Volume 32, Issue 2 (10-2019)                   jdm 2019, 32(2): 83-91 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Mosavat F, Bashizadeh Fakhar H, Kharrazi Fard M J, Malekpour Estalaki F. Accuracy comparison of CBCT scan and radiography with two different horzental angle in vertical root fracture detection of endodontically treated teeth. jdm 2019; 32 (2) :83-91
URL: http://jdm.tums.ac.ir/article-1-5898-en.html
1- Assistant Professor, Department of Oral and Maxillofacial Radiology, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
2- Dental Student, School of Dentistry, Tehran University of Medical Sciences, Tehran, Iran
Abstract:   (4289 Views)

Background and Aims: Accurate diagnosis of vertical root fracture (VRF) is a fundamental importance in endodontics. Because of poor prognosis of VRF, digital radiographs with two horizontal angles have limitations in VRF detection. Also, Gutta-percha can produce artifacts that impair CBCT scan accuracy. The aim of this study was to compare accuracy of CBCT and digital radiography system in vertical root fracture in endodentically treated teeth.
Materials and Methods: In this study, 60 endodentically treated single teeth were selected and randomly coded. The teeth were divided into two groups: 30 with induced root fracture and 30 with no fracture. CBCT scan and digital radiographs with two horizontal angles with a difference of fifteen degrees for all teeth were performed. Two observers assessed the CBCT images and digital radiographies for presence of VRF. The statistical analysis used in this study was Weighted Kappa.
Results: CBCT had the highest sensivity (75.8) and specificity (90). Digital radiography with 68.3 sensitivity and 79.1 specificity were not as efficient as CBCT (P<0.05).
Conclusion: According to this study, the accuracy of CBCT seems to be higher than that of digital radiography in detecting VRF and provides the most reliable data in comparison of digital radiography.
Full-Text [PDF 607 kb]   (1741 Downloads)    
Type of Study: Research | Subject: general
Received: 2019/10/16 | Accepted: 2019/10/16 | Published: 2019/10/16

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and Permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by: Yektaweb