1392/1/25، جلد ۴۰، شماره ۲، صفحات -

عنوان فارسی
چکیده فارسی مقاله
کلیدواژه‌های فارسی مقاله

عنوان انگلیسی Screening for Microalbuminuria in the early detection of diabetic nephropathy: A cheap and simple method
چکیده انگلیسی مقاله Prompt detection of renal involvement through evaluation of microalbuminuria can both reduce mortality in diabetic patients and significantly reduce the cost of managing these patients. To this end, Micral test strips have been used as a screeing tool in this group of patients though not yet in our country. The present study aimed to evaluate this test and to abtain a simpler and less expensive method of screening for microlbuminuria. In this study, 200 type 1 and type 2 diabetic patients referred to the Endocrine & Metabolims Research Center of the Tehran university of medical Sciences were evaluated for microabluminuria. Entry criteria consisted of a history of recognized diabetes longer than or equal to 5 years. Exclusion criteria included development of urinary tract infection, pyrexia, and a history of uncontrolled hypertension. Every patient first completed a data questionnaire and then provided a first-void urine sample, which was tested for microalbuminuria with a urinary protein test strip (an Iranian-made Uri-Yab and a German-made BM-test-GP strip) and the sulphasalicylic acid chemical method. Negative samples were tested further using Micral test strips (based on gold-lable immunochromatograpy) and the microalbumin measurement kit manufactured by Dako. Germany (based on turbidometry using a Hitachi autoanalyser). 126 women and 74 men were recruited into the study. The average age of the sample was 40.7 years (range=16 to 63 years); 17 patients had IDDM and 173, NIDDM. Average duration of recognized diabetes was 8.75 years. Based on results obtained using chemical analysis and foreign-made tests strips, 46 patients (23%) had macroalbuminuria, though the detection rate using Iranian-made test strips was 18 percent (36 patients). A further 16.2 percent of patients had microalbuminuria, with an average urinary albumin excertion of 28.7 mg per liter. Compared with colorimetric methos, the Micral test yieled a sensitivity of 93% and a specificity of 87 percenct. Furthermore, the negative predictive value of the Micral test was 0.92, compared with a figure of 0.94 for a combination of the sulphasalicylic acid method and the BM-Test-GP strips. The results we obtained for the Micral test as a screening tool concurs with the results of numerous other studies. Diurnal variations in albumin excretion dicatate the performance of screening tests on three different occasions at specified regular intervals. Given the relatively high cost of Micral strips, it seems that a simpler and less expensive method should be devised for our country. We observed a higher negative predictive value for the combined suluphasalicylic+BM-Test-GP method than for the Micral strips. The cost of the latter combination comes to 2,000 Rials (@0.25 USS) , which is easily affordable for most patients; the methodology falls comfortably within the experits of medical diagnostic laboratories in Iran. More detailed studies, using 24-
کلیدواژه‌های انگلیسی مقاله Micral test,

نویسندگان مقاله 37299---37300---37301---37302---37303---37304---

نشانی اینترنتی http://acta.tums.ac.ir/index.php/acta/article/viewArticle/2606
فایل مقاله فایلی برای مقاله ذخیره نشده است
کد مقاله (doi)
زبان مقاله منتشر شده en
موضوعات مقاله منتشر شده
نوع مقاله منتشر شده Article(s)
برگشت به: صفحه اول پایگاه   |   نسخه مرتبط   |   نشریه مرتبط   |   فهرست نشریات