Search published articles


Showing 2 results for External Fixator

Zehtab Mj, Ghorbani Amjad Gh, Sadat Mm,
Volume 66, Issue 8 (11-2008)
Abstract

Background: Proper knee function is essential for daily activity. Since almost all complex tibial plateau fractures involve soft tissue compromise, there is some controversy as to the best treatment method. Currently, progress toward indirect reduction and external fixation, such as the hybrid external fixator, with minimal complications is underway. Herein we evaluate the outcomes of complex tibial plateau function repaired with hybrid external fixation at one of the most important trauma centers in Iran. 

Methods: This case-series study involved the postoperative follow up (>6 months) of 20 patients with complex tibial plateau fracture repaired using hybrid external fixator at Sina Hospital from 2002-2004. We evaluated surgery complications and outcomes including soft tissue and skin necrosis, knee range of motion, degenerative joint disease, infection, neurovascular injury, ::::union:::: time, and knee score at final visit, among others.

Results: Of the original 20 cases enrolled in this study, five dropped out. All subjects were men, with a mean age 38.6 (18-74) years. The most common injury mechanism was motor vehicle accident mean time from trauma to surgery was 4.7 (1-15) days. Mean follow up duration was 11.6 (6-26) months. At the end of the study, 80% had good knee range of motion (>90 flexion), with knee scores of 80 or more for 60% of the subjects. Although all patients had had soft tissue injury, there was no postoperative soft tissue compromise. Two patients (11%) had postoperative infection, but ultimately recovered. Less time between trauma and surgery, less periarticular soft tissue injury, less operative manipulation of soft tissues, better articular congruency, and more stable and anatomical knee alignment are associated with better outcome and prognosis.

Conclusions: This procedure reduces operative complications, especially infection and soft tissue necrosis, and requires less rest, all of which results in a stable, aligned and functional knee joint. Furthermore, adding minimal open reduction and internal fixation (ORIF) may promote even better results.


Mohammadreza Effatparvar , Nima Jamshidi , Alireza Asghari Ardabili ,
Volume 75, Issue 2 (5-2017)
Abstract

Background: Application of Hybrid 6 degrees of freedom fixation could lead to space motion in each 3 anatomic plates together and decrease the time of complex deformities correction. This study is an investigation on the function of hybrid external fixation and the influence of it on decreasing the treatment time. About this case utilize of Ortho-SUV Frame (OSF) system is explained for the first time in Iran and report of its novel. These robotic systems are divided into two groups: active and passive, about active system all movements are done by actuators in joints and links. And in passive, the system needs an operator or patient to actuates Sturats by hand.

Methods: The femur bone has been investigated was non::::union:::: with deformity in sagittal, frontal and transversal planes. Ilizarov external fixation was applicate firstly, with this condition that the OSF systems jacks were replaced instead of simple rods in side of fracture. Software work was done on February of 2016 in Ayatollah Taleghani Hospital, Tehran, Iran. Fractures were happened in a car accident and some other operating were perforemed for this patient without any result.

Results: The correction of studied deformity needs 3 planar moving. Acting this movement by Ilizarov requirements 33 mm displacement in frontal plane, 12 mm horizontal distraction and 48 mm displacement in sagittal plane. Due to the rate of correction in Ilizarov which is 1 mm per day, this bone needs 93 days for general correction and three times changing in shape of rings connections. While, by using the hybrid external fixation, all displacements were corrected in 46 days and first connection had supported all planes.   

Conclusion: According to that the decreasing of treatment time is one of the main goal, the hybrid external fixation systems could be an appointment choice in complex deformities and replaced with some common fixation. In addition to, using of updated software increases the accuracy of displacement.



Page 1 from 1     

© 2025 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by : Yektaweb