Kazemi Bidhendi F, Mohammadi Basir M, Bagher Rezvani M, Khodabakhsh A, Labbaf H, Fahimi M A. Evaluating and comparing the effect of two liquid polishes on the polish retention of two nanocomposites. jdm 2022; 35 : 1
URL:
http://jdm.tums.ac.ir/article-1-6060-en.html
1- Dentist, School of Dentistry, Shahed University, Tehran, Iran
2- Associate Professor, Department of Restorative Dentistry, School of Dentistry, Shahed University, Tehran, Iran
3- Post-Graduate Student, Department of Restorative Dentistry, School of Dentistry, Shahed University, Tehran, Iran
4- Assistant Professor, Department of Endodontics, School of Dentistry, Shahed University, Tehran, Iran
5- Post-Graduate Student, Department of Orthodentics, School of Dentistry, Islamic Azad University, Isfahan (Khorasgan) Branch, Isfahan, Iran
Abstract: (1394 Views)
Background and Aims: Finishing and polishing of composites is a critical step influencing the clinical service of restorations. The aim of this article was to evaluate and compare the effect of two liquid polishes on the polish retention of two nanocomposites.
Materials and Methods: Eighty standardized disk-shaped specimens (4×2 mm) were prepared from two nanocomposites (n=40), including one nano-filled composite (Filtek Z350 XT-3M ESPE, USA) and one nano-hybrid composite (Aelite Aesthetic Enamel-Bisco, Inc. Schaumburg, USA). The specimens were randomly divided into 4 subgroups (n=10) based on the method of finishing (F) and polishing (P) procedures: M: as control, polymerized under Mylar strip; S: finish and polish with a sequence of Sof-Lex discs (3M ESPE, USA); SP: finish and polish with Sof-Lex discs and use of Permaseal liquid polish (Ultradent products, Inc. USA); SB: finish and polish with Sof-Lex discs and use of Biscover liquid polish (Bisco, Inc. Schaumburg, USA). The specimens were undergone pH cycling and brushing machine and then, the average surface roughness (Ra) and average profile changes along the desired area (Rz) of the specimens were determined with profilometer instrument. Two-way and one-way analysis of variance (ANOVA) was used to compare the mean of surface roughness. Then, Tukey test was used to identify the groups responsible for the difference and t-test was used to compare the mean of surface roughness.
Results: The type of composite and the method of polishing procedure had no effect on the mean Ra (P=0.733) but it had significant effect on Rz1 factor (P=0.025).
Conclusion: Using liquid polish after polishing discs had no effect on the polish retention of nanocomposites.
Article number: 1
Type of Study:
Applicable |
Subject:
operative dentistry Received: 2021/05/22 | Accepted: 2022/05/31 | Published: 2022/05/31