Background: The aim of this study was to evaluate the mechanical and infectious complications of continuous ambulatory peritoneal dialysis catheter in surgical wards of Imam Khomeini Hospital.
Methods: We retrospectively reviewed 80 catheters that were inserted into 69 patients (52 men and 28 women) with end-stage chronic renal failure during a period of 84 months (13 Nov. 1996 to 13 Nov. 2003.
Results: The mean age of patients was 48:35 years (16 to 79 years). The most common complications were infectious ones (71.25%), while the most common causes of the catheter removal were mechanical ones (46.5% vs. 39.55%. The predominate cause of the mechanical complications was improper position (17.5%). Migration of catheter to upper abdomen and outflow failure were the other common mechanical complications. The most common infectious complication was peritonitis (62.5%).
Conclusions: The occurrence of the mechanical complications is lower than the infectious ones, but the probability of catheter loss is higher if it occurs.