Showing 5 results for Akbarzadeh-Baghban
Raheleh Dorosti , Mehri Ghasemi , Khosro Khademi-Kalantari, Alireza Akbarzadeh-Baghban ,
Volume 75, Issue 7 (October 2017)
Abstract
Background: Patellofemoral pain syndrome (PFPS) is known as one of the most frequent knee diseases and is the most frequent cause of anterior knee pain. Despite the high prevalence of the disease, its predisposing factors are not clearly known. Neuromuscular control disorders of hip and lumbopelvic complex and instability of core redounds to instability of whole movement pack chain. The aim of the present was to comparing the electromyographic activities of core muscles and muscles around the knee joint during gait in patients with PFPS with healthy subjects.
Methods: This descriptive-analytic case-control study was carried out in School of Rehabilitation in Shahid Beheshti University of Medical Sciences, Tehran, Iran. The present study was carried out during 10 months (April to February in 2016). Thirty-two subjects containing 17 patients with patellofemoral pain syndrome (10 females and 7 males) and 18 healthy subjects (10 females and 8 males) participated in this study. In both groups the electrical activities of some of the muscles around the knee joint and the core muscles containing vastus medialis (VM), adductor longus (AL), gluteus maximus (G Max), external oblique abdominis (EOA), internal oblique abdominis (IOA), transverse abdominis (TA) and multifidus (M) were recorded during gait. Onset and offset time, duration and intensity of muscles activities were compared between two groups.
Results: The results of the study showed that duration and intensity of the electrical activity of the gluteus maximus (respectively P=0.03, P=0.035) and offset time of electrical activity of the internal oblique abdominis (P=0.04) and the transverse abdominis (P=0.03) during gait, were significantly different between two groups. The external oblique abdominis and the multifidus electrical activities had not any significant differences between two groups (P>0.05).
Conclusion: It seems that electromyographic activities of some of core muscles in patients with patellofemoral pain syndrome in comparison with healthy subjects are different. However, there was no differences in electromyographic activities in some of the muscles around the knee between patients and healthy subjects.
Razieh Nazari , Mehri Ghasemi , Farideh Dehghan-Manshadi , Alireza Akbarzadeh-Baghban ,
Volume 75, Issue 9 (December 2017)
Abstract
Background: Sonography is used for measuring the muscle morphology including length, depth, cross-sectional area, bulk and pennation angle. The supraspinatus is the most common affected muscle among the rotator cuff muscles. There is no study about the reliability of sonographic measurement of supraspinatus thickness in the positions of empty can (EC), full can (FC) and hug up (HU) tests. The present study aims to investigate the intra-rater reliability of the measurement of sonographic thickness of supraspinatus muscle in the rest and positions of the EC, FC and HU tests.
Methods: The present study was a descriptive-analytic study which was carried out in a cross-sectional method on ten healthy women aged: 22.10±2.76 years without any tendon pathology. The study was carried out during four weeks (January to March in 2017). The supraspinatus thickness was scanned during rest and contracted states. The positions of measuring ultrasonic thickness of supraspinatus were as follow: position of EC test: the arm in 90-degree elevation in the scaption plane with the thumb-down, position of FC test: the arm in 90-degree elevation in the scaption plane with the thumb-up, position of HU test: the palm of hand was placed on the opposite shoulder with the elbow flexed using a 0.5-kg weight cuff. Intra-rater reliability of ultrasonic muscle thickness measurements were examined in one day.
Results: All intra-rater reliability values were equal or more than 0.90: the value was 0.90 (95%CI: 0.65-0.97) in the rest position, while for the measurement of ultrasonic thickness of the supraspinatus was 0.96 (95%CI: 0.87-0.99) in the position of EC test, 0.97 (95%CI: 0.90-0.99) and 0.96 (95%CI: 0.86-0.99) in the positions of FC and HU tests, respectively.
Conclusion: Measurement of ultrasonic thickness of supraspinatus muscle is a reliable method in the rest and positions of EC, FC and HU tests. This method can be used to compare the muscle thickness changes in the positions of the above tests.
Tayebeh Mirhashemi , Mehri Ghasemi , Frideh Dehghan-Manshadi , Alireza Akbarzadeh-Baghban , Alimohammad Faizi , Alireza Sabbaghian ,
Volume 76, Issue 5 (August 2018)
Abstract
Background: Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to investigate the intra-rater reliability of the ultrasonic thickness measurement of the supraspinatus, deltoid and upper trapezius muscles in women with frozen shoulder and healthy women.
Methods: This study was carried out during 4 months (June to October 2017). Twenty women consisted of 10 patients with frozen shoulder (mean age: 51.6±9.41 years) and 10 healthy subjects (mean age: 35.5±8.22 years) participated in this study. The patients from some clinics and hospitals in Tehran, and healthy subjects consisted of some personals and students in the School of Rehabilitation of Shahid Beheshti university of Medical Sciences participated in the present study. Measurements of ultrasonic thickness of the upper trapezius, supraspinatus and deltoid muscles in rest position carried out by the same rater two times in 48 hours. Ultrasonography instrument with linear probe (frequency: 7.5 MHz) were used for measurement of muscle thickness in millimeter.
Results: Reliability of the ultrasonic measurements of the muscle thickness in patients and healthy subjects was respectively as follow: The upper trapezius muscle (0.81, 0.81), the supraspinatus muscle (0.90, 0.92) and the middle deltoid muscle (0.93, 0.96). The reliability of the ultrasonic measurements of the muscle thickness for the upper trapezius muscle and the supraspinatus muscle was higher in healthy subjects compared to the patients with frozen shoulder. The reliability of the ultrasonic measurements of the middle deltoid thickness for the patients and healthy subjects was similar.
Conclusion: It seems that ultrasonography is a reliable method for measuring the thickness of the muscles around the shoulder in patients with frozen shoulder and healthy subjects.
Razieh Nazari , Mehri Ghasemi , Farideh Dehghan-Manshadi , Alireza Akbarzadeh-Baghban ,
Volume 77, Issue 8 (November 2019)
Abstract
Background: Rotator cuff injuries are the most common causes of shoulder pain and supraspinatus muscle is usually involved. Clinical tests are available and inexpensive tools for assessment of shoulder dysfunctions. The empty can (EC) and full can (FC) tests are considered as shoulder gold standard tests. Recently, hug up (HU) test has been developed to assess the supraspinatus. So far, no ultrasonographic study has compared supraspinatus muscle thickness in these testing positions. The present study aimed to compare the supraspinatus muscle thickness in the hug up testing position with the full can and empty can testing positions in young and healthy women.
Methods: Forty healthy women (mean age 21.62±2.4 years) participated in this cross-sectional-comparative study from April to June 2018 in the Biomechanic Laboratory of Rehabilitation School, Shahid Beheshti University of Medical Sciences in Tehran, Iran. The supraspinatus muscle thickness was scanned during rest and contracted states with a 0.5 Kg weight cuff. For contracted states, (A) EC testing position: the arm was at 90º abduction in the scaption plane with the thumb-down, (B) FC testing position: the arm was maintained at 90º abduction in the scaption plane with the thumb-up, (C) HU testing position: the palm of hand was placed on the opposite shoulder with the elbow flexed.
Results: The Bonferroni test showed significant differences (P<0.001) between the muscle thickness in the rest and the testing positions. The muscle thickness in the empty can testing position was significantly less than the full can testing position (P=0.001), no significant difference was found between the muscle thickness in the hug up testing position compared to the full can and empty can testing positions.
Conclusion: All of the empty can, full can and hug up testing positions demonstrated increased mean muscle thickness when compared to the rest position and the greatest muscle thickness was in the full can testing position. It seems that supraspinatus muscle thickness in hug up testing position is similar with empty can and full can testing positions.
Banafshe Safaeifard, Mehri Ghasemi, Khosro Khademi-Kalantari , Alireza Akbarzadeh-Baghban, Yaghoub Shavehee,
Volume 79, Issue 4 (July 2021)
Abstract
Background: Posturography is a method in which the postural stability of adults is evaluated by measuring the center of pressure sway. This study aims to evaluate the reproducibility of measuring the center of pressure oscillation in standing position with internal perturbation in healthy young women with and without hyperkyphosis.
Methods: Ten women with dorsal hyperkyphosis with the mean age of 23.5±2.65 years and 10 healthy women with the mean age of 21.9±1.3 years (October 2018 to February 2019) were recruited for the study. Subjects were asked to perform rapid bilateral arm elevation while standing on a force plate. Standard deviation of the amplitude and The standard deviation of the velocity of the center of pressure sway in anterior-posterior, Medio-lateral directions and the area of sway were used for statistical analysis. Measurements were carried out by one examiner with a 1-day interval in The Biomechanics laboratory of The School of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences. The relative reproducibility of the measurements was calculated by Intra-class Correlation Coefficient (ICC), standard error of measurement (SEM) and minimal detectable changes (MDC).
|
Results: The intra-rater reliability of standard deviation of the center of pressure sway velocity and amplitude of both directions in both groups were more than 0.75. The intra-rater reliability of the area of the center of pressure sway in the healthy and hyperkyphosis group were 0.42 and 0.38 respectively.
Conclusion: Standard deviation of the amplitude and standard deviation of the velocity of the center of pressure sway can be considered as reliable variables for assessing static balance in young women with and without dorsal hyperkyphosis in future studies. However, the inconsistency of sway area especially in women with hyperkyphosis suggests that the use of it for differentiation between subjects and the assessment of the outcome of any interventions on the postural stability should be considered with caution.
|