Abstract:   (5265 Views)
Statement of Problem: Rotary dental instruments (i-e. iow speed and high speed handpieces), due to infection spread high potentiality, should be sterilized between dental visits for each patient. When a high speed rotary instrument pauses at a high velocity, contaminated fluids like blood and saliva will be sucked into its tubes.
Purpose: The aim of this study was to compare the bactericidal effects ofDeconex 53 plus solution and the solarsept spray on dental high- speed instruments.
Materials and Methods: In this experimental study, one hundred and twenty (120) dental high- speed turbines, sterilized by autoclave, were divided into 6 groups. The turbines were contaminated with bacterial suspension. Streptococcus mutans, Staphilococcus aureus and Neisseria SP were the first microbial groups. Pseudomonas aruginosa was the second microbial group and Bacillus subtilis spore
was the third microbial group. After 5 minutes, three contaminated groups were placed in Deconex53 plus 2% solution for 15 minutes. Three other groups after contamination were sprayed with Deconex soiar sept spray for 2 minutes. Then the samples were placed in TSB culture and after 24 hours incubation at 37°, the samples were transmitted on blood agar solid culture for bacterial viability observation. The results were observed after 24 hours incubation. Proportional test with normal distribution was used for data analysis.
Results: The Deconex 53 plus had 85% disinfectant activity on the first microbial group, 10% on the second microbial group and 100% on the third microbial group. Also the solarsept spray had 30% disinfectant activity on the first microbial group and 15% on the third micribial group . The solarsept spray had no bactericidal effect on turbines contaminated by the second microbial group. The results proved that the disinfectant effects of Deconex 53 plus solution for 15 minutes were significantly better than the solarsept spray for 10 minutes. The Deconex solution and the solarsept spray showed 65% and 15% negative growth, respectively. Based on the elimination of all spores, Deconex 53 plus has great sporcidal activity.
Conclusion: These disinfectants should not be considered as suitable substitutes for sterilization with
autoclave.
Full-Text [PDF 582 kb]   (1858 Downloads)    
Type of Study: Research | Subject: general
Published: 2013/09/1

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb