Showing 6 results for Reproducibility
Izadi-Mood N, Sarmadi S, Heydari-Farzan F, Haeri H, Forouhesh-Tehrani Z,
Volume 69, Issue 4 (7-2011)
Abstract
800x600 Normal
0
false
false
false
EN-US
X-NONE
AR-SA
MicrosoftInternetExplorer4
Background: Cancer of uterine cervix is the second cause of death in women in the world and
the most common cause in developing countries. Because the majority of women with
invasive cervical cancer of the uterine have not previously undergone screening,
many clinicians assume that Pap smear has a high degree of accuracy but
problems such as false positive and false negative interpretations, as well as interobserver
variability have questioned its validity.
Methods : We retrieved 162 positive cervical
smears that had been originally interpreted as ASC-US, ASC-H,
LSIL, HSIL, SCC, AGC and adenocarcinoma from the cytology archives
of Women's Hospital in Tehran, Iran. The slides were rescreened by an
experienced pathologist and reclassified in the mentioned categories. All the 162
slides were reviewed by three more pathologists in a blind study using
interpretative criteria utilized in their daily routine to evaluate
interobserver reproducibility. To increase the level of interobserver
agreement, the diagnostic categories were reduced to squamous Vs.
glandular abnormalities and invasive (SCC
and adenocarcinoma) Vs.
non-invasive abnormalities.
Results : The results obtained in this study indicated slight interobserver agreement (k=0.26).
The most reproducible category was the invasive category (SCC
in addition to adenocarcinoma) and the least agreement was seen for HSIL
(k=0.19).
Conclusion: This study showed that reproducibility of cytological interpretation of
conventional Pap smears varies among interpretive categories and the overall interobserver
agreement is slight. Since convening on the reduction of interobserver
discrepancy in Pap smear interpretations necessitates more reliable information
of interpretative variability, larger studies need to be undertaken.
Razieh Nazari , Mehri Ghasemi , Farideh Dehghan-Manshadi , Alireza Akbarzadeh-Baghban ,
Volume 75, Issue 9 (12-2017)
Abstract
Background: Sonography is used for measuring the muscle morphology including length, depth, cross-sectional area, bulk and pennation angle. The supraspinatus is the most common affected muscle among the rotator cuff muscles. There is no study about the reliability of sonographic measurement of supraspinatus thickness in the positions of empty can (EC), full can (FC) and hug up (HU) tests. The present study aims to investigate the intra-rater reliability of the measurement of sonographic thickness of supraspinatus muscle in the rest and positions of the EC, FC and HU tests.
Methods: The present study was a descriptive-analytic study which was carried out in a cross-sectional method on ten healthy women aged: 22.10±2.76 years without any tendon pathology. The study was carried out during four weeks (January to March in 2017). The supraspinatus thickness was scanned during rest and contracted states. The positions of measuring ultrasonic thickness of supraspinatus were as follow: position of EC test: the arm in 90-degree elevation in the scaption plane with the thumb-down, position of FC test: the arm in 90-degree elevation in the scaption plane with the thumb-up, position of HU test: the palm of hand was placed on the opposite shoulder with the elbow flexed using a 0.5-kg weight cuff. Intra-rater reliability of ultrasonic muscle thickness measurements were examined in one day.
Results: All intra-rater reliability values were equal or more than 0.90: the value was 0.90 (95%CI: 0.65-0.97) in the rest position, while for the measurement of ultrasonic thickness of the supraspinatus was 0.96 (95%CI: 0.87-0.99) in the position of EC test, 0.97 (95%CI: 0.90-0.99) and 0.96 (95%CI: 0.86-0.99) in the positions of FC and HU tests, respectively.
Conclusion: Measurement of ultrasonic thickness of supraspinatus muscle is a reliable method in the rest and positions of EC, FC and HU tests. This method can be used to compare the muscle thickness changes in the positions of the above tests.
Tayebeh Mirhashemi , Mehri Ghasemi , Frideh Dehghan-Manshadi , Alireza Akbarzadeh-Baghban , Alimohammad Faizi , Alireza Sabbaghian ,
Volume 76, Issue 5 (8-2018)
Abstract
Background: Some studies show that frozen shoulder is due to the pathologic changes in the muscles around the shoulder. Measurement of the ultrasonic thickness of a muscle is a method for measuring the muscle changes. There is no study about the reliability of measurement of the muscle’s ultrasonic thickness around the shoulder in patients with frozen shoulder. The present study aims to investigate the intra-rater reliability of the ultrasonic thickness measurement of the supraspinatus, deltoid and upper trapezius muscles in women with frozen shoulder and healthy women.
Methods: This study was carried out during 4 months (June to October 2017). Twenty women consisted of 10 patients with frozen shoulder (mean age: 51.6±9.41 years) and 10 healthy subjects (mean age: 35.5±8.22 years) participated in this study. The patients from some clinics and hospitals in Tehran, and healthy subjects consisted of some personals and students in the School of Rehabilitation of Shahid Beheshti university of Medical Sciences participated in the present study. Measurements of ultrasonic thickness of the upper trapezius, supraspinatus and deltoid muscles in rest position carried out by the same rater two times in 48 hours. Ultrasonography instrument with linear probe (frequency: 7.5 MHz) were used for measurement of muscle thickness in millimeter.
Results: Reliability of the ultrasonic measurements of the muscle thickness in patients and healthy subjects was respectively as follow: The upper trapezius muscle (0.81, 0.81), the supraspinatus muscle (0.90, 0.92) and the middle deltoid muscle (0.93, 0.96). The reliability of the ultrasonic measurements of the muscle thickness for the upper trapezius muscle and the supraspinatus muscle was higher in healthy subjects compared to the patients with frozen shoulder. The reliability of the ultrasonic measurements of the middle deltoid thickness for the patients and healthy subjects was similar.
Conclusion: It seems that ultrasonography is a reliable method for measuring the thickness of the muscles around the shoulder in patients with frozen shoulder and healthy subjects.
Banafshe Safaeifard, Mehri Ghasemi, Khosro Khademi-Kalantari , Alireza Akbarzadeh-Baghban, Yaghoub Shavehee,
Volume 79, Issue 4 (7-2021)
Abstract
Background: Posturography is a method in which the postural stability of adults is evaluated by measuring the center of pressure sway. This study aims to evaluate the reproducibility of measuring the center of pressure oscillation in standing position with internal perturbation in healthy young women with and without hyperkyphosis.
Methods: Ten women with dorsal hyperkyphosis with the mean age of 23.5±2.65 years and 10 healthy women with the mean age of 21.9±1.3 years (October 2018 to February 2019) were recruited for the study. Subjects were asked to perform rapid bilateral arm elevation while standing on a force plate. Standard deviation of the amplitude and The standard deviation of the velocity of the center of pressure sway in anterior-posterior, Medio-lateral directions and the area of sway were used for statistical analysis. Measurements were carried out by one examiner with a 1-day interval in The Biomechanics laboratory of The School of Rehabilitation Sciences, Shahid Beheshti University of Medical Sciences. The relative reproducibility of the measurements was calculated by Intra-class Correlation Coefficient (ICC), standard error of measurement (SEM) and minimal detectable changes (MDC).
Results: The intra-rater reliability of standard deviation of the center of pressure sway velocity and amplitude of both directions in both groups were more than 0.75. The intra-rater reliability of the area of the center of pressure sway in the healthy and hyperkyphosis group were 0.42 and 0.38 respectively.
Conclusion: Standard deviation of the amplitude and standard deviation of the velocity of the center of pressure sway can be considered as reliable variables for assessing static balance in young women with and without dorsal hyperkyphosis in future studies. However, the inconsistency of sway area especially in women with hyperkyphosis suggests that the use of it for differentiation between subjects and the assessment of the outcome of any interventions on the postural stability should be considered with caution.
|
Yunus Soleymani, Amir Reza Jahanshahi, Hamed Rezaeejam, Davood Khezerloo,
Volume 80, Issue 12 (3-2023)
Abstract
Background: Radiomics is a noninvasive method that reveals information from medical images that are not recognizable by the naked eye. Radiomics has shown a high potential in the accurate diagnosis and prognosis of liver lesions in ultrasound images. Despite this high potential, changes in imaging parameters affect the reproducibility of ultrasound radiomics results. Therefore, the present study aims to investigate the reproducibility of the radiomics features extracted from the images of patients with hepatocellular carcinoma under changes in ultrasound scan parameters.
Methods: This was a cross-sectional study conducted from July 2020 to July 2021 in the radiology department of Tabriz Paramedical Faculty. The images of 20 patients with hepatocellular carcinoma were obtained from the Cancer Imaging Archive database. These images were taken under different imaging conditions and parameters. The areas related to the lesion were manually extracted from the images with software tools. Then, in order to radiomics analysis, different radiomics features, including 24 gray level co-occurrence matrix (GLCM) and 16 gray level run length matrix (GLRLM), were extracted from the images. Then, using the coefficient of variation (CV%) and intraclass correlation coefficient (ICC) statistical tests, the reproducibility of radiomics features under changes in scan parameters was investigated. The values of ICC≥0.90 and CV<20% were considered reproducible in this study.
Results: Among the 40 features extracted from ultrasound images, eight showed high reproducibility in both CV% and ICC tests. These features were joint entropy, Idmn, Imc2, correlation, MCC, sum entropy, gray level non-uniformity normalized, and run entropy in which the two features, Idmn and gray level non-uniformity normalized, showed the highest (CV%=0.24) and the lowest (CV%=14.90) stability against the changes of ultrasound scan parameters, respectively. The average ICC value of these features was obtained at 0.977.
Conclusion: Despite the high potential of radiomics in diagnosing liver lesions, changes in imaging parameters directly affect the reproducibility of results. However, some radiomics features still show high stability and reproducibility under changes in imaging parameters.
|
Babak Vahdatpour, Mohammad Shirvani, Hamidreza Jahanbani-Ardakani , Omid Alizadehkhaiyat , Sadegh Baradaran Mahdavi ,
Volume 81, Issue 4 (7-2023)
Abstract
Background: The objective of this study was the transcultural adaptation of the Rotator cuff quality of life (RC-QOL) questionnaire and the determination of the reliability and validity of the questionnaire in the Persian-speaking population with rotator cuff disease.
Methods: This study was conducted in Isfahan from April 2022 to February 2023. The participants consisted of 56 people with rotator cuff pathology. The process of adapting and translating the questionnaire was done with the methodology presented previously by Beaton et al. Content validity was first tested by a group of orthopedic and physical medicine and rehabilitation specialists and then through a pilot study consisting of 15 Persian-speaking patients with rotator cuff disease. Test-retest reliability was established with an intraclass correlation coefficient. Internal consistency was calculated using Cronbach's alpha. The measurement's error estimation was calculated with the standard error of the measurement. Reproducibility evaluation was measured with a 3-day interval between the completion of the test-retest questionnaire.
Results: The age range of the participants was 34 to 68 years (55% men and 45% women). The mean (standard deviation) of the total score of the RC-QOL questionnaire was 44.33(10.81) and ranged from 17.35 to 70.88. Cronbach's alpha was 0.971, which showed high internal consistency. The intraclass correlation coefficient was 0.99, indicating high test-retest reliability. The mean values (standard deviations) of the DASH and SPADI questionnaires were equal to 77.66(13.69) and 66.66(18.25), respectively. The results of the study showed excellent and significant convergent validity of the RC-QOL questionnaire with both the DASH and SPADI questionnaires. The correlation value with the DASH and SPADI questionnaires was equal to 0.907 and 0.941, respectively.
Conclusion: The Persian version of the RC-QOL questionnaire is a valid and reliable tool to evaluate the quality of life in patients diagnosed with rotator cuff injuries.
|