Volume 71, Issue 6 (September 2013)                   Tehran Univ Med J 2013, 71(6): 373-381 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Moradi M, Nili F, Nayeri F, Amini E, Esmaeilnia T. Study of Characteristics, risk factors and outcome for Ventilator Associated Pneumonia in Neonatal Intensive Care Unit patient. Tehran Univ Med J 2013; 71 (6) :373-381
URL: http://tumj.tums.ac.ir/article-1-5426-en.html
1- , fnili@sina.tums.ac.ir
Abstract:   (11234 Views)
Background: Ventilator Associated Pneumonia (VAP), developing in mechanically ventilated patients after 48 hours of mechanical ventilation, is the second most common nosocomial infection. Therefore, there is a vital need to study the etiology and risk factors associated with VAP in neonates.
Methods: Neonates admitted to neonatal intensive care unit (NICU), over a period of one year and who required mechanical ventilation for more than 48 hours were enrolled consecutively into the study. Semi-quantitative assay of endotracheal aspirate was used for microbiological diagnoses of VAP. 105CFU/ml was taken as the cut off between evidence of pathological infection and colonization. The primary outcome measure was the development of VAP. Secondary outcome measures were length of mechanical ventilation, NICU length of stay, hospital cost, and death.
Results: Thirty eight patients were enrolled (58% were boys and 42% were girls). 42% of neonates developed VAP. The most common VAP organisms identified were Acinetobacter baumanni (43%). On multiple regression analysis, duration of mechanical ventilation was associated with VAP (P=0.00). Patients with VAP had greater need for mechanical ventilation (18.7 vs 6 median days), longer NICU length of stay (39 vs 21.5 median days) and higher total median hospital costs (79.5 vs 52 million rials) than those without VAP. The mortality rate was not different between two groups.
Conclusion: In mechanically ventilated neonates, those with VAP had a prolonged need for mechanical ventilation, a longer NICU stay, and a higher hospital costs. Longer mechanical ventilation was associated with an increased risk of developing VAP in these patients. Developing of VAP didn’t increase mortality in patients.
Full-Text [PDF 298 kb]   (4917 Downloads)    

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by : Yektaweb