Volume 30, Issue 1 (6-2017)                   jdm 2017, 30(1): 4-11 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Zeighami S, Siadat H, Alikhasi M, Saeidi Z. A comparison of full arch and sectional impression trays on the accuracy of impressions in angulated implants. jdm 2017; 30 (1) :4-11
URL: http://jdm.tums.ac.ir/article-1-5608-en.html
1- Assistant Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Dental Implant Research Center Dentistry Research, Tehran University of Medical Sciences, Tehran, Iran
2- Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Dental Implant Research Center, Dentistry Research, Tehran University of Medical Sciences, Tehran, Iran
3- Associate Professor, Department of Prosthodontics, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran; Member of Dental Implant Research Center, Dentistry Research, Tehran University of Medical Sciences, Tehran, Iran
4- Assistant Professor, Department of Prosthodontics, School of Dentistry, Kerman University of Medical Sciences, Kerman, Iran
Abstract:   (4794 Views)

Background and Aims: Taking impression from angulated implants has always been a great challenge in clinic. In this regard, studies on sectional trays are very few. The aim of this study was to evaluate and compare the dimensional and angular accuracy of impressions using full arch and sectional trays.

Materials and Methods: Four implants (4.3 × 12 mm) (Implantium, Dentium) were placed in the first premolar and molar regions of a Kennedy class I mandibular acrylic model with 30° lingual angulation. Twenty open special trays (Full arch & Sectional) were made on the primary cast. The impressions were taken using vinyl polysiloxane (VPS) and were poured with type IV dental stone. The coordinate measuring machine (CMM) was used to measure the dimensional (Z, Y, X) and angular (θ) coordinates of implants. The data were analyzed using and t-test and SPSS 22. Software.

Results: The type of tray had no significant effect on the dimensional accuracy in X, Y and Z axes (P>0.05) and total linear displacement (r); However, it significantly affected the angular accuracy (∆q) (P<0.05).

Conclusion: Sectional tray yields less rotational displacement in impressions made of angulated implants.

Full-Text [PDF 627 kb]   (1801 Downloads)    
Type of Study: Research | Subject: general
Received: 2017/06/11 | Accepted: 2017/06/11 | Published: 2017/06/11

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb