Volume 28, Issue 4 (1-2023)                   Back to this Issue | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Abasian P, Hayrabedian A, Tarrahi M J, Ghadami A. The effect of using automatic mask dispenser on the contamination of surgical masks in the operating room. Journal of Hayat 2023; 28 (4) :434-448
URL: http://hayat.tums.ac.ir/article-1-4746-en.html
1- Dept. of Operating Room, School of Nursing and Midwifery, Isfahan University of Medical Sciences, Isfahan, Iran; Student Research Committee, Isfahan University of Medical Sciences, Isfahan, Iran
2- Dept. of Operating Room, School of Nursing and Midwifery, Isfahan University of Medical Sciences, Isfahan, Iran; Nursing and Midwifery Care Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
3- Dept. of Epidemiology and Biostatistics, School of Health, Isfahan University of Medical Sciences, Isfahan, Iran; Behavioral Sciences Research Center, Isfahan University of Medical Sciences, Isfahan, Iran
4- Dept. of Operating Room, School of Nursing and Midwifery, Isfahan University of Medical Sciences, Isfahan, Iran; Nursing and Midwifery Care Research Center, Isfahan University of Medical Sciences, Isfahan, Iran , ghadami@nm.mui.ac.ir
Abstract:   (1059 Views)
Background & Aim: Hand disinfection methods are not germ-free, and infected hands transmit the infection. One of the personal protective equipment of the operating room is the mask, which will probably be contaminated by the hands when removing the mask. The aim of this study is to determine the effect of using automatic mask dispenser on the contamination of surgical masks in the operating room.
Methods & Materials: The present study is a field experiment that was conducted on 120 hospital staff in Isfahan in 2021. The subjects were randomly divided into two groups of 60; automatic device and manual mask removal. The effect of contact of hands impregnated with fluorescent powder was measured during the removal of the mask in each group. The contamination area of ​​the removed mask and the lower mask on the back and front surfaces were compared in the two groups.
Results: The Mann-Whitney test showed that there was a significant difference in the area impregnated with fluorescent powder from hand contact with the mask surface between the two methods (P<0.05). Only 125.6±77.8 mm2 of from the front surface and 30.6±26.0 mm2 from the back surface of the mask removed with the automatic mask dispenser were contaminated, while the ratio in the hand-removed mask was respectively 961.6±612.9 and 440.4±315.6 mm2.
Conclusion: The study showed that eliminating hand contact with the body of the mask using an automatic mask dispenser, can reduce its contamination. Therefore, mechanization of services is effective in ensuring the safety of individuals’ health and reducing costs.
Clinical trial registry: IRCT20150715023216N11

 
Full-Text [PDF 510 kb]   (675 Downloads)    
Type of Study: Research | Subject: Nursing Care
Published: 2023/03/15 | ePublished: 2023/03/15

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by : Yektaweb