Volume 26, Issue 4 (1-2014)                   jdm 2014, 26(4): 251-261 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Sadighpour L, Mir Mohammad Rezaei S, Jalali H, Rashtak S. Comparison of the microtensile bond strength of different composite core materials and bonding systems to a fiber post (DT Light). jdm 2014; 26 (4) :251-261
URL: http://jdm.tums.ac.ir/article-1-5093-en.html
Abstract:   (6150 Views)

  Background and Aims: Retention and stability of the post and core system is the key factor for success of final restoration . The aim of this study was to evaluate the microtensile bond strength of the different composite core materials and bonding systems to a fiber post.

  Materials and Methods: To evaluate the bond strength of the composite resins to a fiber post ( DT light post) 60 posts were divided into six groups : group A: Heliomolar Flow + Seal Bond, group B: Heliomolar Flow + SE Bond , group C: Valux Plus + Seal Bond , group D: Valux Plus + SE Bond , group E: Corecem + Seal Bond, group F: Corecem + SE Bond. All samples were thermocycled for 5000 cycles (5-55 0C) and cut into four bars for the microtensile bond strength test. Failure modes were identified using a stereomicroscope. Data were analysed using One-way ANOVA and Tukey HSD post hoc test (P<0.05).

  Results: The interaction between composite resin materials and bonding systems were positive. The conventional hybrid composite (Valux Plus) had significantly higher bond strength compared with the core specific flowable composite (Corecem) when Seal Bond was applied as bonding agent (P<0.05). However, when SE Bond was utilized hybrid composite demonstrated significantly lower bond strength than that of other two groups (P<0.05).

  Conclusion: The performance of a particular composite is affected by the bonding system that is applied. A single composite resin may have different bond strength when combined with different bonding system.

Full-Text [PDF 1042 kb]   (2815 Downloads)    
Type of Study: Research | Subject: general
Received: 2013/05/2 | Accepted: 2013/12/15 | Published: 2014/01/15

Add your comments about this article : Your username or Email:
CAPTCHA

Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb