Baghal Asghari F, Nikaeen M. Sensitivity Comparison of Different 16s rDNA- Specific Primers for Detection of Legionella Species in Aquatic Samples. ijhe 2012; 5 (3) :263-272
URL:
http://ijhe.tums.ac.ir/article-1-9-en.html
1- , nikaeen@hlth.mui.ac.ir
Abstract: (8846 Views)
Background and Objectives: Legionella are gram-negative bacteria widely dispersed in
natural and man-made water sources. Some Legionella species are pathogenic and
could cause respiratory infections. Cultivation technique is the conventional
method for the detection of Legionella spp. in aquatic samples. However, the
method has low sensitivity and require prolonged incubation period. Therefore,
Polymerase chain reaction (PCR) as a rapid method with extreme sensitivity is
used. The present study was designed to evaluate the feasibility and
sensitivity of PCR method for detection of Legionellas pp. in aquatic samples
using three sets of primers.
Materials and Methods: In this study, 60 water samples were investigated for the presence of
Legionella species using Nested- PCR technique. The sensitivity of this
technique was evaluated for the detection of Legionella species in aquatic
samples using three primer sets, including (LEG225-LEG858), (LEG448-LEG858),
and (LEG448-JRP).
Results: The nested
PCR assay revealed that detection percentage of Legionella in samples was 70
when LEG448-JRP primers were used, whereas this percentage reduced to 50 and 45
when we applied prime sets of LEG225-LEG858 and LEG448 - LEG858, respectively.
Conclusion: The
results of the study showed that contamination of aquatic samples to the
Legionella spp. could be easily and rapidly detected by nested PCR. However,
selecting appropriate method for DNA extraction and choosing the primers are
important factors in efficiency and sensitivity of detection method.
Type of Study:
Research |
Subject: