Volume 22, Issue 2 (7-2016)                   Back to this Issue | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Salimi M, Masoumpoor A, Shirinabadi Farahani A, Shakeri N, Alaee Karharoudy F, Shiri H. Auditing nursing care related to weaning neonates from mechanical ventilation in neonatal intensive care units. Journal of Hayat 2016; 22 (2) :159-174
URL: http://hayat.tums.ac.ir/article-1-1472-en.html
1- MSc. in Nursing
2- Ph.D in Nursing, Dept. of Pediatric and NICU Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran , masoumpoor.a@sbmu.ac.ir
3- Ph.D in Nursing, Dept. of Pediatric and NICU Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran
4- Dept. of Biostatistics, School of Paramedical Sciences, Shahid Beheshti University of Medical Sciences, Tehran
5- Ph.D in Nursing, Dept. of Pediatric and NICU Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran,
6- Dept. of Medical Surgical Nursing, School of Nursing and Midwifery, Shahid Beheshti University of Medical Sciences, Tehran
Abstract:   (10142 Views)

Background & Aim: Mechanical ventilation is one of the most common treatments in neonatal intensive care unit and is however associated with many complications. One of the ways to reduce complications is providing nursing care according to standards. This study was conducted with the aim of determining the conformity of nursing care related to weaning neonates from mechanical ventilation to the standards in neonatal intensive care units.

Methods & Materials: In this descriptive study (the audit), 105 nursing cares related to weaning neonates from mechanical ventilation in neonatal intensive care units at the selected hospitals affiliated to Shahid Beheshti University of Medical Sciences were selected and observed by the event sampling method in 2015. Data were gathered through a demographic questionnaire for nurses and hospitalized newborns, a checklist of nursing care related to weaning from mechanical ventilation. The data were analyzed using descriptive statistics and Chi-square test at the significance level less than 0.05.

Results: Conformity rate of nursing care related to weaning neonates from mechanical ventilation to standards, was 68.3 percent, and compliance with the standards of care was 71.4 percent before weaning, 65.7 percent during weaning and 66.4 percent after weaning.

Conclusion: Nursing cares related to weaning neonates from mechanical ventilation are far from standards, and for its improvement, applying clinical guideline for neonatal nursing care and clinical supervision by managers for optimizing its implementation are suggested.

Full-Text [PDF 197 kb]   (3596 Downloads)    
Type of Study: Research | Subject: Nursing Care
Published: 2016/08/22 | ePublished: 2016/08/22

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by : Yektaweb