Arbabi Sh, Ashjaei B, Mamishi S,
Volume 65, Issue 14 (3-2008)
Abstract

Background: There are many methods for removal of tracheobronchial foreign bodies but there are many situations where removal of a foreign body seems impossible and may require a major surgical procedure. Familiarity with each method improves physician decision making.
Case: A 17 months old baby with a history of foreign body aspiration suffered from long term pneumonia. There was a round shape foreign body in bronchoscopic view that could not be removed with standard methods, but was removed by application of Fogarty catheter Conclusion: Removal of round, spherical foreign bodies may be performed by Fogarty Catheter preventing surgical intervention.