Volume 13, Issue 3 (11-2020)                   ijhe 2020, 13(3): 455-468 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Jalali Sarvestani M R, Doroudi Z. Uultra-trace determination of cadmium (II) in aqueous environmental samples by a new ion selective electrode based on nefazodone and 1-butyl-3-methylimidazolium hexafluorophosphate ionic liquid. ijhe 2020; 13 (3) :455-468
URL: http://ijhe.tums.ac.ir/article-1-6469-en.html
1- Young Researchers and Elite Club, Yadegar-e-Imam Khomeini (RAH) Shahre-rey Branch, Islamic Azad University, Tehran, Iran
2- Department of Chemistry, Yadegar-e-Imam Khomeini (RAH) Shahre-rey Branch, Islamic Azad University, Tehran, Iran , Zohreh.Doroudi@gmail.com
Abstract:   (1276 Views)
Background and Objective: Cadmium is a potential environmental contaminant that causes adverse effects on the environment and the health of living organisms. Therefore, designing a simple and economic technique for its determination is very important. In this respect, a potentiometric sensor based on nefazodone as the ionophore and [BMIM]PF6 as the ionic additive were developed for the determination of ultra-trace amounts of cadmium (II),.
Materials and Methods: In this study, a new membrane ion selective electrode was constructed with a composition entailed of 10% nefazodone, 2% [BMIM]PF6, 30% PVC and 58% dioctyl phthalate (DOP).The created potential discrepancy between the membrane and reference electrodes was used as a signal which demonstrates a direct relationship with the logarithmic concentration of cadmium (II) for  its determination.
Results: The constructed sensor showed an appropriate Nernstian slope (30.5 mV. Decade-1) in a wide concentration range (1×10-9 - 8×10-2 M) with the detection limit of 6×10-9 M. The electrode potential was pH-independent in the range of 3.5-8.0. The response time and lifetime of the electrode obtained 5 s and 15 weeks, respectively.
Conclusion: The constructed sensor independent of sample preparation was employed successively for the measurement of low concentrations of cadmium (II) in the environmental samples .Moreover,  the obtained findings were in a good agreement with the results of flame atomic absorption spectroscopy. Therefore, the designed electrode established pinpoint accuracy and it can be used for the determination of cadmium (II) in aqueous samples.
Full-Text [PDF 1416 kb]   (522 Downloads)    
Type of Study: Research | Subject: WATER
Received: 2020/10/10 | Accepted: 2021/01/20 | Published: 2021/07/18