2 stages of administration was significance (p<0.038). Pearson correlation coefficient between mean scores of patients in 2stages were 0.857 and ICC range was 0.857-0.923 that was significant (p<0.001). The cut of point of test was also 46. Comparison of mean scores of concrete and abstract word synonym test in patients and normal people and also in patient with temporal lesion showed significant difference (p<0.001).

 

Conclusion: A Concrete and Abstract Word Synonym Test is a proper tool for assessing semantic system in aphasic patients and it can indicate semantic impairment in these patients.

 

Keywords: Synonym comprehension test, Concrete and abstract words, Validity, Reliability, Aphasia, Semantic impairment.


Narjes Yarmohammadi, Mehdi Rassafiani, Ghodsieh Joveini, Hamid Reza Rostami, Akbar Biglarian, Fatemeh Behnia,
Volume 9, Issue 6 (3-2016)
Abstract

Background and Aim: Children with cerebral palsy have impaired quality of life for reasons such as sensory-motor impairments. There is no tool in Persian to examine quality of life of children with cerebral palsy based on their specific conditions. Therefore, the purpose of this study was to assess psychometric properties of the  Persian version of the parent report of the Quality of Life Questionnaire for adolescence with Cerebral Palsy (CP QOL Teen).

Materials and Methods: In this psychometrics measurement study, CP QOL (parent report) was translated to Persian based on the International Quality of Life Assessment Project (International Quality Of Life Assessment Project: IQOLA), and then its face validity, content validity, construct validity, and reliability were assessed. A convenient sample of subjects including 82 parents of adolescence with cerebral palsy (13-18 years old), were recruited.

Results: Face and content validity were obtained by parents and experts respectively. Content Validity Index was 0.62. There was a significant correlation between total score and subscales scores of the questionnaire and also, between total score and GMFCS. The intraclass correlation coefficient for the total score was 0.994. Also, cronbach's coefficient &alpha; for the internal consistency of all of the questions of the questionnaire were 0.996

Conclusion: Persian version of the parent report of CPQOL has acceptable reliability and validity. It is a useful assessment tool for evaluating the quality of life of adolescence with cerebral palsy.

Keywords: Reliability, Validity, Persian version of parent report of the quality of life questionnaire for adolescence with cerebral palsy.


Soraya Salehi Zahabi , Ali Ghorbani, Nahid Jalilehvand, Mohammad Kamali,
Volume 9, Issue 6 (3-2016)
Abstract

Background and Aim: Perception of words is one of the parameters that examine to assess the language skills, due to lack of appropriate test in this field, informal assessing was done and evaluating of Perception of words has been challenged. The aim of this study is to design and determine the characteristics of Picture perceptive Objective Vocabulary Test for normal Persian-speaking 6-13 years-old children in order to examine the perception of words accurately.

Materials and Methods: In this methodological study that was done cross-sectional, a list of words that had the ability to visualize, prepared. To determine the content validity index, 7 speech therapists were surveyed and were chosen 240 images of words, finally this test was done on 118 children (57 girls, 61 boys) in seven age groups. Reliability of this test was assessed by repeatability and internal consistency and correlation between children’s scores and their age was determined by Spearman’s correlation.

Results: Content validity index  for total of 240 words were 1. In assessing reliability of this test Spearman’s correlation and internal consistency were 0.87 and 0.83 obtained respectively. There was a significant correlation between children’s ability to respond and their age (p<0.0005).

Conclusion: Pictures test for assessing the ability for perception of words in different categories of 6-13 years old children have appropriate content validity and reliability. In the age range of the study, child's ability to perception of words increases with age.

Keywords: Picture Perceptive Objective Vocabulary Test, children, Validity and Reliability


Abbas Pourebrahim Omran , Mohammad Rahim Shahbodaghi, Salman Abdi, Mohammad Kamali,
Volume 9, Issue 7 (3-2016)
Abstract

Background and Aim: The concept of locus of control refers to the degree in which a person perceives daily occurrences to be a consequence of his or her own behavior. Some people accept responsibility of their own continued well-being and maintained improvement, but the others, particularly those who do not accept this responsibility, may be at risk of relapse. It recommends a kind of measurement in order to identify such persons so that further steps can be taken to inhibit the relapse before occurs. One of this measurement is Locus of Control of Behavior. The purpose of the present study is to translate the Locus of Control of Behavior (LCB) into Persian and investigation of validity and reliability of the scale.

Materials and Methods: In this research, 35 adults with stuttering and 35 non-stuttering were evaluated. After the translation of the test according to Protocol IQOLA and its equalization to Persian Language, content validity and face validity of it were determined by the opinions of experts. Then, for concurrent validity determination 35 adults with stuttering were examined by LCB and Rotters locus of control .In order to test reliability, test –retest and Cronbach,s alpha were used.

Results: Entirely relevant items had simple translation. The translation items had content and face validity. Correlation between the marks of LCB and Rotters locus of control was (p=0.000, r= %53). LCB has high Test-retest (p=0.000, ICC= %87) and internal reliability (p=0.000, &alpha;=%85).

Conclusion: The present research showed that the Persian version of the LCB is a reliable and valid tool for locus of control from the perspective of a person who is stutter.

Key Words: Stuttering, Reliability, Validity, Locus of Control of Behavior


Salman Abdi, Shohreh Jalaei, Mohyeddin Teimouri Sangani , Ahmad Pourmohammad,
Volume 9, Issue 7 (3-2016)
Abstract

Background and Aim: There are various questionnaires to assess public attitudes towards various human traits but few standard tools to evaluate public attitudes about stuttering. The purpose of the present study was to translate the Public Opinion Survey of Human Attributes -Stuttering (POSHA-S) into Persian and investigation of psychometric properties of the scale.

Materials and Methods: Thirty adults without stuttering (8 men and 22 women) who have mean age of 24.9 participated in this developmental test study. After taking permission from test design, the translation of the test according to Protocol IQOLA and its equalization to Persian Language, face validity of it were determined by the opinions of participants. Then, Test-retest reliability of the scale was carried out by two methods; Pearson correlation coefficient and determination of point-to-point agreement.

Results: Entirely relevant items had simple translation. The translation items had face validity. The results showed that there was a high correlation between two completions in the whole questionnaire (p=0.000, r=0.70).

Conclusion: The present research showed that the Persian version of the "Public Opinion Survey of Human Attributes –Stuttering" is a reliable and valid tool. Therefore, the Persian version of this test can be used as a valid and reliable scale to assess community attitudes towards stuttering

Key Words: Stuttering, Reliability, Validity


Vahid Nejati, Somayeh Ramesh,
Volume 9, Issue 7 (3-2016)
Abstract

Background and Aim: Proverb comprehension can be used to assess cognitive function. Since tests of proverb comprehension impressed by language and culture, designing proverb comprehension test in Persian is necessary in order to evaluate cognitive and executive function. The purpose of the present study was to design a proverb comprehension test and to determine its validity and reliability.

Material and Methods: The present, Proverb Comprehension Test includes two subscales of out context and in context. The statistical population of the study were students of elementary and high schools in 1393-1394. The sample included 234 student with age range 10 to 18 years old that selected by Convenience Sampling scheme. Two halves method and Cronbach's alpha test were used in order to evaluate internal consistency. Discriminative validity was achieved from comparing average scores of age groups. For investigation of concurrent validity, Pearson test was used between results of proverb comprehension test and verbal fluency test.

Results: Subscales of out context  Proverb Comprehension Test with verbal fluency test had positive significant relationship. Cronbach's alpha coefficient of subscales of out context, in context and the total test was respectively 0.76, 0.72 and 0.88 and the reliability coefficient of two halves method was 0.82. Comparing between groups indicated the discriminative validity of the test.

Conclusion: Proverb Comprehension Test is a valid and reliable test for measuring executive and verbal functions.

Keywords: Proverb Comprehension, Reliability, Verbal fluency, Validity



Page 1 from 2    
First
Previous
1
 

فصلنامه توانبخشی نوین Journal of Modern Rehabilitation
Persian site map - English site map - Created in 0.08 seconds with 43 queries by YEKTAWEB 4741