Volume 78, Issue 4 (July 2020)                   Tehran Univ Med J 2020, 78(4): 255-259 | Back to browse issues page

XML Persian Abstract Print


Download citation:
BibTeX | RIS | EndNote | Medlars | ProCite | Reference Manager | RefWorks
Send citation to:

Rai A, Amiri S, Sobhiyeh M. The experience use of drug-coated & non drug-coated balloons in arteriovenous fistula at a six months period: brief report. Tehran Univ Med J 2020; 78 (4) :255-259
URL: http://tumj.tums.ac.ir/article-1-10541-en.html
1- Department of Cardiology, Faculty of Medicine, Imam Ali Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran.
2- Department of General Surgery, Faculty of Medicine, Imam Reza Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran.
3- Department of Vascular & Endovascular Surgery, Faculty of Medicine, Clinical Research Development Center, Imam Reza Hospital, Kermanshah University of Medical Sciences, Kermanshah, Iran. , mreza.sobhiyeh@yahoo.com
Abstract:   (1919 Views)
Background: The ineffectiveness of hemodialysis fistulas causes high costs and increases mortality and morbidity rates. The efficacy of drug-coated balloon and nondrug-coated balloon in dysfunctional arteriovenous Fistula was evaluated over six month period.
Methods: In this randomized clinical trial, a total of a total of 50 hemodialysis patients who referred to Imam Reza Hospital in Kermanshah for failing of arteriovenous fistula in 2018 year, were randomly divided into two separate groups of drug-coated balloon angioplasty and non-drug coated balloon angioplasty. All of these procedures were done with the same surgeon. Patients were followed-up for 6 months. Variables and data of patients like age, gender, diabetes mellitus, hypertension, and location of arteriovenous fistula were documented and analyzed by SPSS software, version 21 (SPSS Inc., Chicago, IL, USA) using statistical tests. T-test and chi-square test were used for data analysis and the significance level was considered less than 0.05.
Results: The success rate of drug-coated balloon angioplasty versus plain balloon angioplasty in the efficacy of arteriovenous fistulas increased significantly (19 vs. 6 and 13 vs. 12, respectively, P<0.05). There is also a significant relationship between age and diabetes over the lifetime of the arteriovenous fistula. According to results, the efficacy of arteriovenous fistula in the elderly patients (>65 years) and the diabetes mellitus patients were lower than other risk factors causing end-stage renal disease.
Conclusion: According to the results of this study, the use of drug-coated balloons rather than non drug-coated balloon is more effective in the efficiency of arteriovenous artery fistula.
Full-Text [PDF 321 kb]   (562 Downloads)    
Type of Study: Original Article |

Add your comments about this article : Your username or Email:
CAPTCHA

Send email to the article author


Rights and permissions
Creative Commons License This work is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License.

© 2024 , Tehran University of Medical Sciences, CC BY-NC 4.0

Designed & Developed by : Yektaweb