Blood transfusion is commonly implemented to manage life and health-threatening conditions on a rapid and short-term basis. Over the years, ongoing technical advances have dramatically improved transfusion medicine to provide more safety and effectiveness. However, transfusion is still complicated with different adverse events that mainly induced by the presence of allogeneic leukocytes in the blood products. Several lines of evidence have shown that leukocytes in blood components are involved in the induction of febrile nonhemolytic transfusion reactions (FNHTRs), HLA alloimmunization and platelet refractoriness as well as the increased risk of the infectious diseases transmitted by leukotropic viruses including cytomegalovirus (CMV), human T-lymphotropic virus (HTLV)-I/II and Epstein-Barr virus (EBV). During current decades, introducing various leuko-reduction techniques have shown to be associated with less transfusion related adverse events and improved clinical outcomes. The lower incidence and severity of febrile transfusion reactions; reduced risk of transfusion related transmission of CMV or other leukocyte-associated infections, lowered incidence of alloimmune platelet refractoriness in addition to reducing risk of mortality and morbidity in patients are considered as clinical benefits of leuko-reduced products. Currently, by the use of 3rd and 4th generation of filters, the highest levels of leukoreduction in blood components have been achieved. Filtration techniques have also the advantages of being performed shortly after preparation of components (pre-storage) or post-storage even at the patient’s bedside. However, it seems that pre-storage depletion of leukocytes provides better protection than post-storage techniques due to the elimination of leukocyte-derived cytokines effects which are increasingly released during storage. Particularly in platelet products, the earlier depletion of leukocyte also favors less platelet-induced leukocyte activation which may be triggered by the interaction between either activated platelets or their released chemokines and residual leukocytes during storage. Despite the benefits attributed to leukoreduction of blood components, the global use of leukoreduced products is commonly hampered by its high cost especially in developing countries in which leukoreduction of blood components is usually limited to some patients with special conditions. In this review, after briefly introducing of some transfusion adverse events that are attributed to allogeneic leukocytes existed in blood products, the effects of leukoreduction process in the attenuation of these events will be discussed.
Background: Blood transfusion is common in infants. Due to the weakened immune system of newborns and the risk of blood transfusion complications, it is necessary to pay more attention following or after to blood transfusion. The aim of this study was to evaluate the frequency and risk factors of blood transfusions in hospitalized neonates.
Methods: A cross-sectional study was performed on 1106 infants admitted in the neonatal intensive care unit (NICU) of Mustafa Khomeini University Hospital, Tehran, Iran, from spring 2009 to 2012. Frequency and the reason for of blood components transfusion including fresh frozen plasma, platelets, whole blood, packed red blood cells, cryoprecipitate and relationship with gestational age, sex, birth weight, Apgar score, duration of hospitalization, use of mechanical ventilation were assessed. Statistical analysis was performed with SPSS statistical software, version 16 (IBM, Armonk, NY, USA) and statistical test, chi-square test, independent t-test and analysis of variance (ANOVA).
Results: Among 1106 infants admitted to the neonatal intensive care unit, 221 infants (%19.98) received blood products. 82 of all (37%) were female and 139 (%63) were female. 113 (51%) of neonate were preterm and 108 (48%) were term. From 361 times of blood transfusions, 121 infant (54.75%) received at least one blood product. The frequency of blood transfusion was between 39 and 1 times, with an average of 3.65 times per infant. Frequency of fresh frozen plasma infusion was 173 (47.9%), packed cell 122 (33%), platelet 32 (8.8%), cryoprecipitate 20 (5.1%) and whole blood 3 unit (0.83%). The most common causes for fresh frozen plasma transfusion was replacement therapy 140 (80%), for packed cell, to correct symptomatic anemia 68 (55.6%), for platelet transfusions was to prevent bleeding in neonates with thrombocytopenia 20 (62.5%) and cryoprecipitate for bleeding caused by DIC in 18 infant (90%). There was significant relation between frequency of blood transfusions with gestational age (P=0.002), birth weight (P=0.01), cause of hospitalization (P=0.001) using of ventilator (P=0.002), and length of hospital stay (P=0.001). |
Conclusion: With attention to the guidelines of blood transfusions and controlling factors affecting premature birth and low weight infants, reducing length of hospital stay and duration of mechanical ventilation, frequency and complications of blood transfusion can be effectively decreased.
Nowadays by screening and testing of donations and implementation of different measures of virus inactivation or virus removal, a good level of safety of plasma derived biological medicines has been achieved. Due to the possibility of emerging new pathogens investigation in this subject should be continued. |