Niroomanesh Sh, Heidari A,
Volume 58, Issue 2 (5-2000)
Abstract

There are now several tests available that can assess fetal status. A series of 164 cases of high risk pregnancies were studied in order to assess predictive value of a nonstress test. The majority (36%) of patients complained about postdate pregnancy. A nonreactive test was identified in 24 of the patients (14.6%). Fetal distress, low Apgar score in 1 and 10 minutes after birth and mean of Apgar score in 5 minutes, cesarean section due to fetal distress, congenital anomalies, need of neonatal care, IUGR, abnormal presentation and perinatal death were much more common in the group of pregnancies with a nonreactive NST than in the group with reactive test. The difference was statistically significant. A reactive test was found to be a good predictor of the healthy fetus. Negative predictive value and specifity of the test were found 80% and 91.9%, respectively. The nonreactive test could identify a population at risk but it was not helpful as a stand alone modality in decision making, because of the low sensitivity and positive predictive value rates (33.3% and 58%).
Modarres M, Mir Mohammad Ali M, Haghani H, Arami R, Rahnama P,
Volume 64, Issue 9 (9-2006)
Abstract

Background: The most frequently used test for evaluation of fetal health is the Non Stress Test (NST). Unfortunately it has a high incidence of false positive results. The combination of vibroacoustic stimulation with the NTS has been shown to reduce non reactive results.
Methods: A tests assessment method was chosen with a simple randomized sampling. 40 pregnant women with non reactive NST in the first 20 minutes who received VAS in one of Tehran University's Hospitals were compared with BPP scores. A vibroacoustic stimulation was applied for a 3 seconds on the maternal abdomen and fallowed within 10 minutes.Data collection tools were NST, sonography instruments ,NST result paper, tooth brusher, watch, demographic questioner and check list. Data analysis was made by descriptive static and by using the Fisher's Exact Test (with level of significant at p<0/05). All statistical analysis were performed using an spss/win.
Results: After VAS, 70% of non reactive tracing became reactive. All cases with fetal reactivity response after a VAS had a subsequent BPP score of 8 (negative predictive value of 100%). False positivity of VAS was lower than NST.
Conclusion: VAS offers benefits, by decreasing the incidence of non reactive test and reducing test time. VAS lowers the rate of false positive NST. VAS is safe and allows more efficient of prenatal services. This test could be used as a rapid antepartum test to predict fetal well-being.
Sadeghian S, Sheikhvatan M, Hakki Kazazi E, Rouzkari M, Sheikhfathollahi M,
Volume 65, Issue 12 (3-2008)
Abstract

Background: The most common methods for screening of patients with probable ischemic heart disease are stress test and in special conditions are perfusion scan, so that their positive results was important indication of coronary angiography. Although, predictive value of perfusion scan has been considered, with regard to the impact of technical and specialized factors and according to the spread of this technique that has wrongly replaced the stress test, it is necessary to compare predictive value of this method with stress test in our country.

Methods: In a cross-sectional study, patients referred to Tehran Heart Center from all centers of country between January 2004 and January 2005 for coronary angiography was included. Demographic characteristics of patients were collected by interview and clinical tests and analyzed in two genders. Then, positive predictive value (PPV) of both techniques was calculated and compared.

Results: The total number of positive perfusion scan and stress test were 2178 and 2581, respectively. It was not significant difference between PPV of perfusion scan and stress test in men (86.9% vs 86.6%, P=0.814). PPV of perfusion scan was higher than stress test only in women more than 60 years old (P=0.0002).

Conclusions: According to the results of this study and with regard to high cost of perfusion scan, it seems that in case the possibility of stress test, the use of perfusion scan had no advantages with the condition of our scan centers and especially in women, predictive value of these techniques were similar. However, it is necessary to consider the causes of this unusual finding according to the role of drugs, instruments, and specialists in the future.